Master The NEC | Episode 69 | 8 NEC Code Questions on GFCI, Service Disconnects and More

Jul 6, 202643 minAudio
ShareXLinkedInFacebookWhatsAppEmail

In this episode of Master The NEC Podcast, we continue our practical breakdown of important 2023 NEC and 2026 NEC electrical code topics that every electrician, electrical inspector, plans examiner, contractor, engineer, and electrical code professional should understand. This episode focuses on real-world National Electrical Code questions, common installation mistakes, and key changes in the 2026 NEC that impact residential, commercial, and limited-energy electrical systems.We discuss important NEC topics including transformer secondary conductors, dwelling service disconnects, emergency disconnect requirements, limited-energy systems, communications systems, readily accessible equipment, GFCI protection, surge protection, and working space around electrical equipment.Topics covered in this episode include: Transformer Secondary Conductors and the NEC Next-Size Rule 2026 NEC Service Disconnect and Emergency Disconnect Changes for One- and Two-Family Dwellings Chapter 8 Communications Systems and 2026 NEC Limited-Energy Reorganization Accessible vs Readily Accessible vs Within Sight in the NEC GFCI Protection for Dwelling Garages and Accessory Buildings GFCI Protection in Other Than Dwelling Units Under NEC 210.8(B) Surge Protection Requirements for Dwelling Units and Sleeping Quarters Working Space, Equipment Door Swing, and Egress Around Electrical Equipment This electrical code training episode is designed to help listeners better understand how the National Electrical Code applies in the field and why small wording changes can create major inspection, design, and installation issues. Whether you are studying for an electrical exam, preparing for NEC continuing education, performing electrical inspections, reviewing plans, installing service equipment, working on commercial electrical systems, or trying to understand the latest 2026 NEC changes, this episode provides clear, practical Code insight.If you work with the 2023 NEC, are preparing for the 2026 NEC, or want to strengthen your understanding of electrical code rules for grounding, bonding, GFCI protection, surge protection, service equipment, transformer secondary conductors, limited-energy systems, and electrical working space, this episode gives you practical NEC guidance you can use immediately in the field. Become a supporter of this podcast: https://www.spreaker.com/podcast/electrify-electrician-podcast--4131858/support.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

Speaker 1Welcome to the Master of the NEZ podcast, the ultimate destination for anyone passionate about the electrical trade. Whether you're a season electrician and eager apprentice, or just someone who wants to dive deep into the world of electrical work, You've come to the right place.

Speaker 2Join your host, Paul.

Speaker 1Abernavi, a true authority in the industry with over thirty eight years of trade experience, as he electrifies your mind within depth discussions, expertips, and valuable endsights that will keep you ahead of the curve. Each episode, Paul will illuminate the complexities of the trade, decode the National Electrical Code, and share the latest industry trends, all while empowering you to take your electrical career to the next level. So gar up, plug in, and get ready to supercharge your knowledge because with the Master of the NZ podcast, the

Speaker 1power is in your hands.

Speaker 2Now get ready. Here is your host, Paul Abernavis. What up, everybody?

Speaker 3Welcome to another episode of Master the NEC the podcast where I talk about the National Electrical Code and all things electrically related. People submit questions about all types of things. If you're the first time listener to the podcast, we have over a thousand plus episodes of all different type of topics for the electrical industry, whether it's bidding, estimating, hiring, firing, gorilla marketing, growing your business. Not just the National Electrical Code, but we do do a lot with the NEC and

Speaker 3talking about the changes and all that other good stuff.

Speaker 2All of it.

Speaker 3All you gotta do is go to your whatever search engine you want, It really doesn't matter. You just go to Google being whatever it is, and you type in their master the NEC podcast and you're gonna see that we're on Spotify, Spreaker, Deezer, iHeartRadio, Apple Podcasts, Google podcasts, and but all those other wannabes out there have not been doing in podcasts nearly as long as we have, so they can dabble in it a little bit, you know, the Jackerson's of the world, but at the end of the day, they don't even come close. So check it

Speaker 3out and you can hear a bunch of different topics that we talk about on the podcast.

Speaker 2Also, it is July of twenty twenty six.

Speaker 3So as you most of you probably know by now, I am an NEC consultant for E C and M Magazine. I do write articles for them and videos and podcasts, and I'm there one of their code experts, and so look for that in July, in their July episode, I guess towards the end of July or somewhere in there, you will you'll see an episode there where we're talking about the Inspector Intel and it's a series and I'm starting for them. Wanted to give them something a little

Speaker 3a little different, so we'll be exploring the relationship between inspectors and electricians and all that kind of good stuff. So that's gonna be a good series, especially if you've ever had a run in with an inspector or, if you're an inspector and you've had that pesky electrician, there's there's a way that we all can meet in the middle. So make sure you check that out. It'll be on E C and M Magazine, and I'm sure it'll be on their digital format as well, So make sure you subscribe to that. It's a free to get your subscription for E C and M Magazine, Great Magazine, Great Publication.

Speaker 3Mike Holt's been writing for them for well over close to I guess, and I shouldn't say well over forty years, and so now I'm gonna be writing for them, and so again I'm excited about the opportunity and we'll see where it goes. If I do more for them in the future, we'll see. But anyway, that's what we got going on now.

Speaker 2We're gonna be doing. This is not a part two episode today.

Speaker 3I did recently do an episode where I answered about I guess ten questions that people submit and kind of gave some answers to that. We're gonna do that again today. We're gonna answer some questions that I get submitted all the time. And it's been a while since I've really done a lot of podcasting, and it's my first love, way more than I do videos, because, to be honest with you, I know, if you're like me, I'm always on the go. So whether I'm in the car or i'm you know, wherever I'm at, it's easier for me

Speaker 3to listen to a podcast than it is to sit down and watch a video. And the interesting thing about me with podcasting is I always make it a challenge, because the challenge is really for me to try to paint a mental picture. And that's how I create these little challenges for me. When I do podcasting. It's not always that easy, but that's what I try to do. I try to paint this mental picture, all right.

Speaker 2So we're gonna do that today.

Speaker 3We're gonna we're gonna pick up on some questions that get submitted. Jeff has compiled these for me, and I'm just answering them. As you folks know, I don't I don't cut, I don't edit, I don't I don't do any of that stuff. I give you straight from the gut and talk about the NEC and I try to break it down so it's not overly code laden.

Speaker 2To the word.

Speaker 3You know, you can't follow along unless you have your codebook laying right out in front of you. But but you know, I might throw some references here or there. But remember, at all times when you're listening to this, you can always pause and go get your codebook, open it up, read it and uh and you know, back and forth in and out as you listen. It's a great way to learn the code, great way to enjoy the conversation. And at all times, if you have any questions about anything that we talk about, and you want to you want to ask additional questions, and remember that

Speaker 3you can go to our website fast tracks System that's t R a X by the way, not t R A c K. It's t R a X so it's fast, just like it sounds tracks t R a X System that's Y S T E M dot com. If you go there, you look under the info tab, you'll see where it says let's ask Paul and it's a very simple format for you to fill in the blanks, post your question, be as detailed as possible, and ask your question and if I will potentially answer it in a

Speaker 3podcast or an email directly back to you, but I will make sure that I try to get your answers and if I don't pester me, because I do get a lot of requests and a lot of them don't make it to a podcast.

Speaker 2I just answer the question or whatnot.

Speaker 3But again I can't say I'm perfect that some of them don't fall through the cracks, but it's not intentionally. I try to answer everything I can. I've been doing that for decades now, trying to answer people's questions.

Speaker 2So again that's a.

Speaker 3Way you can reach out, definitely through the website fastracksystem dot com. Also I should mention that we also have a message for them that you can go over to and post questions.

Speaker 2It's free.

Speaker 3All you gotta do is register over on any c c chat dot com, so just like it sounds any c chat and you can go over to it and join, and we have some free lessons. We have a free lesson over there about opacity, but also you can post your images, job sites, anything you want to post on there. We'd love to have you over on anyc chat dot com. All right, first question we have. Hey, Paul, I love your podcast. I do have a question for you. Can

Speaker 3you use the next standard overcurrent device sized rule for transformer secondary conductors the same way you might for general brand circuit or feeder conductors. Thanks again for all you do. Ignore the haters and keep posting those podcasts, all right, so appreciate it.

Speaker 2Thanks for joining.

Speaker 3And yeah I don't I act like the haters bother me, but I really could care less about them. My life's going to revolve around it anyway, and nobody will ever see their comments anyway, so eventually they'll get tired of it.

Speaker 2But that's okay. So the quick answer to.

Speaker 3That is that this is this is where a lot of installations get into trouble because it is very clear, since you're asking about the secondary conductors from a transformer, okay, is that the next size up rule in two forty dot four B does not apply.

Speaker 2That's a general rule.

Speaker 3Okay. If it doesn't correspond, you go to the next standard size those type of things. That does not apply to the secondary conductors for transformers. Okay, So the general rule next size up and two forty do four B is not a blanket permission slip, especially not for transformer secondary conductors. In fact, right into forty dot twenty one CE, it tells us that you cannot use to forty dot four B the next size up rule.

Speaker 2What does that mean?

Speaker 3Well, that means you must follow the actual transformer secondary conductor's rules being used, such as the ten foot rule, the twenty five foot rule, or one of the other specific provisions that are there in two forty dot twenty one C. Those rules include limitations on conductor length. They've got, limitation on conductor's opacity, physical protection, how they're outed, whether or not they're in a raceway or not, and then the course the location of where the overcurrent protective device is.

Speaker 3Now another thing that I want people to not get confused about. Is that four point fifty dot three B deals with the transformers over current protection. Okay, so since we're talking secondary conductors, four fifty four B is talking about protecting the transformer. Okay. So basically there's allowances for how long those conductors can be from the transformer secondary to the overcurrent protective device that they term it in

Speaker 3terminate into. So there's a LinkedIn and that's where we get the ten foot rule, the twenty five foot rule, the outside unlimited rule. But there's specific rules and so an example of that would be where you couldn't use an excise up. Well, let's say we had a five hundred KC meal copper that's three hundred and eighty amps and it was terminating on to a four hundred ample overcurrent protected device. So that would be a problem because if we've determined based on a calculation, that we're going to have a four hundred amp device that's protecting the panel board. So the panel board has its own rules

Speaker 3and four to eight dot thirty six, right, So if that's four hundred amps, then these secondary conductors will only be good for three hundred and eighty amps. They would not be able to go to the next size up rule and terminate on a four hundred amp over current device anywhere else that would be okay, typically because as long as the calculated low doesn't exceed three eighty, if the breaker doesn't correspond to protect it at three eighty, you go to the next standard size four hundred. That does not come into play when it comes to transformer secondary conductors. Okay, so you cannot do that. So I

Speaker 3just want to make that clear that that four point fifty dot three B deals with the transformers over current protection. Okay, it's not the same thing as automatically protecting the transformer secondary conductors in themselves. You're still going to five have to follow the rules and two one C for those secondary conductors. There's no getting around it. So the next size up rule does not come into play now. The twenty twenty six AC also adds clarity by using a

Speaker 3defined term for transformer secondary conductors, helping reduce confusion about where feeder rules begin and where the transformer secondary conductor rules apply. Okay, So I think as far as language wise, it's still the same as it always has been. You knew you couldn't use the next size up rule for the secondary conductors on a transformer, and so if you're terminating into a four hundred and amble over current device and a panel on the secondary of a transformer, then those conductors have to have an opacity of at least

Speaker 3four hundred amps period because we can't use the next size up rule where we could for feeders and other applications we can't hear. So I think that's a very important part to remember. Transform protection, secondary conductor protection, panel protection. Right that we talked about the overcurrent device in a panel four to eight dot thirty six, they are not the same type of conversion. So do not use four to fifty dot three B and try to ignore the rules in two forty dot twenty one C. That's not

Speaker 3how it works. You can protect the transformer, but it may not necessarily protect the conductors, and so when we're designing a system like that, we have to take all of these things into consideration. So yeah, just don't think that the four to fifty dot three B, for example, overrules anything else in the code like the conductors. And again in two forty dot twenty one C for protection, don't assume that because that's not how it works, okay,

Speaker 3And that's the thing about the National Electal Code is is we have to understand that you'll at one moment you'll be in this part of the code, and the next minute like two right for the secondary conductors, and then in the protection of those conductors, and then the next minute you'll be in four point fifty, which is purely about transformers and what we're talking about overcurve protection. Here, we're only talking about protecting the transformer. So you know, that's that's where it can get real confusing for people.

Speaker 3But sometimes if you can really kind of put it in your mind and treat all these things separate, just don't forget there are other areas of the code that you have to venture into. Right, So hopefully that makes sense. But that's that's a big one people run into. They you know, the next size up rule does not apply to the secondary conductors on a transformer. Let's see here. Great question though, Next one says Paul, what changed in the twenty two What did they say? Oh, what changed in the twenty twenty six? A NEC for service disconnects

Speaker 3and emergency disconnects at one and two family dwellings. Okay, Well, you probably most all of you remember the advent of the requirements in two thive under the twenty twenty three code right, which required the emergency disconnect for those one and two family dwellings. That was added. We've been toying with that for a couple of cycles. He got added in twenty twenty three, so you know that's uh. People have gotten used to that. At least if you're in

Speaker 3the twenty twenty three you got used to that. You're gonna put emergency disconnect outside. That emergency disconnect may also be a service disconnect very well, could be.

Speaker 2It doesn't have to be. You could have.

