Fire Alarm Training Podcast

Fire Alarm Training Podcast artwork

8 Mistakes Every Electrician Makes When Installing Fire Alarm Systems (and How to Avoid Them)

Nov 27, 202510 hr 6 minAudioEpisode 39
ShareXLinkedInFacebookWhatsAppEmail

Episode Summary In this episode, Anthony T. Richardson shares the eight most common mistakes electricians make when installing fire alarm systems and how to avoid them. Drawing on over 25 years of experience designing and servicing systems across New York City, Anthony breaks down real-world examples, code violations, and costly oversights that can lead to inspection failures, wasted time, or safety risks. Whether you’re a licensed technician, an aspiring fire alarm installer, or a general contractor, this episode will help you master compliance, wiring standards, and life safety best practices. Key Takeaways 🔧 Why filing and permitting delays derail most projects ⚡ The right way to choose fire alarm cable types and gauges 🧠 How to prevent bad wiring and cross-circuit mistakes 📏 Proper device spacing and mounting heights for compliance ✅ The importance of testing every circuit and signal before inspection 🗂️ Why as-built drawings are crucial for final approval 🚫 The legal and financial risks of working without a license Resources Mentioned Join the Fire Alarm Business Blueprint Learn how to start, scale, and license your fire alarm business the right way. Free Fire Alarm Training Center Access free resources to improve your technical skills and get certified.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

now I've been installing fire alarm systems since the late 1900s and I know what you're thinking to yourself 19 but that's a long time ago but anyway that's over 25 years of me installing designing and servicing fire alarm systems in one of the most craziest cities and that's New York City I've worked in New York City schools New York City train stations where all the rats are New York City detention centers animal hospitals you name it I've done so many installs around the city and I've seen so many mistakes that electricians have made while installing and still I constantly get calls to fix installs

by licensed electricians technicians who just don't care and also unlicensed professional who just got a quick job that they trying to do on a fire alarm system so today I'm gonna go over the eight most common mistakes I see on fire alarm installations so you can avoid them so that way you don't fail inspection you don't lose time and ultimately put lives at risk we dead serious about what we do right so let's jump straight into it so the first mistake I see is not understanding the filing requirements it seems as if every project I get

they only concern with the project timeline when is the builder gonna be finished how quickly are we gonna be able to get the walls up as soon as I get the fire alarm drawings from their architect not even from a licensed engineer they just have a preliminary design that I can base my price upon I still have to get that over to my engineer West Autocad drawings this filing process can take up to 10 weeks most times 12 weeks to actually get the full permit to actually install the fire alarm system so before we could pull any wire it's actually 12 to 15 weeks

before we could actually do anything and a lot of times most contractors most general contractors do not consider the timeline when it comes to a fire alarm installation mistake No. 2 in this one I see constantly in the field not using the proper fire alarm cables no matter where you are in the state you have to use power limited fire alarm cables according to Article 7 60 the cable rating must be rated at 300 volts you must have the fire alarm markings on the cables if it's a power limited fire alarm cable as if it's a non power limited fire alarm cable

you must use the correct cable gauge no matter the distance if you're gonna be using 16 or rather 14 you need to know what circuits you're gonna be using this cable for you don't wanna intermingle the cables you don't wanna use 14 as supplying power and supply that to a data circuit that will disrupt the whole loop possibly blow out the CPU so you don't wanna cross your wiring you wanna follow the plans as the engineer had designed the shop drawings use the wiring that is designed to be used at sort of plans that have been approved by the fire department you should have no problems using the right cable

I understand that some manufacturers may make a cheaper brand of cable and you're trying to cut some corners and save some money but buy the right fire alarm cable charge the right price so that way the cable actually pays for itself and mistake number three pisses me off a lot and that's bad wiring some electricians out there like to use the 4 conductor where you have the red black the green and the white or sometimes the green and the yellow they sometimes get those confused as if they're wiring up high voltage circuits and they put in systems in series when actually these systems need to be ran in parallel I've seen so many installs

where we have wires coming into a junction box and then it's a star topology right after that one is trying to jump into one room one is trying to jump into another smoke one is trying to jump into another that is not how you wire up a fire alarm system it's not a series parallel circuit it is a parallel circuit or if you're hooking up a couple of things onto one module then it could actually be a series circuit but each wire should be ran in and out to each one of those devices so when you're coming into a junction box that junction box should be big enough or you should have the thought pattern

of how you should have your boxes for you to run as many cables as you need to go in and out of each of every fire alarm device and then either you're gonna come back to the panel or Class a circuit or it's gonna be at the end of the line at the last device that you ran that wire on so it's best that my suggestion you use one wire for data one wire for the horns and strobes if you're using a speaker circuit make sure if that speaker circuit needs to have a shielded cable make sure it's one wire for that as well if so if you're running four conductive cables

just make sure you pay attention to how you actually gonna run your cables it is a smart idea it could be but if you're not doing your ins and outs correctly you're messing up the wiring for the system so 16 for data 14 for 24 volts 14 for the horn strobes if you're looking to elevate your fire alarm skills I have a free training this is my way of giving back to all the technicians cause when I was coming up I had nobody to show me how to do it so for all the newbies that's coming up that's trying to learn how to get better at fire alarm there's a free training center for you make sure you click the link and if there's anything specific that you want me to do

