Cheat Sheets https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a71b6407f2cbe4ea1122.pdf https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a6d03dbd5f2bbbe14ddc.pdf https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a6d06407f2cbe4ea0c23.pdf NYS 81 Hour Fire Alarm Training https://nysfirealarmlicensecourse.secureitsecurities.io/ Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon https://www.amazon.com/dp/B0GQ5259GY NICET Clarity Bundle https://portal.secureitsecurities.io/courses/offers/f4a10f66-4311-49f5-9906-022de3ab310d Practice for your NICET Exam https://quizlet.com/join/t2hyD9xaN?i=6sn3ll&x=1bqt Create your own unique offer for free with the Offer Architect https://offerarchitect.secureitsecurities.io/free-architect Fire Alarm Business Blueprint eBook Download https://ebook.secureitsecurities.io/fabb-ebook Send us your fire alarm questions info@secureitsecurities.com Zoho One https://go.zoho.com/LwT Live Events https://firealarmtraining.secureitsecurities.io/live-events Virtual Business Office https://alliancevirtualoffices.referralrock.com/l/ANTHONYRIC61/ Master the fire alarm retrofit process with this 6-step framework. Plan your project correctly before you touch any wire. This walkthrough outlines a methodical approach to replacing fire alarm systems, covering everything from the initial site survey to final documentation. It is designed for technicians who need a reliable system design strategy to avoid costly errors and delays when upgrading older hardware. We detail the full lifecycle of a panel swap, including the assessment, code review, and installation phases. Following these steps ensures your next fire alarm panel changeover meets all safety standards and operational requirements. You will learn how to manage the entire commissioning process with confidence. Subscribe for weekly fire system programming tutorials, and comment below if you want to see a walkthrough on specific alarm panel hardware next. 0:00 The Reality of Fire Alarm Retrofits 1:15 The Danger of Dangerous Assumptions 8:46 Planning for the Big Domino 11:45 The Six-Step Retrofit Framework 21:47 Code Compliance and Authority Requirements 37:53 Installation and Professional Standards 40:51 Panel Changeover and Programming 46:01 Final Testing and Documentation #FireAlarmBusiness #StartAFireAlarmCompany #FireAlarmTechnician #ElectricianBusiness #SkilledTradesSuccess #ServiceBusinessStartup #FireAlarmTraining #JackAndMaster #SchoolsOfSkills #FromTechToBoss #TradesToEntrepreneur #FireAlarmBlueprint #BusinessForTechnicians #AlarmSystemBusiness #LowVoltageLife #TechToCEO #StartYourBusiness #EntrepreneurTraining #FireLifeSafetyBusiness #ContractorBusinessGrowth
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Chapters
The Reality of Fire Alarm Retrofits
The Danger of Dangerous Assumptions
Planning for the Big Domino
The Six-Step Retrofit Framework
Code Compliance and Authority Requirements
Installation and Professional Standards
Panel Changeover and Programming
Final Testing and Documentation
Transcript
From the show. Tap a time to play from there.
Today we're going to be going over a fire alarm retrofit. This is actually a six-step framework we use anytime we have to replace any type of fire alarm panel switching from one manufacturer to the next. So this is all this is what we do all the assessments and everything that we do before we do so these are all the steps that we're going to take before we touch any wire. Right? This is going to be a live train.
This training is brought to you by the fire alarm expert. My name is Anthony Richardson and I am the president of Secure Securities Corp. We are a fire alarm company out in New York City. We are a licensed fire alarm company out here in New York City and we also teach the 81-hour course for you to get your New York State license. I'll be going live every two weeks. So, you can join me on the live. You can ask the questions, you can send us some DMs, however you want to get in touch to shoot your questions and we'll try to do our best to answer these questions. But
if you join it live, then you'll be able to, you know, shoot your questions and get your answers right away. Now, believe it or not, most retrofit failures happen before the installation even start. Now, let me explain to you why. It is not because the tech didn't know how to wire the system, nor is it because they bought the wrong It is not because the tech didn't know how to wire
the system. It is not because the tech didn't wire the system, nor did the salesman buy the right panel. It's because everybody is assuming that things is actually working when they're not. [laughter]
I've done a lot of installations, modifications, and retrofits throughout the years, and I'm explaining you why retrofits go wrong. The first assumption is thinking that the existing wiring is reusable. Now, in most cases, some wiring can be used, but you have to always have some type of a contingency just in case you may have to replace a bunch of cable cuz a lot of times you don't know what other installers are do. You may find you may find splice boxes in areas where a bunch
of wires is at because they had to get the job done. So, you have to make sure that 100% all the wiring is good. And the second assumption is you're assuming that because this system has an approved stamp. It was approved by the fire department that this system was installed correctly. You don't know what these people had. You don't know what these installers at that particular time had to go through to make this system work. A lot of people in most cases
in most cases things change. So, they may have to rerun some wires. They may got lazy. They may have. In some cases, you may come across a system that you're retrofitting and everything is thh.
Now, you have to put fire alarm wire throughout the whole entire building. So, you want to make sure that you know exactly what the existing wiring is. If there's any splice boxes, if there was any damages back in in the past, some water damage or anything like that, you want to make sure you understand what is going on with this particular system before you start changing out anything. And the last assumption is thinking that you could just slap a panel in and it's just going to be done. One and done.
None. No, nothing is one and done. Even if you're working with the same manufacturer and everything is backwards compatible, there's still some things you're going to have to do to make sure that this can work. Now, these assumptions can cost time, money, and failed inspection. This is each and every time. So, you want to make sure you don't have none of these assumptions and you understand what system that you're actually going to be replacing, what the wiring is, what the manufacturers, what the wiring is, whatever your manufacturer is, you want to make sure that the panel and the device is all
matched together. So, what is tonight about? If you're retrofitting a fire alarm system or about to bid your first fire alarm retrofit job, this is for you. Over the next 60 minutes, you'll learn exactly the six-step framework profession. You'll learn exact You'll learn the exact six-step framework I use
before I touch any wire on an existing fire alarm system. Now, you don't need years of any type of fire alarm experience. All you need is the right system and none of these assumptions. So once again, my name is Anthony Richardson. I've been in the business for over 20 years. I have an active fire alarm company named Secured Security
Corp where we install fire alarm and security systems in New York City. We work a lot with government clients. We have commercial clients and we also have residential clients where we sell our residential burglar alarm and our residential security systems or we sell our commercial fire alarm products for our government clients or also for our commercial security clients as well.
I created a course called the fire alarm business blueprint because in my mind I like to think vertical. So within the fire alarm business blueprint, this is going to take you from step zero all the way to step 100 and learning how to start and operate and grow a fire alarm business. And actually going through the fire alarm business blueprint will get you 50% off the 81-hour New York State course. So you'll get to learn fire alarm, you get to learn the business, and you get to learn how to get your license all under one umbrella. And it's
always continuing education, and I don't leave you after the first year. So once you get licensed and start conducting business, we will conduct business together, and I will show you all the steps that you need to take to make money in your fire alarm business. So, who is this training for? This training is for working fire alarm technicians, contractors looking to bid out retrofit jobs, and business owners looking for fire alarm businesses or fire alarm companies who's looking to do their or
business owners that's looking for a fire alarm company so they can get their work done within their properties. Now, this is what I want you to walk away with tonight. Retrofit is not new construction. I want you to understand why retrofit is a fun fundamentally different type of work than actually doing a full install.
Most failures happen before the installation. And I want you to know exactly where the risk are and how to eliminate them before they even happen. Then I'm going to show you the six-step framework, the complete framework that I use each and every day before we do anything on a fire alarm system.
[cough] >> [clears throat] >> Let's talk about the big domino. Retrofitting a fire alarm system is not installation work. It's all about planning, engineering, what you need to understand about the code and mitigating your risk.
Understanding this concept is what separate texts who understand how to do the perfect retrofit. And understanding this concept separates a text who knows how understanding this concept separate texts who do retrofits well other than texts that get stuck on them.
Now, let's look at a quick comparison for new construction versus a retrofit. In a new construction, it's an empty shell. You have a blank slate. You have clean walls. You could run all new conduit within the walls. It's a completely empty structure with integrated. It's a completely empty structure for you to run your wires, run your conduit all inside of the walls, nice and neat. So, none of this is exposed. All you will see is the end device on a nice clean wall.
Now, when it come to a retrofit, this is a building that is occupied. It has people in there. There's people moving around. There's workers. You don't want to be lifting up ceiling tiles, drilling, dropping dust all on these people. So, you have to be able to work effectively in a retrofitted type of situation rather than a new construction. In a new construction, you can make all the mess you want, but you have to be a clean technician when you're doing a retrofit type of system.
[cough and clears throat] Now, understanding how this occupied environment changes everything about your plan cuz you're not going to be moving as fast as you would as you would be moving on a new construction. Now the professionals who succeed at retrofit Now the fire alarm techs who receive Now the fire alarm techs who succeed at retrofitting they follow a
plan a framework before they ever even open up the panel. They fully understand what it is they need to do before they start demoing anything. So now let's get into the six-step retrofit framework. The first one is the site survey. You want to assess the existing system in all of the conditions. Are there any troubles? Do
is it good phone lines? Is it a pipe going back straight to the phone line demog? You want to find out anything. Are there any splice boxes, hidden splice boxes, or any splice boxes that you actually know? Code review. You want to verify the regulations and authority requirements. You may have to update this system with whatever current codes it is to date that you're actually doing this retrofit. Then you have a system design. You want to define the architecture and device strategy. One for one replacement. Do this. Do the client want the system never do the
client want no downtime? So you have to do one for one replacement or you can do section by section depending on how this system is actually going to be designed to be installed. That is the engineer's job to relay that information all the way back down to the installer. Then you have the installation. This is the actual execution of you replacing the devices, the panel, running the pipe, the wire, and things that things of that nature. If it's a retrofit and they want a one for one replacement, you will usually mount the panel either next
to the existing fire alarm control panel or in a different room. And you will start running your new wires, running your new pipe, and as you start getting to areas where you have to install smokes, you're going to be live, you're going to be doing pretty much a live installation. It's going to be powered up, ready to be programmed. And as you install these smokes, we can program them and demo the existing system at the same time. Then it's the changeover. Once you have everything installed, everything replaced, everything demoed out, this is
time for you to start doing your final programming so you can do your final testing. Every every retrofit we do follow the same exact sequence. We don't skip any steps, especially the first three. Those are the most important that you want to make sure you tackle.
So, step one, site survey and system assessment. Before you touch a wire, you need to understand exactly what you're working with. This step is not optional. It's the foundation of everything that follows. Number one, this is the foundation of everything that follows. You want to know what the manufacturer is. You want to know how many devices there are. You want to know if there's any tabs on a loop controller. You want to know whatever system it is. I'm always thinking Edwards, but it doesn't matter the system that you're working
on. You want to know if the Knack circus has an ender line. You want to make sure that everything is good to go. So, you will have any type of you want to know that at least you're working with a working system and anything that you need to fix is within this budget that you have to fix. Cuz usually on a retrofit, more than likely, you're going to have to replace some wire, if not all of the wire. Depending on the type of system and depending on how old the system is, you may have to
replace all the wires. Especially if you come up to a system that you're retrofitting and has THA and it has THHN in, you know, so when you're doing your site survey, what are you looking for? Like I said, be ex.
So, step one, this is the site survey and system assessment. Before you touch a wire, you need to understand exactly what you're working with. This step is not optional. This is the foundation of everything that follows after. So, what does a site survey cover? Number one, you must know what the panel type is, the make, the model, the age of the current panel, how long has this panel been installed. You must know everything about this particular system. You don't know how to service it. You don't need need to be an expert on it,
but you need to understand what the make and model is. So that way you can first assess, okay, this is this particular system and we're using this system. It may be some extra things that you may have to do. You want to understand the devices. how many devices are installed, physically installed. Maybe there's extra devices that they could have masked down the road. Who knows? You want to know exactly how many devices are installed on this system. You can usually get that information from the previous test reports or if you're working with um the
client and they have the database or some somehow they they will know the client will know how many devices they have because they should have some type of test report um from the previous company. the wiring, the condition of the wiring, the gauge. You want to make sure that they're using rather if it's 16 or if you're using 18, whatever it is, you want to use the proper wire gauge for whatever circuit that you're running. So, you want to make sure that you have the right type of wire. And if you're in New York City, you understand that you
need different type of wire. You can't even use the same type of wire that everyone else use when it's come when it come to when it come to installing a fire alarm system. Now, depending on this system, this system may have been capable of driving a lot of horns and strobes. Who knows? You want to determine if you need to add any power supplies, any additional power
supplies for the type of strobes that you're going to be adding because you may have to add more devices depending on if you have to bring this particular system that you're retrofitting up to code.
>> [clears throat] >> And then there's monitoring. You want to understand how the system is being monitored. Are they using plain old phone lines or do they have some type of uh are they using plain old phone lines or they using a IP dialer some other type of external DAC? You need to understand this because you may have to rerun phone lines back to the demark or you may have to install an external communicator, run network to it and then run phone lines from the communicator to the fire alarm panel. So depending on what you would have to do, you need to understand
everything before you start running wires. Now let's talk about the dangers of assuming especially in step one. I don't want you to assume that the wire is reusable. I don't want you to assume that the old system was installed correctly. I do not want you to assume that you can just swap out the panel and devices and walk away. The real risk is many retrofit failures happen because someone tried to swap out a panel without checking field wiring or running proper calculations, especially
for the Knack circuits. The original installation often have code violations nobody caught for years, especially code changes over the years. So depending on what year this system was installed to the to the time that you're actually retrofitting, you're going to have to bring some you're going to have to bring this up to date. So you don't want to have any violations. You don't want to have any failed inspections. You want to understand exactly what you're doing the first time.