Speaker 3A switched outside that would be a service rated but used instead of that be used as an emergency disconnect and still pass through and hit a service disconnect. You could still do that, or you could have something outside that's not only the emergency disconnect but also the service disconnect, and all this was given to us in three options. Of course, you can have a meter disconnect which could serve as emergency disconnect. And remember we're not about about a cutout switch on a disconnect. We're talking about a

Speaker 3true disconnect, not that little lever that that that goes to under the meter. No, we're not talking about that. That is not a disconnect, right, so don't confuse it. But you get three options under two thirty done eighty five in the twenty twenty three edition of the National Electrical Code. Now in the twenty twenty six edition, that separate emergency disconnect section was actually deleted and the concept was reincorporated into a revision to two thirty dots seventy.

Speaker 2So it didn't go away.

Speaker 3Okay, didn't go away, it just got reincorporated into two thirty dots seventy. So the service disconnect for a one to two family dwelling is now required to be readily accessible outdoor location either on.

Speaker 2The dwelling unit or within sight of the dwelling unit.

Speaker 3Significant changes when it comes to that, right, So the service disconnect mean again readily accessible. That didn't change, but the outdoor location either on the dwelling or within sight of the dwelling That would be an example where would be maybe offset away from the dwelling in on a pole and panel or board or whatnot. Then that type of thing, So still doable to do that. Obviously, it would be within sight, within sights, within fifty feet and

Speaker 3site right, Now, the twenty twenty six also required that the service disconnect to be marked service disconnect. That was again service distincts were required to be marked service disconnect. But this is very clear and for one of two family dwellings, the enclosure of the service disconnect is also required to be marked emergency disconnect using the marking format that is given into the in the neec Okay, So the twenty twenty six version did not eliminate the emergency

Speaker 3disconnect concept. They just folded that concept into the service disconnect rules for one and two family dwellings. That's all it did, right, So instead of being purely something that you would see in two thirty dot eighty five, now you're seeing that rolled into two thirty dots seventy A to thirty dout seventy B and all that kind of stuff. So it's not gone. People say, where did it go? Did it disappeared? No, you still have the emergency disconnect requirements and all that, but it's just been rolled into two thirty dots seventy So not gone, just kind of

Speaker 3re rolled into another section in the code.

Speaker 2That's all still there.

Speaker 3Let's see, the next question we have is in the Paul in the twenty twenty six AEC. Can we still say that chapter eight communication systems are mostly independent from chapters one through seven?

Speaker 2Well, not like they used to be, Okay.

Speaker 3Historically chapter eight was a special status if you will. It was generally not subject to chapters one through seven rules unless the course eight specifically referenced those requirements, and the course if it did, then they obviously would be applicable because they made reference to them, right. But the twenty twenty six code changed that structure. So under section ninety oint three, and there's a specific figure there, this was all revised and now chapter eight is no longer treated as a standalone chapter in the same way. So

Speaker 3it basically chapter eight, which is communications systems, and then it's course outside and Entering Buildings. It is incorporated now into a general requirement. It is not a standalone anymore.

Speaker 2Okay.

Speaker 3So this is impactful because it makes it really clear and the code change these things. When it used to be chapters one through four applied broadly, and then five, six and seven supplemented and modified by now adding eight in there, it now makes it it's not standalone anymore. It's literally incorporated into the requirements of the code. So the phrase it's just low voltage, what people used to say, is become even a weaker statement now because the NEC

Speaker 3the twenty twenty six many limited energy and communication installations inside buildings are more clearly tied to the broader scope.

Speaker 2Of the NEC now.

Speaker 3So by just pulling in chapter eight now brings in that communication systems are very much mandatory by the NEC and no longer treated as a standalone feature.

Speaker 2If that makes sense, let's see here. Next question, Paul.

Speaker 3Does the NEC use accessible, readily accessible, and within sight to mean the same thing. No, these are separate concepts, okay, and I guess the easiest way for me to do this would be to paraphrase them out or try to explain each one of them separately.

Speaker 2Accessible. So, accessible in.

Speaker 3General means capable of being reached or exposed without damaging the building structure or finish. So if I have a box that has a cover on it, I take it off, the wiring inside of it's accessible. If I have a lumina air and I take the luminair off, the conductors in there aren't required to be readily accessible, They're just required to be accessible. Are they accessible? Absolutely. I didn't remove any of the building structure or finished I just removed the luminair to get to it. So that's inaccessible. Now, Readily accessible is a higher standard. It means that the

Speaker 3equipment can be reached quickly without having to climb over obstacles, climb under obstacles, remove stored materials, use portable ladders, or take any type of similar action to get to something. For example, in the code, you'll see that a GFCI device is required.

Speaker 2To be accessible.

Speaker 3Okay, and so we'll see that and we'll say okay, So in fact, if you go to two ten dot eight, that did not you know, that did not change in the code.

Speaker 2Just so you know. You go to two ten dot eight and you read it and what it says.