leave it in the comments we could chop it up I'll let you know if I could do it or not and I'll do that video so that way I can help you and anybody else that may have that same question alright fire long training center link in description mistake No. 4 improper device spacing it's important that we install the devices in the exact location that it says on the plans I know a lot of times when construction go along there's lights in the way there may be plumbing there may be obstacles in the way it is your job to best place smoke detector in the most nearest spot that is designed for the plans

you shouldn't have a smoke detector as soon as you walk into the door right there above on the ceiling it should be centered in the room and if it's multiple smoke detectors they should all be spaced with between each other space from either sides of the wall so that way it fills up the room with Protection the right way and if you're mounting horn strobes or if you're mounting Pulse Station AFF means above the finished floor and I know a lot of times our constructions when we're walking across these floors they may not be finished so it's your job to know what the level of the finished floor is so when you actually mount these devices you

your mountain pole stations at 48 to 54 inches to the actuator your mountain horn stoves 80 inches to 96 inches to the lens to the actual strobe light so that way you have proper device mounting you wanna always make sure you install these devices correctly you wanna think life safety mistake No. 5 no functional testing after you install the fire alarm system you may test a few devices but not the whole entire system you must verify each and every device working at the fire alarm control panel

and also verify that these signals are going to the central station I know sometimes you may store relay and be like I know it's designed to go off when the system goes into alarm and you can write the program and things like that but without verifying we don't just wanna know we know that it will work but you have to verify take a video take a picture so that way you know mentally that this has been done a lot of times I see when we get to the final inspection things haven't been tested the water flows haven't been tested meaning that the water has not been ran by a physical plumber

the AC hasn't been tested they know the fire alarm the label shut off but they may have it tied to the wrong circuit or they're not properly shutting down the AC system so when you test these things when you install the system you could determine these faults fix them correct them so when it's time for the inspection you don't look crazy you wanna make sure when the fire department comes your system is 100% test you got all the confidence in the world that that smoke detector on the first floor electrical closet is gonna report to the central station saying the first floor electrical closet and it's gonna be an alarm signal the fire department's gonna show up

and mistake No. 6 is poor panel termination we don't wanna wire up the fire alarm panel sloppy we want our wires dressed up accordingly going in 90 degree angles so that way we can dress our fire alarm panels up neatly they may be a bunch of wires coming in through different pipes and connectors it is your job to tighten them up with some tie wraps there are hooks in the back of the panel hooks on the side of the panel so that way you can dress the wires up strip the wires back accordingly not too much just enough to fit under the screw you don't need no copper hanging out causing any accidental troubles and alarms

or ground faults on the system so you wanna be cautious you wanna be neat and you wanna be detailed when you're doing your systems take a little pride and make sure you do it right the first time'cause people come behind you and look and be like that's some good work right there and that's what I like to do mistake No. 7 is not having a proper as built drawing as you install the fire alarm system there may have been some changes from the original design it is your job to report that back to the fire alarm company so they can get their engineers you actually make those adjustments on the plans and also the as built riser diagram

so when it's time for the final inspection you will have your riser diagram mounted next to the fire alarm control panel and 11 by 17 frame with a stamp by the engineer and also stamp by the electrician a secondary copy will be given to the fire department so they can have for their record so they can know the type of system that is actually installed in that building and mistake No. 8 this is the absolute worst and this is working without a license I know there are a bunch of unlicensed contractors out there that is putting in fire alarm systems it may not be in New York City because the rules are a little bit strict it may be even some project manager

or maybe be a building manager just trying to get a security guy hey could you just install this smoke detector or run this wire or could you just look at this over here no you don't need to do none of that as long if you're not licensed you should not be touching a fire alarm system this is a life safety device and anything that you do as an unlicensed contractor for yourself in liability is either ten or fifteen thousand dollars of a fine that you're gonna have to pay for touching a smoke detector without a license so hire a licensed contractor that could actually perform form the work that you need to do pay the price that the actual contractor is paying

because they are licensed they are specialized in that position to actually fix that problem you was able to do it then you would be doing it there will be no licenses there will be no rules no regulations so make sure you hire the proper contractor or the right person for the right job if you're serious about installing fire alarm systems the right way the first time or trying to get your fire alarm license getting yourself nice and certified or even learn how to start and grow a fire alarm business click the link in my description to join a fire alarm business blueprint we have all the tools necessary there to make you either a better fire alarm technician

or we're gonna transform you from a tech to a CEO join a fire alarm business blueprint today and if you wanna learn how to read fire alarm drawings like a pro then watch this next video that's gonna pop on the screen here so make sure you subscribe so you can transform yourself to a tech to a CEO fire alarm expert out peace

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Don’t Start Your Retrofit Until You Do This

    Oct 22, 20261 hr 11 minAudio

    Cheat Sheets https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a71b6407f2cbe4ea1122.pdf https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a6d03dbd5f2bbbe14ddc.pdf...

    Credit the people on this episode

  2. Why Electricians Fail Fire Alarm Inspections (And How to Fix It)

    Oct 15, 202618 minAudio

    Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a92a72e0914f11215011369.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode

  3. Don’t Waste Money On The 81-Hour Course Until You See This

    Oct 11, 20264 minAudio

    NYS 81 Hour Fire Alarm Training https://nysfirealarmlicensecourse.secureitsecurities.io/ Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode

  4. EST3 Programming: How to Configure a Fan Restart Switch

    Sep 17, 20263 minAudio

    Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon...

    Credit the people on this episode

  5. This EST3 Programming Mistake Can Send EVAC to the Wrong Floor

    Sep 15, 202624 minAudio

    Evac Rule Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a8f6a30d1afbd2cbcbfbcc8.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode