Part 2: Choices and Tradeoffs in Non-Isolated SMPS Designs A converter that works on the bench can still lose regulation when a battery sags, a load changes, or the input crosses the output voltage. The key is to choose a topology for the full operating range; not just the nominal numbers. In Part 2 of our series on Switched-Mode Power Supplies (SMPS), we compare four popular topologies; buck, boost, buck-boost, and isolated buck. We discuss when a buck is the natural fit, what to consider at light loads, and why a boost converter's right-half-plane zero affects its transient response and loop bandwidth. We also look at the input-voltage crossover that calls for buck-boost conversion, a scenario that can be easy to miss in battery-powered designs. RELATED SOLUTIONS: PART 1: Branching Out Beyond the Flyback- An Introduction to SMPS and the Decision Tree: https://wattsup.libsyn.com/branching-out-beyond-the-flyback SMPS Topologies Tips & Tricks Patch: https://www.we-online.com/files/pdf1/smps-topologies-and-tips-and-tricks.pdf Storage Applications: Power Inductors for SMPS Guide: https://www.we-online.com/components/media/o470289v410%20Filter-Storage%20Applications.pdf Listen to our PODCAST🎙️: https://www.we-online.com/en/news-center/podcast Follow us on LinkedIn: https://www.linkedin.com/company/wurth-elektronik (Americas) Follow us on LinkedIn: https://www.linkedin.com/company/wuerth-elektronik-group (Europe) Like us on Facebook: https://www.facebook.com/WurthElectronics/ (Americas) Like us on Facebook: https://www.facebook.com/Wuerth.Elektronik.Group/ (Europe) Follow us on X: https://x.com/WurthElectronic/ (Americas) Follow us on X: https://x.com/we_online (Europe) Follow us on Instagram: https://www.instagram.com/wurthelectronics (Americas) Würth Elektronik online: https://www.we-online.com/

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show.

0:00In the last episode, we walked through the topology decision tree: isolation, power level, AC or DC. The first decision is whether you need an isolated power supply, or whether a non-isolated supply will work. If you don't need isolation, non-isolated is where you want to be. It's stable, efficient, and scalable.

0:37No transformer, no optocoupler feedback loop, and no safety spacing to design around. It's a smaller, cheaper, more efficient path from input to output, for point-of-load rails, LED strings, or battery-powered devices. So which non-isolated scheme fits your input and output relationship? And why isn't the topology you already know always the safe choice?

1:19You're listening to Würth Elektronik's Watts Up Radio Podcast, talking about electronics and PCB design. Today we're continuing our series on switched-mode power supplies. There are four non-isolated topologies worth knowing well.

1:51Buck, boost, buck-boost, and isolated buck. Each suits a different relationship between input and output voltage. First, is your input reliably higher than your output across the entire operating range, with no exceptions? If yes, buck is almost always the right call. It's the workhorse for point-of-load conversion.

2:30A 12- or 48-volt bus can step down to 5 volts, 3.3 volts, or lower for logic and sensors. The relationship between duty cycle and output voltage is direct and well understood. Before committing, check how the buck behaves at light load. Buck converters are often characterized in continuous conduction mode.

3:13There, inductor current doesn't reach zero between switching cycles. At a low enough load, it can enter discontinuous mode. Then the duty-cycle-to-output relationship gets less straightforward, and a loop tuned for full load may respond sluggishly.

3:43Many systems spend significant time in low-power or standby states. Test across the operating scenarios; this isn't a reason to avoid buck. Next, boost is the answer when the input is reliably lower than the output across the whole range. Single-cell batteries boosting to 5 volts, LED strings, and power-factor-correction front ends are examples.

4:27For boost, plan for control-loop response speed. Energy reaches the output through a diode during switch off-time. When more current is demanded, the converter increases duty cycle. That briefly shortens the diode's conduction window. The output can dip a little further before stored inductor energy catches up on later cycles.