Speaker 3It says in fact, it has to be readily accessible. That is a higher level than just accessible, because if it was just accessible, then I could get to it with a ladder, I could get to it. Readily accessible means that you know what.

Speaker 2To get to it.

Speaker 3I can't resort to using something like a ladder climbing in climbing under having to move some obstruction. That's a bigger threshold to have to meet. So example, we always use this one in a garage. If the receptacles in a garage are required to be gfc I protected, then you can either put the receptacle down low, not more than five feet high, which means it's going to be dedicated to the garage. If I put the GFCI in there, and at the end of that's you know, that run of receptacles, it ends up with a receptacle in the ceiling.

Speaker 3For a garage door opener, for example, that circuit has to be GFCI protected. All of that is GFCI protected. But you wouldn't put the device in the ceiling, you know where you push it and reset it and trip it. No, you wouldn't do that because it require a ladder to get to it, so it's not readily accessible. If you want to put it down at the five feet mark on one of those receptacles that are going maybe going around the garage, that's fine. If you want to put a braker in a panel, that's fine. Protects the whole circuit.

Speaker 3It's going to be a gfc I protected and thus that receptacle at the end of that loop is going to be GFCI protected. But the GFCI device itself has to be readily accessible, and that means I'm not going to have to pull up a portable ladder or move any store material, climb over or under any obstacle to get to it. Now, I don't I need it needs to be readily accessible, don't need to go grab something else to be able to get to it.

Speaker 2You know what I'm saying.

Speaker 3Ah, So then the next one is within sight. It's a that's a totally different, separate concept. Traditionally it meant visible and not more than fifty feet away. Now, in the twenty twenty six within site definition was removed from article one hundred, and the concept is now addressed in one ten dot twenty nine, and that language expanded to cover equipment, buildings, and structures. So the takeaway that you want to kind of take away from this where it's accessible,

Speaker 3readily accessible, and the course within sight it says, you know, the key is don't try to mix these terms together. A disconnect may be accessible but not readily accessible, whereas equipment may be readily accessible, but then again it's not within sight. So the NEC uses each phrase independently for whatever the code tells you. The criteria needs to be. If it says that it has to be readily accessible, then it's got to be readily accessible, and that means

Speaker 3it's got to be what reachable quickly without having to climb over or under or remove store material, use portable ladders to get to it, or something to that effect. Then it's not readily accessible. Okay, within sight. If the code says, for example, a disconnect to a motor has to be within sight, then it needs to be visually within sight of the motor or the controller, and it also needs to be within fifty feet. Pretty simple, right, but that wouldn't come into the equation of readily accessible

Speaker 3versus accessible. This is each one of them get treated differently, and the code will tell you when something needs to be accessible, when it needs to be readily accessible, or when something needs to be within sight, those type of things, the code will will dictate that to you. Some of the areas to be aware of in the twenty twenty six is obviously one ten twenty six, one ten twenty nine, things like that. So it's important just to remember this the scope outline of it, that these are distinctively different things, Okay,

Speaker 3distinctively different things.

Speaker 2Okay, next question.

Speaker 3That somebody has for me, It says, uh, Hey, Paul love the podcast, I got a question for you that I've always wanted to ask. In the twenty twenty six NEC, did the dwelling unit GFCI rule for garages and accessory buildings change? So?

Speaker 2Yes.

Speaker 3In the twenty twenty six NEC revised the organization of two ten dot eight A. So in the twenty twenty three dwelling unit, garages and certain accessory buildings were combined in the same list item. In the twenty twenty six NEC, garages are separated into their own list item and accessory buildings are addressed separately. Now the change helps clarify that GFCIP protection applies to receptacles in that area of accessory buildings that are not intended as habitable rooms and are

Speaker 3limited to storage work and similar use. Now the twenty twenty six revision also modifies the exception for a factory installed receptacle inside of an exhaust fan assembly.

Speaker 2Okay, so the.

Speaker 3Key takeaways here is a finished habitable room in an accessory building is not the same as a garage, storage area, workshop, or similar non habitable area. So the twenty twenty six ANYC language makes that distinction very clear. So garages, yes, slat out, still in there to ten nine eight A two still in there. The key here is item three, which now separates it out and.

Speaker 2Just talks about the accessory buildings.

Speaker 3It says areas of accessory buildings not intended okay, so they're like unfinished, they're not intended as habitable rooms and limited to storage work and similar usage. So that's the key. If it's a accessory building and it's not going to be used as a habitable room and it's only going to use for storage work and similar type usage, then GFCI.

Speaker 2Would be protected, would be required.