So remember inside of step one, what you're going to do is slow down at this step. This is going to save you later for the other steps. Especially save you in your pockets. Especially save you when it come to
So, a substep inside of step one is to slow down. This is going to save you later.
Now, step two is the code review and authority requirements. Any retrofit must comply with the current adopted fire codes and especially NFPA72 codes. This must be this step must happen before you commit to any design or any equipment, not after. What the code review must verify? One, it must verify the device spacing. You want to confirm that each detector that is installed is actually in the right
spacing, is actually in the right spot. You want to confirm that each device that is installed, especially a smoke heat or duct detector, pulse station, whatever it is, you want to make sure that that device meet the spacing requirements. You want to make sure your strobes have the proper candela rating, especially if you're putting them on a ceiling versus putting them on a wall, you're putting them in an area that's bigger, you're putting it in large areas, or if you're putting it down in corridors, you want to make sure you have the right candela
rating for your strobes and your audibility requirements. Rather, if you're using a voice system, you're retrofitting from a horn strobe to a voice system or you're just doing a plain old horn strobe system, you want to confirm that your DB levels is required for any of the spaces that you have these devices installed. Your pull station locations, you want to verify placements. You want to make sure that it's at the right height. You want to make sure that you have pull stations
every 200 feet. If you're in a corridor, you want to make sure that you have pull stations at every exit. You want to make sure that if there's an exit that's 40 ft wide, you have a pull station on both sides. You want to make sure that whatever you're replacing or whatever you're upgrading, retrofitting, you want to make sure that the system that you're putting in meets code. And then if there's any local AJ amendments, you want to identify any amendments that the fire department in your jurisdiction or if you're working for a government client, whomever the
AHJ is, you want to make sure that they have you want to ensure that if there are any amendments, you know what they are. Let's talk about the grandfathering trap. Once you modify a system, you may trigger full compliance with current code. What was grandfathered before may no longer be acceptable. So, you may
have a fire alarm control panel that you're retrofitting and one of the new codes is you got to have a smoke detector in that same room as the fire alarm control panel. So, what does that mean? you have to install or add a new smoke detector for this area because there's not one there. This is not a techn this is not a technicality. This is a job stopper. If you find it mid installation, you want to always verify with the AJ before you start.
A 10-minute phone call at step two can save you a week of rework at step six. Now step three, this is where we get into the system design and device strategy. This is all about the engineer. This is his work how he will design this system and then lay it down to the project manager or to the salesman or to the technician or to the
installer. However it gets you the system design and device strategy comes from the engineer. Now retrofit work requires smart design choices. You are not designing for an empty building. You are designing for you are designing around what already exists. That constraint changes every decision you make. So some of the principles in a retrofit design, you want to reuse the conduit
where you you want to reuse conduit where you can reuse conduit. If conduit is good, if there's a if this is an indoor application and all the conduit is good, then you good. you have a way or a path where you can run all of your cables without running new conduit. This saves you time. You make a little bit more money on the project. This minimizes damage because you protect the walls and ceilings. You don't have to redrill. You don't have to re
You don't have to redrill. You don't have to redrill the walls or any ceilings. You don't have to put any fire stop. All of that stuff is there already. You want to make sure that your devices are compatible, especially if you're doing a retrofit. If you're doing a retrofit, usually nine times out of 10, you have your own fire alarm manufacturer behind you. So, you're using your own system.
And regardless of what manufacturer you want and regardless of what fire alarm manufacturer you're working with, you should always have a clean change over because you understand your system and you should be because you understand your system and most importantly you understand fire alarm.
Now let's talk about addressable versus conventional retrofits. Why address why an addressable system is often the right choice? You have better diagnosis in existing buildings. It's easier to troubleshoot and is room for future expansions. The critical warning though, a poorly designed addressable system on a retrofit is harder is harder to troubleshoot than a conventional system that you had ever replaced. Design it first then commit to the equipment. So depending on your manufacturer, you
would already have this information at hand. So, here's some key takeaways for the first three steps. You want to make sure you do a site survey. You want to know exactly what you're walking into. Panel devices, how many splice boxes, fuse cutout, fuse disconnect, if they're going straight to the panel for electrical, if they're going straight to the electrical panels for power, or if they're using a fuse disconnect, whatever it is, you want to make sure you know everything on this system. Then
there's a code review. Do you have to add any additional devices? Is this current system that you're retrofit already up to code? If not, you have to bring it up to code. And three is the system design. The design around what exists, not around what is ideal? Now, let me ask you a question. Which of these first steps do most of you skip on a daily basis? The answer is usually definitely all of them because most
tests don't do engineering, but they should get the drawing. They understand what they need to do when they doing a retrofit. You should understand what the codes are currently and you should understand what type of system that you're working with or working on. Yo, if you So now, if you following along with any of this, give me a thumbs
up in the comments. Give me a thumbs up in the chat. Just let me know that you understand what's going on. If not, just shoot me a question so that way we can get these answers and get you clarity on what it is that you're confused about.
