Adam: Hey everybody, welcome back to episode 69. This is Build Connected with your host, Adam.
Pace: And your other host, Pace.
Adam: Hi Pace.
Pace: Hi.
Adam: well I'm I'm sh I'm I'm straight off the job site to jump into this podcast. we're in the dirt. We're we're digging. We're moving concrete, as you know.
Pace: Yeah, you're in the dirt. You've chosen to go bags on, so you're deep in the dirt and you're an old guy.
Adam: Yeah, I'm the old guy on on the job site filling in for one of our one of our our our lead guys is on vacation for the month, so you know I'm stepping into his shoes for a little bit. And yeah, you know it hurts a little bit, but it feels good at the same time. I'm like a I'm like a puddle right now. Digging in the dirt, running the jackhammer, cutting concrete. Good stuff. How you doing? You look all comfy, cozy in your home office.
Pace: I am not in the dirt.
Adam: Let's let's jump into things, shall we? What's the topic today, Pace?
Pace: I wanna talk about Tyvek as a product right right off the bat and like I think I think this episode is gonna be t particularly heated. I have a feeling.
Adam: Ooh, he's an angry elf today, folks.
Pace: I am an angry elf. So here we go. Let me set the scene. My neighborhood has three construction projects, three active remodels. All of them involve some degree of siding replacement. And all three of them, all three contractors are using Tyvek. I know one of the projects pretty intimately. We bid actually on a portion of it and we didn't get it, right? And I've been watching. I've I've been watching the contractor work. And you know, they chased, they chased some rot and they removed some siding, and you can see that either a window or a vent cover allowed some water to come in and it got trapped. You know, there's OSB sheathing, there's Tyvek, and then there's a no drainage plane, and then there's siding. Right, and got it got stuck in between there, and it slowly over the years it led to some rot in that sheathing. And so their solution was to peel back that area, patch back in some OSB, put Tyvek back on with no drainage plane, and put the siding back on. How is that allowed in this day and age? Now, to my to my knowledge, there's no permit on this job, but even if there was a permit. That would be okay. That would that would be okay to construct that way. And I think that that's a problem.
Adam: Maybe these maybe these are some old timers over there doing that work. You know, there was a time period where Tyvek was the standard, right? I mean, with the new technology and all the wonderful products we have today, like why would you ever use that product? I can't understand it for the life of me. who are these guys? Who are these hoople heads putting Tyvek in?
Pace: I know who they are. They're they he is an older guy. He's older than me. He's very popular in in town. He's a very
Adam: there you go. Okay.
Pace: reputable builder. But I just don't think that the product should be allowed. Like we have all of these requirements for you know air barriers on new builds. Like I it feels like remodels in this in this particular layer, if you will, there's no rules. Like w like Come on, we're talking about you can't pass an inspection without rodent-proof caulking on all of your plates. Like, how is that a bigger concern than not having a drainage plane? Like, this is a great example of California dropping the ball, in my opinion. And I I am actually
Adam: But you can you
Pace: arguing for regulation in this case.
Adam: But y pace you can still have a drainage plan and use Tyvek. What's your gripe with the material itself, or maybe it's just the way it's installed, because you rarely see that installed properly. That's the problem.
Pace: Sure, sure. So you're right. You you can definitely have a drainage plane, but they do not have that in any of the examples that I'm referring to. It's not only that, it's just like one of the jobs I drive by and it hasn't been sitting. This is like an active job. It's only been a couple of weeks. I can see tears in the Tyvek. Like right, they've they've done their lap with with like the next the second course, if you will, of of Tyvek. They've stapled it. with what I would consider inferior staples. And there's tears. Like I can see sheathing from the street.
Adam: Well, your your problem is probably not r so much related to the the actual material. I mean, obviously the installation has been done incorrectly, right? No cap staples, tears in the paper. It's probably not taped. It's probably all crinkled up, right? I mean, the product is vapor permeable, right? It's a WRB. It's designed to keep water out and let vapor diffuse through it. Is that am I wrong?
Pace: Yeah, I mean I I think that is wrong. Like let me just look at it this way. Without a drainage plane and an improper non cap staple, right, what happens well certainly if you were doing an air barrier, this wouldn't be your your method, right? You wouldn't use this you wouldn't
Adam: Yeah. I mean I would never I would I wouldn't I'm I'm just asking the question. I would never use this product because there's far superior products out there that we prefer to use. But
Pace: Okay. Like it the way I think about it is water gets behind that that siding, right? And there's no drainage plane, right? Water's pinched. If you've got just like a a staple on a on a non-sealing product like Tyvek, right, water's gonna migrate through that that staple hole. Right? Like that's just an inferior product. If we are being so critical of all the products we can use here in California. Why is this one still allowed is I think is my point.