Speaker 3If it is an accessory building that is intended to be used as a habitable room, then this wouldn't You wouldn't require the GFCI protection.

Speaker 2Makes sense.

Speaker 3So a finished habitable room and an accessory building is not the same as a garage. It's not the same as a storage area, it's not the same.

Speaker 2As a workshop.

Speaker 3People have been asking for this for a long time because there's a lot of people accessory buildings. Because of the language, they were forcing this to require a GFCI protection, and it really was a finished off habitable room, and of course you're gonna have to go look at the building code and understanding habitable rooms and a definition of habitable rooms and all that that kind of good stuff as well, so be aware of all that. But again that is that is the change when it comes to that, and it just broke out the from garage and similar

Speaker 3areas of accessory buildings to kind of breaking them out separately. But you know, in our case we can just go to for our needs here when it comes to the NEC, we can escip the building code in argument with the building folks and just go right to the definition's article one hundred and see if we don't have habitable room, and we do. It says a room in a building for living, sleeping, eating, or cooking, but excluding bathrooms, toilet rooms, closets, hallways,

Speaker 3storage or utility spaces, and similar areas.

Speaker 2So if the accessory.

Speaker 3Building is being used for living, sleeping, eating, cooking, okay, then you know, there you go, it's a room. And if it's a habitable room, then it wouldn't require the GFCI protection anything other than that GFCI protection.

Speaker 2Okay, if it makes.

Speaker 3Sense, Okay, okay, next question, let's see here. Oh, by the way, I will remind you if you want to learn more about thermography and electrician you want to add thermal imaging to your scope of work. If you really want to understand thermal imaging and be able to add it, it's a great thing.

Speaker 2If you really know how.

Speaker 3To use thermal a thermography camera, you can really find a lot of things. But we don't want you to be crying wolf. So we have two great courses on that. We have the CTE Certified Thermal Electrician program that's available through Thermal electrician dot com, but you can also all of these are available on our website as well as for the courses. And so there's a basic thermography course which I think everybody should take. It covers way more than what electricians would need to know, but that's a basic course. And then of course we have the certification program,

Speaker 3which you can get even deeper into if you want to understand it.

Speaker 2We designed it so.

Speaker 3That it's not overly laden with pictures from thermal cameras and all that, because we really want you to use your thermal imaging camera and we really want you to look at the numbers, because what I've found with people is it's so easy to get misled by numbers rather than the actual pictures, rather than the actual numbers itself or the values. So we focus on the values. You can use your camera, but we are really focusing on the number of values to teach you the difference so that you're not going to cry wolf. If you're interested

Speaker 3in that, go check it out on our website Thermal Electrician dot com.

Speaker 2It's a great program.

Speaker 3You'll learn a lot about thermography, and I feel a lot of electricians need to understand it and make sure you don't cry wolf if you go messing with one that you truly understand how to work it. That's a key thing, all right. Next question, excuse me, says Paul. What are some of the big GFCI issues electricians miss in commercial or other than dwelling unit installations.

Speaker 2Let's see.

Speaker 3Well, I guess, I guess, if I have to think about it, I think the biggest mistake is thinking that GFCI is only a for a dwelling unit issue, right, So I guess that's the biggest thing that I would have to guard against for people to say.

Speaker 2Look.

Speaker 3In twenty twenty three, NEC you had two ten point eight B which expanded GFCI requirements to other than dwellings.

Speaker 2New or revised.

Speaker 3Locations included areas with sinks and permanent provisions for food preparation, beverage preparation, cooking, buffet serving areas, and receptacles near aquariums, bait wells and similar aquatic vessels. So all of this was incorporated into the twenty twenty three edition of the NEC. These are uniquely different. They have nothing to do all with dwelling applications. So this is like other than dwellings. So again I think making people aware of that, and

Speaker 3they're used to GFCI, and they go into a commercial space and they forget that, and guess what, You've got rules for GFCI applications.

Speaker 2Here as well. And sometimes people forget that.

Speaker 3They're so in tuned to think in GFCI is just a dwelling unit thing, it's not another I guess. Another practical issue is the sink rule. It is not just the receptacle location that matters. The rule can also apply where cord and plug, kinnetic, fixed or stationary appliance itself is within six feet of the top inside edge of the bowl or the sink. So that is another big one where people think it's just a stationary receptacle. And again if you look at the National Electrical Code, it's

Speaker 3different now. Right. For example, in a commercial work, you don't stop at is this a kitchen, You look for sinks, You look for food and beverage preparation areas, You look for buffet serving areas. Now you look at rooftops, garages, service bays, launder areas, commercial launder areas, locker rooms, and similar areas that are listed in two ten point eight B. So I guess for me, the key takeaway is let's not think that GFCI protection and all those requirements are