>> [cough] [clears throat]
>> the belief that holds text backs. Here's a belief that hold most technicians back. They have a false belief that retrofit work is only for experienced contractors or experienced tech tech. Here's some of the false belief that holds some of you technicians back. You have a false belief that you think this type of work is only for experienced technicians. It's really not. All you need to do is understand what the steps are. Once you
understand the concept, all you got to do after that is slow down and then get busy with the concept. No. This is something that hold most techs back. They have a false belief that retrofit or this type of work is only for the experienced technician. It's really not. It's only for It's really not. If you understand what the concepts
are, if you understand the steps that you need to take, all you got to do is slow down and go through the steps one at a time. What I'm trying to show you is that the framework is learnable. The structure and preparation creates the experience. So the tech who succeeds are the ones who slow down and understand what they're doing in each and every moment.
Let's talk about some professional skills. The first professional skill that you should master is slowing down at the right moments. You don't need to hesitate. You don't need to be deliberate, methodical. You want to assess before you commit to anything. Think before you act. If you don't know, you want to ask the AJ. You want to ask your fellow technicians, you want to ask your manager, you want to ask the engineer, you want to ask a person who has a higher nice set level, or you go to the
national fireproction.org and find out yourself. You want to document before you disconnect. You don't want to just go up in the building, start taking stuff out. You don't want to start doing that. You want to understand exactly what you're doing before you touch it. And this is not an optional thing. You want to test 100% everything before you
call the fire department to come in and verify your system. [cough]
Let me show you what this framework look like in action. [cough] >> [clears throat]
[clears throat] >> structure and preparation creates experience. Chaos with no clarity creates confusion. Remember that. Step four, this is the installation phase. This should be the easy part. This is where experience matters the most. But prep a mat, but your preparation will matter more. You have to be you have to be well prepared in order for you to actually perform the work that you're doing. So the work you
did in step one through three will determine whether step four goes smoothly or fall or fall apart. Now during the installation phase, you want to coordinate with management. You want to schedule the work if it have to be off hours or if you can't do the work during normal hours. Whatever the working hours are, you want to make sure you have that coordination with management or your PM. You want to label
before you disconnect. That's 100% the You want to label before you disconnect. This is the smartest thing you could ever do. You don't want to just start pulling wires off the circuits and then for and then forget what wire is for what. So you want to make sure you label each and every wire before you disconnect it, remove it, cut it, whatever. And you never leave anything unprotected. If the system must go offline, you need an approved firewatch, written authorization, not no handshake. So, if you're having a system that
you're actually installing in a large warehouse over 50,000 square ft and this system is not connected to the central station because of whatever the situation is, then yes, we're going to have to figure out how we going to get some firewatch in this building so that way they could man this building when it's unoccupied, when we're not working, so that way we can when it's unoccupied or when we're not working. [sighs] And you you and you never want to leave the system unprotected. So if the system must go offline with the central station, you have to hire a
firewatch. Now being professional is not an option. It's mandatory. You're someone
you're in someone's occupied building. The occupants trust that you know what you're doing. Your documentation and your process is what prove that. So professional is so you being professional when you're doing this retrofit is not about your appearance. It's about protecting the people that's inside the building while your work is being done.
Now we get into the panel change over and programming. This is the most technically demanding moment of the retrofit. You must work be One mistake here can create you hours of troubleshooting. So, just make sure you're paying attention when you wiring up the panel, when you're wiring up your devices, and when you actually programming the fire alarm system. Here's a sequence we follow. We transfer
one circuit at a time. We na We transfer one circuit at a time. I never transfer multiple circuits simultaneously. I don't want to be confused. I verified supervision at each transfer before we move to the next. So, I'm making sure that everything on this particular cable is good to go before I move on to the next circuit. Then we get into programming. Every address must be correct. Every label must be clear and understandable. We must have the documentation next to us,
the sequence of operations. Whatever we have to actually program this panel, we need to make sure that that information is 100% correct. And it also must match the sequence of operations. If we have door, if we have door release, fan shutdown, stair pressurization, whatever the functions are, we need to make sure that this system performed those functions.