5:10That's the right-half-plane zero, a known feature of boost conversion, not a control-loop mistake. Boost generally calls for more conservative loop bandwidth than a buck doing a similar job. Test with load steps that resemble what the system will actually see. That helps keep the response from being a surprise.

5:54Buck-boost is for an input voltage that doesn't stay on one side of the target output. The classic single-switch version charges an inductor from the input, then discharges it into the output, inverting polarity. Non-inverting versions use four switches, with buck and boost stages back-to-back.

6:38That adds complexity and can reduce efficiency compared with either stage alone. It's easy to miss an input that sometimes sits above, and sometimes below, the output target. A battery design may use a plain buck because nominal voltage looks comfortably higher than the target.

7:23But battery voltage changes over its discharge curve. Sag under load or near end of discharge can put it below target. A buck can't make up the difference once that happens. The output stops regulating. A fresh battery may pass an early bench test, while the failure appears later in validation or in the field.

8:07Before choosing buck, check whether the source holds a fixed voltage or crosses the output target across its range. Isolated buck answers a more specific question: can you get a small isolated output without a full isolated converter? Start with a synchronous buck. Replace its inductor with a coupled inductor or transformer.

8:51Add a diode and capacitor to the secondary winding to derive an isolated output. This can suit modest isolated power, for example, bias power for an isolated gate driver or interface. The primary buck output is what the control loop regulates. The isolated output follows indirectly through the turns ratio.

9:34Its regulation depends on coupling, winding resistance, leakage inductance, rectifier drop, and changing loads. A turns ratio calculated for 5 volts doesn't guarantee a tightly regulated 5 volts in every operating condition.

10:05A voltage-sensitive rail may need more tolerance or a small secondary-side post-regulator. Galvanic isolation is not automatically safety-rated isolation. Meet the required insulation, creepage, and clearance requirements. Buck, boost, and buck-boost are relatively simple, but simple doesn't mean low stakes.

10:49Each topology works only if input and output behave as the topology assumes. Skipping that check can make a design that looked fine on the bench fail in the field. Next time, we'll cover isolated DC/DC converters: flyback, forward, and push-pull.

11:36We'll discuss where each topology makes sense, including why push-pull suits low-voltage applications. Thanks for listening. Find technical materials and all episodes in audio and video at we-online.com/podcast.

12:06Order components through REDEXPERT or the MyWE customer portal, contact your regional Würth Elektronik team, or use live chat. You're listening to Würth Elektronik's Watts Up Podcast. Thanks for tuning in.

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. [AUDIO ONLY!!] Branching Out Beyond the Flyback

    Oct 30, 202613 minAudio

    Part 1: An Introduction to SMPS and the Decision Tree Choosing a familiar power supply topology can save design time, but relying on it for every application may create avoidable tradeoffs in efficiency, cost, and...

    Credit the people on this episode

  2. Branching Out Beyond the Flyback

    Oct 30, 202613 minVideo

    Part 1: An Introduction to SMPS and the Decision Tree Choosing a familiar power supply topology can save design time, but relying on it for every application may create avoidable tradeoffs in efficiency, cost, and...

    Credit the people on this episode

  3. Patch Me If You Can! The No Redesign Approach to EMI Shielding

    Sep 30, 202614 minVideo

    Unexpected EMI does not always require a complete PCB redesign. This episode explains how the EMI Patch combines a conductive metal layer with a magnetic absorber to reduce interference in near field and far field...

    Credit the people on this episode

  4. [Audio Only] Patch Me If You Can!

    Sep 30, 202614 minAudio

    Unexpected EMI does not always require a complete PCB redesign. This episode explains how the EMI Patch combines a conductive metal layer with a magnetic absorber to reduce interference in near field and far field...

    Credit the people on this episode

  5. [AUDIO ONLY!!]- Mission: Impedance- Hybrid Capacitor Protocol

    Aug 28, 202613 minAudio

    When a DC/DC output stage needs bulk capacitance, aluminum electrolytic capacitors are often the default choice. But what happens when ripple current pushes you into paralleling multiple capacitors, lifetime...