Adam: Understood. Yeah, I I it's a good question, Pace. it it seems to be on the bottom of the totem pole when we talk about all these WRBs that are out there. But you're right, it's still being used in a lot of places. I've seen it in a lot of places. You're seeing it in your neighborhood, I don't think people know how to install it correctly, but it's also at the bottom of the totem pole with all the WRBs that are out there. I don't know why you would make that selection to use that product over over something else. But
Pace: Yeah, because in this case, like like I said, three three different projects, all of them have a WUI compliant siding. So somebody's thinking about something. Like, why wouldn't you, and we're we're talking about an entire facade, right? Not the whole house. None of them are the whole house, but in each case, it's the entire one side of a house, right? Like you take the opportunity that you have to build to code, right? You don't miss the opportunity to build better. even though it's not the whole house. Right. This is something I learned early in my life on this old house. Right. It's the argument, the rest of the house is built this way. Why bother doing something fancier on this one side? It's because it's your opportunity. Like if you get the opportunity on the next wall, right, you you take the opportunity there. And eventually there's no regrets.
Adam: And well sorry, I you know I didn't mean to cut you off there, but yeah, I mean that's something that code abides by too, right? I mean, even though we might be remodeling a small section of a house, we are still required to follow protocol and certain code compliant methods, means and methods of installation, because They say, well, if you're gonna remodel other areas of the house later on, you need to kind of keep that uniformity. But you know, you gotta follow that procedure and and take advantage while you can, even though it's just, you know, even though the rest of the house isn't like that.
Pace: Yeah. Yeah, I I I hear ya. I'm gonna I'm gonna kind of spin off of this one I mentioned a referendum a few episodes ago, right? And I I was listening to a podcast last week and I it was an interview with Rahm Emanuel and he had a comment that just really struck me as better. It's it's a better idea than mine. or maybe his idea in combination with mine would would really get us somewhere. And his thought was if he was mayor again in Chicago, and the the question was regarding how do we build more affordable housing, right? How do we get out of the housing's too expensive problem, the homeless problem, the regulation problem? His answer was we take our code and we compare it with Dallas, Texas. Like Dallas, Texas, because they are a place that's building fast, right? They are ahead of their housing crisis. And so we we stack our code up against Dallas, Texas, and everything that's different, we need to justify it. Right? We have to give a reason, a solid reason why that code should be there when it's not in Dallas, Texas. And I love it. And it can't be you're building professionals or you're you're Planning professionals who are doing that assessment. It has to be a neutral party, right? I don't know how you get to that. I use the word jury duty, a representative collection of people that's that's doing this comparison. It can't be your planning department who's justifying it, right? Because you know they are adept in in that justification. I'm talking about an independent panel that's that's saying, yes. It is different and this is why we need it here in Chicago. I think there's an there's an answer inside of that somewhere.
Adam: Where do you start?
Pace: Where do you start? You start somewhere. How's that? Right? Ten thousand pages, pick a page.
Adam: Page pi page one. Page one. Start flipping through.
Pace: I got plenty of pages here in California that we can start with. So if I'm on that panel, I'm gonna put forward a few for sure.
Adam: Well look, Pace, you're talking about regulation. You want to compare this this code that we're dealing with on a the something interesting on a job topic here, how it relates to let's compare this code to a Texas code. Okay? Alright, so
Pace: Yeah. This is a great one.
Adam: so listen, we're you know, we're on a commercial project. we're building a restaurant and we are putting a new kitchen in. And there's gonna be a service window in this kitchen to pass food through. And code tells us that we have to keep this service window at a certain size. the clear opening can't be more than 240 square inches, I believe, So that leaves you with an eight inch tall by thirty six inch wide opening. I mean, how do you slide a plate of nachos through that? You know what I'm saying?
Pace: Yeah, I mean that configuration can be whatever you want, but but the idea is it can't be more than a maximum of two hundred and forty square inches. And it's it's because in this case we've got roll-up garage doors. So they're looking, even though the window is inside of the restaurant, they're considering the inside seating is outside because the doors can roll up. So the code is there for flies, but a good way to think about this is McDonald's, right? You pull up to any McDonald's in the country. They slide open a window, they take your money, they give your food. None of those windows comply with the code in California. And so the example that you gave, if you wanted a 30-inch wide window, you could only have that window be eight inches tall. And that is insanity. Right?