So, I want to pause right here for a moment and talk about the school community. If you look into pass your night set one, two, three, or four, there I'm building out a whole entire community where we're going to have thousands I'm I'm literally not bsing you. thousands of videos for night. So if you want to brush up your skills, pass this night test, I need you to join the school community. We have I think I got about 20 videos there now for night set one. I'm actually building it out as
we go. Uh there you can catch me live. There you can catch me uh once a week. So that way we could actually go over how to prepare for the test, go over some practice questions, learn everything we need to learn to advance our career when it comes to being a fire alarm technician. And then we going to sprinkle a little bit of business in there, but it's going to be more give focus to you learning nice certification on all levels. All right, from fire alarm to also test and inspection. So you can follow that link in the
description. So, let's talk about the cost of rushing in step number five. One programming error is a failed inspection. There's no room for errors when it come to fire alarm. A failed inspection sends you back to the beginning. You don't want to do that. That's going to cost everybody money. The professional principle, slow is smooth, smooth is fast. Do it right at step five and six become straightforward after. Slow is smooth and smooth is fast. If
you do it right at steps five and six, everything becomes straightforward right after that. So don't rush step five. You spend twice as long at step six when you start troubleshooting the system, if you even need to. Now, sex.
Now, step six is the final stage. This is where you're going to perform 100. This is where you're going to perform 100% test of the system. Send all the signals to central station. This is where [snorts] you're going to make sure you have your documentation, your record of completion, your NFPA forms, whatever you need to fill out to say that this system was installed to code. That's what you're going to have. So before you call the fire department, every device must be tested. This is So before you call the fire department,
you want to make sure that every device is tested 100%. This is the final proof that your retrofit was actually done correctly. So you want to show up prepared for that final test. So the pre-insspec the pre-insspection test the pre-insspection testing checklist your audibility your audibility you you want to make sure if you're using horns that your horns have the correct dB levels.
If you're using speakers, you want to make sure that voice is clear. If you're using strobes for the strobes or for the horn strobes or for the speaker strobes, you want to make sure that these strobes are synced. If you have to add a sync module, if your system is not able to sync it straight from the circuit, you want to have a sync module. You want to make sure your candela rating is correct.
You want to test all your troubles in supervisories, your batteries, your phone lines, your AC, your tamper switches, any input modules that may be controlling dampers. If you have any monitor points, you want to make sure that all of this stuff actually work the way it's supposed to work. And then your central station, you want to confirm that all the signals that need to be sent over to the central station that they are receiving them correctly. It's labeled correctly. And you're going to send the fire department in the exact location that they need to go when that
when that system go into alarm. What do you need to have in the documentation? You need your asbuilt riser diagrams. This is exactly what you had physically installed. If you had made a change or moved a detector, you need to write that. You need to make that modification on the asbuilt. Submit that to the engineer so they can make the modification and send you back the
final asbuilt riser diagram and the final asbuilt drawings exactly as it is that you had installed it. You need your battery calculations, documented standby, alarm and load calculation times. You need your voltage drop calculations. You want these calculations pro prove that from the fire alarm control panel to the last device that every device in between will work. And you need your do and you need your device address list a complete list of all of the device addresses and
locations.
This is how you would submit your documentation package along with the PDFs of every device that you use, the manual for the fire alarm control panel, and This is how you will this is how you will this is how you will prepare your documentation package along with all the PDFs for every device that you use and also the the and also the main and also
the manual for the fire alarm control panel. Now, when it's time for inspection,
let's talk about what the inspectors look for. The inspectors don't want you to wait The inspectors don't want to wait for you to look for your paperwork. The inspectors don't want to The inspectors don't want to wait for you to look for your paperwork. You need to have that ready. You need to have that ready to go when the inspector get there. They also don't want to discover things that you should they also don't they also they should never discover things that you they should never discover things that you should have picked up in your pretest or along the
installation. You want to show up to the inspection complete, 100% ready, professional that this system is going to pass the first time. So, some key takeaways for steps four through six. Step four, the installation. You want to label 100% label everything before you disconnect any wire. You never leave the building
unprotected and you must have a written authorization for any system downtime. Step five, the panel changeover. You demo one circuit at a time. Your programming must match the full sequence of operations. Make sure that your inputs match with your outputs. Make sure that your elevators recall. Make sure your fan shut down. Make sure the functions are happening that's supposed to happen. And step six, testing and documentation.
Everything must be tested. Everything must be verified to the central station. And you must have all your paperwork ready at the final inspection. So, let's take a quick look at the complete six-step framework. You have step one, which is the site survey and system assessment. You want to know what you're walking into. Step two is the code review and authority requirements.