Speaker 3locked specifically just into dwelling applications when there is a vast number of other areas that GFCI protections required. So, I mean that's just a reminder to people. I'm sure you're already aware of it. I just want to make sure you don't lose sight of it because you could walk into somewhere that you're not familiar with whether or not GFCI required. Again, last cycle, buffet was added. Receptacles that are on a buffet line, Well, you might not have done that before. And if you're not thinking about it, you get in there, and now you've got a requirement

Speaker 3for those to be GFCI protected, and that was in the twenty twenty three and it didn't change for the twenty twenty six. So I get that's the biggest area that I would say, just be aware that that there's more than just a dwelling unit when it comes to GSCs. Okay, I don't know if that answers the question, but that is one area that I would tell you to be aware of. Let's see here. Next question is where does the NEC require surge protection and what changed in the twenty twenty six NEC.

Speaker 2Well, in the twenty twenty three.

Speaker 3Search protection devices are required for service supplying dwelling units. Okay, that was in two thirty sixty seven, and then of course we had feeder level search protection in two fifteen dot eight for certain types of occupancy, so we got that, I guess in the twenty twenty six a NEC it's expanded that search protection concept to include areas designed exclusively as sleeping quarters in fire stations, police stations, ambulance stations,

Speaker 3rescue stations, ranger stations, and something similar. There's similar locations that would be very similar. The expansion that you see with those locations appeared in both the feeder and the service search protection requirements, so it's just expanded. Use just be aware that it's expanding out, and the search protection is now growing into again anything that would be running to feeder panels or whatnot, that would be serving fire station,

Speaker 3police station, ambulance and so forth, no type of thing.

Speaker 2So this is important because.

Speaker 3Modern sleeping areas often contain life safety electronics, smoke alarms, afcis, GFCIs, communication equipment, and the other sensitive electronic equipment, and the whole gear or the whole premise behind these search protection is to try to protect those sensitive electronic equipment. And they may be in those specific areas, and obviously in those areas you're to have more chances of having things like smoke alarms, uh and things like that, and and

Speaker 3so the protection is there and they want to make sure that you keep that protection when it comes to search protection that type of thing. So search protection is no longer just a dwelling unit conversation. It is, you know, it has expanded over the last couple of years, and then the twenty twenty six expands to focus into sleeping areas for emergency response and similar facilities. So if you've got a panel and a panels located in these areas, then you're going to have to meet these rules and

Speaker 3two fifteen eighteen A and two thirty sixty seven A. Now it's just expanded locations. That makes sense. Let's see here, let's see I got another question here. I try to find as many as a kid. Okay, here's here's we'll do this one and this would be the last one for this episode.

Speaker 2I don't want to get a little long.

Speaker 3My last episode was pretty long, so I don't know if people actually listened to a whole hour. But this one says, hey, Paul, when electrical equipment doors are open, can they block the required working space or egress path? No, that's an easy one. So working space and egress are not measured only where the equipment doors are closed. They're measured when they're open. Now, in the twenty twenty three NEC, it really already clarified that open equipment doors cannot impede

Speaker 3access to and egress from the working space. We already established that. Twenty twenty three made it very clear there was a discussion in ECM magazine Electrical Contractor Magazine, and they noted that the access or egress if impeded when it's open door equipment reduces the path below twenty four inches and six and a half feet I created a hazard. So the twenty twenty six NEC continues refining this issue.

Speaker 3So industry summary is explained that equipment doors swung open must be considered and that the twenty four inch egress path must remain available with equipment doors open to ninety degrees.

Speaker 2So even if the equipment then the doors.

Speaker 3Are opened to ninety degrees, you still must maintain the twenty four inch egress path around these doors.

Speaker 2Now.

Speaker 3They also revised one to ten dot twenty six two in the twenty twenty six for large equipment by adding a feeder disconnect means installed under two twenty five dot thirty three A to the large equipment egress rule, along with service disconnecting means under to thirty dot seventy one B.

Speaker 2So what's the takeaway for you and me?

Speaker 3Electrical room layouts is not just about fitting the gear into the room, and a lot of times these rooms are getting smaller and smaller because the engineers are trying to stuff as much as they can in there, because those are dead spaces that don't make the owner's money. So we want to cram as much as we can ten pounds of crap in a five pound bag, so to speak. But you must account for this working space. When these doors are fully open, you must maintain that escape path, that egress path. Okay, So whether it's large equipment,

Speaker 3egress rules are triggered or not, you still have these requirements that have to be met. And that's kind of clarification came in the twenty twenty six edition of the NEC. So if you want to go look at it, you know you're going to be looking in the twenty twenty six That is, you're gonna be looking at one ten dot twenty six A, one twenty six C, two two twenty five, thirty three A, and of course two thirty dot seventy one B.

Speaker 2All of this is pretty much going.

Speaker 3To show you that we have to maintain this egress and access uh and has to be maintained.

Speaker 2Even when those doors are wide open.

Speaker 3Even when they're open, then we have to maintain this clearance, right and it's for safety electricians moving in and out anybody could get trapped in there during an incident. Okay, So again, all these rules. A lot of people complain about various rules, and I think at the end of the day, a lot of these rules are to protect you, the electrician, especially if you have to come back and service something. Right, So working clearance is extremely important. If somebody starts storing stuff and you're asked to come back and do something and all this stuff is in the way,

Speaker 3you should refuse it until they clean it out. Give you the path that you need, give you the clearance you need to work safely. Last thing we want is they're have an arc flash incident and you get trapped in something and you get injured. We all have families. We all want to get back to our families every day. We're just out here to make a living, okay, you know, we all still have a life, and so it's important.

Speaker 2So some of the things that we require.

Speaker 3In the NEEC you may not like, you may not agree with, but this is a minimum safety standard. It's not a perfect but it's about as minimal as we can get and still be effective. And can you go above the minimums absolutely? Can you go below the minimums absolutely? Not, and I think that's critically important for everybody to understand. All Right, all right, folks, that's all we're gonna talk about in this episode. Hopefully you got something I know. I talked about a lot of these at a thirty thousand foot level. If you have any specific questions on

Speaker 3any of this, remember this is a two way street.

Speaker 2You can always reach out to me.

Speaker 3Just go to fasttracksystem dot com. Go to the info tab. You'll see a drop down and you'll see the let's Ask Paul button. Click on that, and please, by all means, feel free to send us a question. Reference this episode, reference the question or put your question there based on what we talked about, and I will give you the best answer I can. All right, all right, until next time, folks, Stay safe, God blessed. We'll catch you on another episode of Master the NEC podcast.

Speaker 2Check it out.

Speaker 1Thanks for tuning into another electrifying episode of the Master of the ANEC podcast. We hope you're feeling more powered up and ready to tackle the electrical world with the knowledge and confidence you need to succeed. Remember, in the electrical trade, knowledge is power, and we're here to make sure you stay flogged into the latest insights, tips.

Speaker 2And code updates.

Speaker 1If you enjoy today's episode, don't forget to subscribe, leave us a review, and share the podcast with your fellow electricians and industry pros. Until next time, keep your tools sharp, your circuits clear, and you're my focused because here at the Master of the ANEC Podcast, we're all about sparking your success. Stay safe, stay smart, and keep mastering the trade. From all of us here at Electrical Code Academy, thank you for all your support work, and we will see

Speaker 1you on the next amazing Master then EC Podcast episode

Speaker 3Mm hm

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. NiteNerds™ — The Future of Permanent Outdoor & Landscape Lighting Is Here!

    Nov 12, 202631 minAudio

    NiteNerds™ - The Future of Permanent Outdoor & Landscape Lighting Is Here! What if your home could look absolutely stunning every night of the year - with the touch of a button? Welcome to the world of NiteNerds™, where...

    Credit the people on this episode

  2. MASTER THE NEC PODCAST | E81 | Electrical Code Knowledge and 2026 NEC Updates PT 3

    Oct 18, 202655 minAudio

    ⚡ MASTER THE NEC PODCAST 🎙️ Hosted by Paul Abernathy Master Electrician | National Electrical Code Expert | Electrical Educator ⏱️ Episode Length: 55 Minutes ⚡ ABOUT THIS EPISODEWelcome to Episode 81 of Master The NEC,...

    Credit the people on this episode

  3. MASTER THE NEC PODCAST | E80 | Electrical Code Knowledge and 2026 NEC Updates PT 2

    Oct 18, 20261 hr 23 minAudio

    ⚡ MASTER THE NEC PODCAST 🎙️ Hosted by Paul Abernathy Master Electrician | NEC Code Expert | Electrical Educator⏱️ Episode Length: 1 Hour, 23 Minutes ⚡ ABOUT THIS EPISODEWelcome to Episode 80 of Master The NEC, where...

    Credit the people on this episode

  4. MASTER THE NEC PODCAST | E79 | Electrical Code Knowledge and 2026 NEC Updates PT 1

    Oct 18, 20261 hr 4 minAudio

    ⚡ MASTER THE NEC PODCAST 🎙️ Hosted by Paul Abernathy Master Electrician | NEC Code Expert | Electrical Educator ⚡ ABOUT THIS EPISODEWelcome to another episode of Master The NEC, the podcast dedicated to helping...