Adam: Is that is that not a code in Texas?
Pace: I doubt it. Do I do I
Adam: I
Pace: know do I know that? No, I don't know that. But I doubt it.
Adam: So wha how do you deal with all the flies?
Pace: Fly traps, fly strips, open and close the window.
Adam: What I mean I guess you get Mr get Mr Miyagi to sit there on a stool with some chopsticks, maybe?
Pace: I mean how does how has McDonald's dealt with it for the past hundred years? Eighty years, whatever.
Adam: Well, the the service windows are pretty small, aren't they?
Pace: They're certainly bigger than two hundred and forty square inches. You know, if I had to guess, I'm gonna say like a typical drive-thru window is somewhere in the four feet tall by sixteen inches wide in the open position. That's what I'm gonna guess, right? That is well outside of the code here, right?
Adam: Well, how do they get away with it in California?
Pace: Well, it's because it was built before the code went into effect. So yeah, that's my point. If you were to build a McDonald's right now, you couldn't have that drive-thru window. Do you think this is a good code?
Adam: Absolutely not. This is a horrible code. How's that helpful? I I don't I don't get it.
Pace: The code is there because somebody in an office said flies are carriers of disease. We need to limit the number of flies that are in a food production area. And so what's the best way to do that? Let's minimize the size of any opening to that area.
Adam: Well look, you the the codes are changing so often as we know, right? When we talk about this, every year there's tons of new codes. Like this is a code that we've just learned about. This wasn't around the last restaurant we did. And yeah, it is ridiculous. I mean if you talk to your your contractor buddies in Maine, I'm sure they would eat this up, wouldn't they?
Pace: Yeah, and I mean even more more troubling is what everyone's doing is they pass their final inspection and then they alter the situation so that they can serve food efficiently, right? This gets in the way of running an efficient operation. And so there's a dance that's being done, right? It's like let's pass our final inspection and then let's put it the way we want it to run a restaurant. That's what's happening on the ground.
Adam: Yeah, I mean the the the funny thing too is you know when you have the inspector out there and you have a conversation with the inspector, he nods his head and is like, Yeah, you're right, this is the this is a dumb code, but I gotta follow protocol.
Pace: so the thing that frustrates me is that's not the way to change. That's not the way to make things better. Going along with it because that's the way it is is not the answer to bettering a situation. Right? Calling it out and saying, hey, maybe we overreached here. You know, maybe this doesn't make sense. Let's pull that back. I think there's there's so many things that are easy to to identify as maybe a step too far. Let's d let's dial it back. The problem that happens with regulation is that doesn't happen. It just doesn't happen.
Adam: it's because you have all the all these people in the field, right, that are experiencing it firsthand, where and then you have this other batch of people that are in an office just thinking this makes sense outside of the real world, right? So you have these two groups of people that don't interact, right? And so you you have to have somebody that understands that, that can bring it to the forefront of the people behind the scenes. And
Pace: Right. And so th maybe I'm not being explicit enough. Where the problem is, is right, the people who are not in touch with the real world effects of these regulations are the ones who continue to stack regulation on top of that regulation. Right. And so the idea when I use the word neutral or independent party, committee, whatever, it's to break that cycle. Right. It's It's to stop the building and the planning departments from continuing to lair successively onto things that are inefficiencies and restrictions and things that are in the way of us building the housing that we want, right? That we that that communities are demanding. These are the things that are in the way of it.
Adam: Sounds like you should be running for mayor.
Pace: Yeah, we keep coming back to that. And
Adam: Yeah.
Pace: the follow up is I would be dead already. well, that was a lot about regulation. There was a lot of anger pent up in there for good, good reasons. I hope that in the coming years there's episodes where we talk about, man, isn't this a step in the right direction? I want to hear myself say that so bad. I want to say, wow, they changed that regulation. Somebody saw, you know, the negative effect that wasn't intended originally. They saw it and they said, why don't we change that? Or why don't we eliminate that? I cannot wait. I want that to happen.
Adam: It's comin', let's just see if it happens before you retire.
Pace: Yeah, time's running, time's running out. All right, well you need to get back in that hole. Get back on the jackhammer and back to work. Thank you everybody for joining us on another episode of Build Connected on Pace.
Adam: And I'm at
Pace: See ya.
Adam: Thank you.