You want to verify with your AHJ before you start anything. Step three is the system design and device strategy. You want to design around what is existing. What is the current what is the current environment that you're actually going to be working in. And step four is the installation phase. You want to label before you disconnect. and you want to protect the occupants that you're actually working around. Step five is the panel changeover and programming, one circuit at a time. And
step six is testing and inspection. And step six is testing, inspection, and documentation. Every device must be tested, and you must have all of your paperwork for the final inspection. So understand that retrofit equals planning plus engineering plus cold knowledgement plus risk management. You must follow the sequence and the job
becomes manageable each and every time. >> [cough]
>> So now that you have the framework, let's look at some more advanced steps you can take. The retrofit. The retrofit. The retrofit framework is only one piece of a bigger system. Tonight's framework cover the technical side of the retrofit. Tonight's framework only covers the retro Tonight's framework only covers the technical side of the retrofit frame. Tonight's framework only covers the technical side of the retrofit. But if you're serious about turning your fire alarm skills into a business that
pays what you're worth, there's a complete system built exactly for that. I want to introduce you to you the fire alarm business blueprint. You have free
>> [snorts] >> Every two weeks we're going to be going either live or I have a pre-recorded video for training. Every two weeks I'm going to be going live. It's either going to be a pre-recorded video or me actually being there depending on the schedule. I'm very busy, but I'll try to get there as much as I can. But it will be some training there for either you learning fire alarm, some basic fire alarm training, advanced fire alarm training, programming training, night set training, or anything about the fire alarm business, or if you're trying to get your license. So, anything that I'm
doing within fire alarm is going to be within these trainings every two weeks. Now, the next session is October 7th, 2026. So, the seats fill up fast. So, if you register tonight, you already have your seat locked in for that date. And this is the link to the registration training. You can click on this link right here. It'll take you to the event. You can click on that link right there. It'll take you to the next page where you fill out your registration. Boom.
Bam. Bip. You get an email. You'll be locked in. [snorts] This is what I'm This is what I'm going to be doing versus what I'm not going to. But this is what I'm going to be doing on the live versus what I'm not going to be doing. So, the live is structured anywhere between 60 to 90 minute sessions. We're going to have
real topic, but on a specific blueprint topic. We're gonna have live Q&As's with me, replay access only for the registered attendee. So when you get the replay or once you register with us, you'll all you'll automatically be able to get the replay. So there's a site you'll be able to go back to to see all of the replays. So what it's not this is not a pitch. What it's not I'm not trying to pitch anything to you or do anything try to sell you anything. These are all
pre-recorded courses or paid programs. This is completely free. I'm not charging you anything for this. So, the same content each and every session. So, I'm here to help you advance your skills to the next level. However, if you want to do business with me, we can do business together. However, if you want to do business, I have courses. I have test prep. If however you do want to do business, I have test prep kits. I have courses. I have anything that you need to study for these nice set exams to get you to pass it the first time.
And don't forget, I do have a book called the Spark Series Pocket Edition. The book is selling out very, very fast. So, you can use code spark 5 to get you can use code spark 5 to get 5% off when you order the book. You can also find that link in the description below. So, here's some of the stuff we're going to be going over in the the live training. We're going to be going over business formation like what is an LLC,
corporation, escorp, things like that. How to get your EIN, business baking, business banking, the legal found, the legal foundation, every contractor need before doing the legal foundation. Every contractor need before you do any type of work. How to get your how to get your New York State fire alarm license. This is only specific to New York State, not no other state. However, if you are working in another state and you want to go through the program, you can still go through
the program and I will work with you to get the license within your state. Then it's insurance and bond. Insurance and bonding, the coverage types, how to get bonded as a new company, the bid, the performance bond, payment bonds, all of that stuff explained. Then we get into estimating and bidding site walkthrough, material takeoff, labor, profit margin, and how to price your jobs correctly.
Then we have some advanced modules where we learn about marketing and the next OS system, how you can automate your entire business. Then there's operations, working with subcontracting, scheduling, reoccurring services, documentations, client communications. Then there's the financial system, job costing, how do you pay yourself, tax structure, growth, capital, how to run your money correctly. Everything is a system. [cough]
[clears throat] [snorts] And here's what you get in every session. You get live Q&As's. If I'm there live, you we can definitely chop it up back and forth. It's a pre-recorded video. Just send me an email or leave your questions right there on the video and I'll get back to you. you have full replay access to watch all of the pre-recorded videos that we had did or even the live videos. It'll be one main site with all of that information, all of that training back on that site. And this is going to be a real peer network, real questions coming from real
text contractors at the same stage you're in right now. So now the full blueprint B. So that a full blueprint value to learn all of this business found the business formation the license road map insurance and bonding estimating marketing the Nexos automation system live Q&A for each and every session and tonight's retrofit framework is all 100%
And the retrofit framework is all 100% free. So who is this live training built for? It's built for the early stage technicians who never ever worked on a retrofit or never did a retrofit ever in their life. It's for the existing contractors who already have a company, but they're relying on word of mouth. You need the market monster and an XOS system to build a consistent lead
pipeline. And it's also for business owners who want to run their business without being on every job. Operations and financial systems modules are all built for you. So, you may be asking yourself, is this live training really free? 100%. As mayo say, 100%. You don't need a credit card. There's no trial period.
