Skip to content
PodSubs
ShowsPeopleGuestsJobsNewsEvents
More
BlogPodCred
Menu
ShowsPeopleGuestsJobsNewsEventsBlogPodCredNetworksSign in
Join nowSign in
  • Shows
  • People
  • Jobs
  • News
  • More
    • Guests
    • Events
    • Blog
    • PodCred
    • Networks
    Join nowSign in

Fire Alarm Training Podcast

Fire Alarm Training Podcast artwork

How to Write EST3 Fire Alarm Rules Like a Pro

Sep 1, 20263 minAudio
ShareXLinkedInFacebookWhatsAppEmail

Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon https://www.amazon.com/dp/B0GQ5259GY NICET Clarity Bundle https://portal.secureitsecurities.io/courses/offers/f4a10f66-4311-49f5-9906-022de3ab310d Practice for your NICET Exam https://quizlet.com/join/t2hyD9xaN?i=6sn3ll&x=1bqt Create your own unique offer for free with the Offer Architect https://offerarchitect.secureitsecurities.io/free-architect Fire Alarm Business Blueprint eBook Download https://ebook.secureitsecurities.io/fabb-ebook Send us your fire alarm questions info@secureitsecurities.com Zoho One https://go.zoho.com/LwT Live Events https://firealarmtraining.secureitsecurities.io/live-events Virtual Business Office https://alliancevirtualoffices.referralrock.com/l/ANTHONYRIC61/ ➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖ Master alarm system configuration by learning how to set up specific rules within the software interface. See exactly how input qualifiers and output logic interact. This tutorial breaks down the software interface for managing alarm system configuration. It is designed for technicians and operators who need to understand how to correctly structure code for reliable performance. You will learn to navigate the input qualifiers and output side of the system to ensure your rules are functioning as intended. We focus on the practical implementation of essential programming tasks, such as setting up general alarms, fan restart sequences, and elevator recall auto functions. By understanding the syntax and separation of these commands, you can streamline your workflow and reduce errors during alarm programming. Subscribe for weekly automation rules tutorials, and comment below if you want to see a deep dive into specific input qualifier scenarios next. #FireAlarmBusiness #StartAFireAlarmCompany #FireAlarmTechnician #ElectricianBusiness #SkilledTradesSuccess #ServiceBusinessStartup #FireAlarmTraining #JackAndMaster #SchoolsOfSkills #FromTechToBoss #TradesToEntrepreneur #FireAlarmBlueprint #BusinessForTechnicians #AlarmSystemBusiness #LowVoltageLife #TechToCEO #StartYourBusiness #EntrepreneurTraining #FireLifeSafetyBusiness #ContractorBusinessGrowth

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

General alarm, this is your rule label. Every rule must have a label. You have your fan restart label, your fan restart LED, your elevator recall auto. So now let's look at it. If you see right here, we have semicolon. Now the semicolon separates your input side from your output side. And on your input side, you have some qualifiers that you can use. So for here, I know this may look a little confusing if you're watching this. So we have alarm, then we have I need you to help me out with this. I

don't know what this is called. So we have I'm going to just call this open and close, okay? So we're going to name this open and close. So we have open to open the input of that we're trying to activate, right? So alarm input, and I'm going to show you what L star actually means. Then we close that, and this is all syntax. If you don't have this syntax, you will get a rule error. So now we separate the input side after we give it all this information including the rule label. Now we have the output side. Now on the output side, we have a bunch of activations that we're trying to do. Now what's very important to keep

in mind is we have to know what we're turning on. We want to turn on the amp. These are all point types for these outputs. So we hit we want to turn on the amps. We want to turn on some CC1s, cuz if it was an amp, it'll say amp on. If it's just saying on, then either it's a module or coming straight from the panel. And then we're going to be disabling something. So how this actually work, you need to include all of these opens, cuz what you're telling the system is that, okay, amp on is the point type, and then here's the quotation open, not quotation, but here's the open guy, and then within

open and close guy, this is our device. This is what we're trying to control this particular point here. So this amp that is wherever it's at in the building is labeled, let's say fourth floor, but this star is representing all of the amps in the building. And I'll show you what that mean in a minute because you may be a little confused at the moment. All right, so we have inside of open and close, right? Inside of open and close is the actual device. And what is the device type? It is a amp. So, amp whatever floor, amp point type. Speaker

whatever floor, module on, all right? So, you need the open and close, and you also need this guy here. So, for every output that you want to activate, you need a comma. You need to separate it all by a comma, and you need to end it all with a semicolon. So, all of that syntax is needed. So, what it's doing here is alarm, any alarm pretty much, turn on the evac channel, turn on the speakers, all the speakers, all the evacs, turn on all the strobes, release all the doors, turn on like shut down all the fans, and disable the fan

restart switch. So, that way anytime the fan shut down, we're disabling this fan restart switch.

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Don’t Start Your Retrofit Until You Do This

    Oct 22, 20261 hr 11 minAudio

    Cheat Sheets https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a71b6407f2cbe4ea1122.pdf https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6ab7a6d03dbd5f2bbbe14ddc.pdf...

    Credit the people on this episode

  2. Why Electricians Fail Fire Alarm Inspections (And How to Fix It)

    Oct 15, 202618 minAudio

    Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a92a72e0914f11215011369.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode

  3. Don’t Waste Money On The 81-Hour Course Until You See This

    Oct 11, 20264 minAudio

    NYS 81 Hour Fire Alarm Training https://nysfirealarmlicensecourse.secureitsecurities.io/ Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode

  4. EST3 Programming: How to Configure a Fan Restart Switch

    Sep 17, 20263 minAudio

    Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course https://firealarmbusinessblueprint.secureitsecurities.io/fire-alarm-blueprint Spark Series Book on Amazon...

    Credit the people on this episode

  5. This EST3 Programming Mistake Can Send EVAC to the Wrong Floor

    Sep 15, 202624 minAudio

    Evac Rule Cheat Sheet https://assets.cdn.filesafe.space/JUeauqFFpAgQpPWQ1TsD/media/6a8f6a30d1afbd2cbcbfbcc8.pdf Spark Series Book https://pocketedition.secureitsecurities.io/pocket-optin-855933 Join The Course...

    Credit the people on this episode