Once you register, all you got to pay is time and attention. You get real content. is 100% free because I want to show you the system before you ever spend a 100% free cuz I want to show you it's 100% free cuz I want to show you the system before you spend a single dollar. So now if any of these live sessions So
now if you find value in any of these live sessions that we actually go through and I know you and I know it will the fire alarm business blueprint goes a lot deeper but the live training can but the live training itself will cost you nothing. So, what will happen at the live training?
It's a structured 60 to 90 minute session covering specific parts of the fire alarm business blueprint. I'll teach you real content, take on a lot of questions and show and show you exactly how to apply what you learn for your business and your fire alarm career. Every session is going to be different and the registration gets you access to the replay if you can't make it on the live. So, I already have a company. Will this be right for me? The short answer is
yes. The live training covers both early stage businesses. The live training covers both early stage business building and growth systems for existing contractors. This is specifically for a business owner who's trying to get into the marketing but doesn't understand how to market his business using our proprietary system next automation. This session is built for contractors who already have a company and want to consistently build a lead pipeline instead of relying on word of
mouth. So, what is the fire alarm business blueprint? The blueprint is the full business system from forming your LLC through getting licensed, bonding, insured, and marketing your company. The live bi-weekly training delivers the content in increment sessions. The full
blueprint, the full program goes a whole lot deeper with templates, tools, and done for you support to tonight's registration to get your foot straight into the door. I work long hours. Can I watch the replay? Yes, 100%. Every session is pre-recorded or lively. Yes, 100%. Every session is either pre-recorded or I'll be there live. But regardless of how I show up, you will
have the replay on the site where you will be able to see all of the training that we do every two weeks. If retrofit is not my focus, is there still value in your lives? Absolutely. The retrofit framework is only one module. The live training covers licensing, bidding, marketing, bonding, the Nexos system, and all of the business operation that we do in a fire alarm comp and all of the business operations. So, whatever stage you're
at, whatever your focus is, there is a session that applies directly to where you are right now. So, the seats are limited. So, make sure you register tonight. These sessions fill up very fast. So when registration hits his capacity, the next session is in October. Registration tonight will So register tonight if you're thinking about it. So So make sure you register tonight and don't think about it. Don't wait until the next week and find out that the session is full. The seats fill
up very fast. So register the seats fill up very fast. So make sure the seats fill up very fast. So make sure you register now. This is one question I want you to ask yourself. What does the next retrofit job look like? What does the What does the next retrofit job look like if you walk in with a clear six-step process and a business behind you that is licensed, bonded, insured, and generating leads automatically?
That is what the fire alarm business blueprint builds. So, make sure you register for the next free live session. The fire alarm business blueprint is free. the bi-weekly live training 100% free. The next session is October 7th, 2026. So, make sure you register while the seats are available. It's hosted by me, Anthony Richardson, the fire alarm expert, Security Securities Corp. Free registration.
[gasps] Here's what the blueprint covers. This is what the full fire alarm business blueprint look like. You have your business formation teach you LLC's corp figure out what type of business structure is right for you EIN business bank accounts your license road map your license road map which is specific to New York state you get your license uh which is specific to New York state you learn about NISET and your local AJS insurance and bonding types of coverage bid bonds what are these things
estimating bidding labor material margin marketing, CRM, automation and leads, operations, sub, scheduling and service contracts, the financial system, job costing, owners pay and tax, live Q&As's, direct answers from me, replay access, recording sent 24 hours replay access. You have replay. You have un You have lifetime replay access to watch all of
the pre-recorded and live replay videos. So, every two weeks we go live. It's free real content. You learn license, insurance, bonding, marketing, the next system, and business operations. So, make sure you register now before the seats fill up. So, make sure you stay safe. Wire it clean.
So, make sure you stay safe and always wire it clean. You now have this. You now have the six-step retrofit framework. Use it on your next job and register for the next live session and see how it fits into the complete system for building a profitable fire alarm business. Remember, the next session is October 7th. Register now before the seats fill up. I'm Anthony Richardson, the fire alarm expert, president of Secured Securities Corp. And I'll catch you in the next video. Peace.
Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a92a72e0914f11215011369.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...
NYS 81 Hour Fire Alarm Training https://nysfirealarmlicensecourse.secureitsecurities.io/ Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...
Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon...
Evac Rule Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a8f6a30d1afbd2cbcbfbcc8.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...
Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon...