On the early morning of March 28, 1979, a serious incident unfolded at the Three Mile Island 2 nuclear power plant near Middletown, Pennsylvania. Triggered by mechanical failures and compounded by critical human errors, the accidents severity remained uncertain for four days, affecting plant managers, government officials, and the public alike. This event not only raised alarm bells across the nation but also ignited international scrutiny regarding nuclear safety. In response to these alarming concerns, this Commission was established to investigate the incident and its far-reaching implications. (Summary from the preface) This episode includes AI-generated content.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

Speaker 1Section twelve of the Report of the President's Commission on the Accident at Three Mile Island. This is a LibriVox recording. All LibriVox recordings are in the public domain. For more information or to volunteer, please visit LibriVox dot org. Report of the President's Commission on the Accident at Three Mile Island. Account of the Accident, Part two, Wednesday, March twenty eighth, nineteen seventy nine. In the parlance of the electric power industry,

Speaker 1a trip means a piece of machinery stops operating. A series of feed water system pumps supplying water to tm I two's steam generators tripped on the morning of March twenty eighth, nineteen seventy nine. The nuclear plant was operating at ninety seven percent power at the time. The first pump trip occurred at thirty six seconds after four a m. When the pump stopped, the flow of water to the steam generators stopped. With no feed water being added, there

Speaker 1would soon be no steam, so the plant's safety system automatically shut down the steam turbine and the electric generator it powered. The incident at three Mile Island was two seconds old. The production of steam is a critical function of a nuclear reactor. Not only does steam run the generator to produce electricity, but also, as steam is produced, it removes some of the intense heat that the reactor water carries. When the feed water flow stopped, the temperature

Speaker 1of the reactor coolant increased. The rapidly heating water expanded the pressurizer level, The level of the water inside the pressurizer tank rose, and the steam in the top of the tank compressed. Pressure inside the pressurizer built to two thousand, two hundred fifty five pounds per square inch, one hundred pounds per square inch more than normal. Then a valve atop the pressurizer called a pilot operated Relief valve or

Speaker 1po r V, opened as it was designed to do, and steam and water began flowing out of the reactor coolant system through a drain pipe to a tank on the floor of the containment building. Pressure continued to rise, however, and eight seconds after the first pump tripped, tmi's reactor, as it was designed to do, scrammed its control rods automatically dropped down into the reactor core to halt its nuclear fission. Less than a second later, the heat generated

Speaker 1by the fission was essentially zero, but as in any nuclear reactor, the decaying radioactive materials left from the fission process continued to heat the reactor's coolant water. This heat was a small fraction, just six percent of that release during fission, but it was still substantial and had to be removed to keep the core from overheating. When the pumps that normally supply the steam generator with water shut down,

Speaker 1three emergency feed water pumps automatically started. Fourteen seconds into the accident. An operator in TM two's control room noticed the emergency feed pumps were running, He did not notice two lights that told him a valve was closed on each of the two emergency feed water lines, and thus no water could reach the steam generators. One light was covered by a yellow maintenance tag. No one knows why

Speaker 1the second light was missed. With the reactor scrammed and the pr V open, pressure in the reactor coolant system fell up to this point, the reactor system was responding normally to a turbine trip. The p o r V should have closed thirteen seconds into the accident, when the pressure dropped to two thousand, two hundred five pounds per square inch it did not. A light on the control room panel indicated that the electric power that opened the

Speaker 1PO r V had gone off, leading the operators to assume that that valve had shut. But the PO RV was stuck open and would remain open for two hours and twenty two minutes draining needed coolant water. An l OCA loss of coolant accident was in progress. In the first one hundred minutes of the accident, some thirty two thousand gallons, over one third of the entire capacity of the reactor coolant system, would escape through the p O

Speaker 1r V and out the reactor's let down system. Had that valve closed as it was designed to do, or if the control room operate had realized that the valve was stuck open and had closed a back up valve to stem the flow of coolant water, or if they had simply left on the plant's high pressure injection pumps, the accident at three Mile Island would have remained little more than a minor inconvenience for meted to a casual visitor.

Speaker 1The control room at TMI TiO can be an intimidating place, with messages coming from the loud speaker of the plant's paging system, panel upon panel of red, green, amber, and white lights, and alarms that sound or flash warnings many times each hour. Reactor operators are trained how to respond and to respond quickly in emergencies. Initial actions are ingrained, almost automatic, and unthinking. The burden of dealing with the

Speaker 1early crucial stages of the accident at Three Mile Island fell to four men. William Zeo, shift supervisor in in charge of both tm I one and tm I two, Fred scheiman shift foreman for tm I two, and two control room operators Edward Frederick and Craig Faust. Each had been trained for his job by met Ed and Babcock and Wilcox, the company that supplied TM two's reactor and nuclear steam system. Each was licensed by the Nuclear Regulatory Commission.

Speaker 1Each was a product of his training, training that did not adequately prepare them to cope with the accident at TM two. Indeed, their training was partly responsible for escalating what should have been a minor event into a potentially devastating accident. Frederick and Faust were in the control room when the first alarm sounded, followed by a cascade of alarms that numbered one hundred within minutes. The operators reacted quickly as trained to counter the turbine trip and reactor scram. Later,

Speaker 1Faust would recall for the Commission his reaction to the incessant alarms. I would have liked to have thrown away the alarm panel. It wasn't giving us any useful information. Zoo, working in a small glass enclosed office behind the operators, alerted the t M I one control room of the t M I two scram and called his shift foreman back into the control room. Scheimann had been overseeing maintenance on plant's number seven polisher, one of the machines that

Speaker 1removed dissolved minerals from the feed water system. His crew was using a mixture of air and water to break up resin that had clogged a resin transfer line. Later investigation would reveal that a faulty valve in one of the polishers had allowed some water to leak into the air controlled system that opens and closes the polisher's valves, and may have been a factor in their sudden closure just before the accident. This malfunction probably triggered the initial

Speaker 1pump trip that led to the accident. The same problem of water leaking into the polisher's valve control system had occurred at least twice before at TM two had met ed corrected the earlier Polisher problem. The March twenty eighth sequence of events may never have begun. With the PLRV stuck open and heat being removed by the steam generators, the pressure and temperature of the reactor coolant system dropped.

Speaker 1The water level also fell in the pressurizer. Thirteen seconds into the accident, the operators turned on a pump to add water to the system. This was done because the water in the system was shrinking as it cooled, thus more water was needed to fill the system. Forty eight seconds into the incident, while pressure continued falling, the water level in the pressurizer began to rise again. The reason at this point was that the amount of water being

Speaker 1pumped into the system was greater than the amount being lost through the POURV. About a minute and forty five seconds into the incident, because their emergency water lines were blocked, the steam generators boiled dry. After the steam generators boiled dry, the reactor coolant heated up again, expanded, and this helped send the pressurizer level up further. Two minutes into the incident, with the pressurizer level still rising, pressure in the reactor

Speaker 1coolant system dropped sharply. Automatically, two large pumps began pouring about a thousand gallons a minute into the system. The pumps, called high pressure injection HPI pumps, are part of the reactor's emergency core cooling system. The level of water in the pressurizer continued to rise, and the operators, conditioned to maintain a certain level in the pressurizer, took this to mean that the system had plenty of water in it. However,

Speaker 1the pressure of the reactor coolant system water was falling and its temperature became constant. About two and a half minutes after the HPI pumps began working, Frederick shut one down and reduced the flow of the second to less than one hundred gallons per minute. The falling pressure, coupled with a constant reactor coolant temperature after HPI came on, should have clearly alerted the operators that tm I two had suffered a loss of coolant accident and safety required

Speaker 1they maintain high pressure injection. The rapidly increasing pressurizer level at the onset of the accident led me to believe that the high pressure injection was excessive and that we were going to have a solid system, Frederick later told the commission. A solid system is one in which the entire reactor and its cooling system, including the pressurizer, are filled with water. The operators had been taught to keep the system from going solid, a condition that would make

Speaker 1controlling the pressure within the reactor coolant system more difficult and might damage the system. The operators followed this line of reasoning, oblivious for over four hours to a far greater threat that the loss of water from the system could result in uncovering the core. The saturation point was reached five and a half minutes into the accident. Steam bubbles began forming in the reactor coolant system, displacing the coolant water in the reactor itself. The displaced water moved

Speaker 1into the pressurizer, sending its level still higher. This continued to suggest to the operators that there was plenty of water in the system. They did not realize that water was actually flashing into steam in the reactor, and with more water leaving the system than being added, the core was on its way to being uncovered, and so the operators began draining off the reactor's cooling water through piping called the let down system. Eight minutes into the accident,

Speaker 1someone just who is a matter of dispute, discovered that no emergency feed water was reaching the steam generators. Operator Faust scanned the lights on the control panel that indicate whether the emergency feedwater valves are open or closed. He first checked a set of emergency feedwater valves designed to open after the pumps reached full speed. They were open. Next, he checked a second pair of emergency feedwater valves, called

Speaker 1the twelve valves, which are always supposed to be open except during a specific test of the emergency feedwater pumps. The two twelve valves were closed. Faust opened them, and water rushed into the steam generators. The two twelve valves were known to have been closed two days earlier, on March twenty sixth, as part of a routine test of the emergency feedwater pumps. A Commission investigation has not identified a specific reason as to why the valves were closed

Speaker 1at eight minutes into the accident. The most likely explanations are the valves were never reopened after the March twenty sixth test, or the valves were reopened and the control room operators mistakenly closed the valves during the very first part of the accident, or the valves were closed mistakenly from control points outside the control room after the test. The loss of emergency feed water for eight minutes had no significant effect on the outcome of the accident, but

Speaker 1it did add to the confusion, which distracted the operators as they sought to understand the cause of their primary problem. Throughout the first two hours of the accident, the operators ignored or failed to recognize the significance of several things that should have warned them that they had an open PORV and a loss of coolant accident. One was the high temperatures at the drain pipe that led from the PORV to the reactor coolant DRAAM tank. One emergency procedure

Speaker 1states that a pipe temperature of two hundred degrees fahrenheit indicates an open PORV. Another states that when the drain pipe temperature reaches one hundred thirty degrees fahrenheit, the block valve beneath it should be closed. But the operators testified that the pipe temperature normally registered high because either the porv or some other valve was leaking slightly. I have seen in reviewing logs since the accident, approximately one hundred

Speaker 1ninety eight degrees, Zeo told the commission, but I can remember instances before just over two hundred degrees. So Zeo and his crew dismissed the significance of the temperature readings, which Zoo recalled as being in the two hundred thirty degree fahrenheit range. Recorded data showed the range reached two hundred eighty five degrees fahrenheit. Zoo told the Commission that he regarded the high temperatures on the drain pipe as residual heat, knowing that the relief valve had lifted the

Speaker 1downstream temperature I would expect to be high, and that it would take some time for the pipe to cool down below the two hundred degree set point. At four eleven, a m an alarm signaled high water in the Containment Building sump, a clear indication of a leak or break in the system. The water, mixed with steam had come from the open po r V, first falling to the drain tank on the Containment building floor and d and finally filling the tank and flowing into the sump. At

Speaker 1four fifteen a m, a rupture disk on the drain tank burst as pressure in the tank rose. This sent more slightly radioactive water onto the floor and into the sump. From the sump, it was pumped to a tank in the nearby auxiliary building. Five minutes later, at four twenty a m. Instruments measuring the neutrons inside the core showed a count higher than normal, another indication unrecognized by the

Speaker 1operators that steam bubbles were present in the core and forcing cooling water away from the fuel rods. During this time, the temperature and pressure inside the containment building rose rapidly from the heat and steam escaping via the pr V and drain tank. The operators turned on the cooling equipment and fans inside the containment building. The fact that they failed to realize that these conditions resulted from a loss of coolant accident indicates a severe deficiency in their training

Speaker 1to identify the symptoms of such an accident. About this time, Edward Frederick took a call from the auxiliary building. He was told an instrument there indicated more than six feet of water in the containment building sump. Frederick queried the control room computer and got the same answer. Frederick recommended shutting off the two sump pumps in the containment building. He did not know where the water was coming from and did not want to pump water of unknown origin

Speaker 1which might be radioactive outside the containment building. Both sump pumps were stopped about four thirty nine a m. Before they were However, as much as eight thousand gallons of slightly radioactive water may have been pumped into the auxiliary building only thirty nine minutes had passed since the start of the axis. George Kunder, Superintendent of technical support at tm I two, arrived at the island about four forty five a m. Summoned by telephone. Kunder was duty officer

Speaker 1that day and he had been told t M I two had had a turbine trip and a reactor scram What he found upon his arrival was not what he had expected. I felt we were experiencing a very unusual situation because I had never seen pressurizer level go high and peg in the high range, and at the same time pressure being low. He told the commission. They have always performed consistently. Kunder's view was shared by the control

Speaker 1room crew. They later described the accident as a combination of events they had never experienced, either in operating the plant or in their training simulations. Shortly after five a m, t M I two's four or reactor coolant pumps began vibrating severely. This resulted from pumping steam as well as water, and it was another indication that went unrecognized that the reactor's water was boiling into steam. The operators feared the

Speaker 1violent shaking might damage the pumps, which force water to circulate through the core, or the coolant piping. Zoo and his operators followed their training. At five fourteen a m. Two of the pumps were shut down. Twenty seven minutes later, operators turned off the two remaining pumps, stopping the forced flow of cooling water through the core. There was already evidence by approximately six a m. That at least a few of the reactor's fuel rod claddings had ruptured from

Speaker 1high gas pressures inside them, allowing some of the radioactive gases within the rods to escape into the coolant water. The early warning came from radiation alarms inside the containment building. With coolant continuing to stream out the open porv and little water being added. The top of the core became uncovered and heated to the point where the zirconium alloy of the fuel rod cladding reacted with the steam to produce hydrogen. Some of this hydrogen escaped into the containment

Speaker 1building through the open porv and drain tank. Some of it remained within the reactor. This hydrogen and possibly hydrogen produced later in the day, caused the explosion in the containment building on Wednesday afternoon and formed the gas bubble that produced such great concern. A few days later, other TMI officials were now arriving in the tm two control room. They included Richard Dubiel, a health physicist who served as

Speaker 1supervisor of Radiation Protection and Chemistry, Joseph Logan, superintendent of TA two, and Michael Ross, Supervisor of operations for tm I one. Shortly after six a m. George Kunder participated in a telephone conference call with George Herbine, met ed's vice president for Generation, Gary Miller, TMI station manager and met ed's senior executive stationed at the nuclear facility, and

Speaker 1Leland Rogers, the Babcock and Wilcox site representative at TMI. The four men discussed the situation at the plant. In his deposition, Rogers recalled a significant question he posed during that call. He asked if the block valve between the pressurizer and the PORV a backup valve that could be closed if the PORV stuck open had been shot. Question. What was the response, Rogers? George's immediate response was I

Speaker 1don't know, and he had some some one standing next to the shift supervisor over back of the control room and sent that guy to find out if the valve block was shut. Question. You heard him give these instructions, Rogers, Yes, and very shortly I heard the answer come back from the other person to George, and he said, yes, the block valve was shut. The operators shut the block valve at six twenty two a m. Two hours and twenty two minutes after the pr V had opened. It remains, however,

Speaker 1an open question whether Rogers or someone else was responsible for the valve being closed. Edward Frederick testified that the valve was closed at the suggestion of a shift supervisor coming on to the next shift, but Frederick has also testified that the valve was closed because he and his fellow operators could think of nothing else to do to bring the reactor back under control. In any event, the loss of koland was stopped and pressure began to rise,

Speaker 1but the damage continued. Evidence now indicates the water in the reactor was below the top of the core at six fifteen a m. Yet, for some unexplained reason, high pressure injection to replace the water lost through the pr V and letdown system was not initiated for almost another hour. Before that occurred. Kunder Dubl and their colleagues would realize that they faced a serious emergency at tm I two.

Speaker 1In the two hours after the turbine trip, periodic alarms warned of low level radiation within the unoccupied containment building. After six a m. The radiation readings markedly increased. About six thirty a m, a radiation technician began surveying the TMI two auxiliary building using a portable detector, a task that took about twenty minutes, reported rapidly increasing levels of radiation up to one rem per hour. During this period,

Speaker 1monitors in the containment and auxiliary buildings showed rising radiation levels. By six forty eight am, high radiation levels existed in several areas of the plant, and evidence indicates as much as two thirds of the twelve foot high core stood uncovered at this time. Analyses and calculations made after the accident indicate temperatures as high as thirty five hundred to four thousand degrees fahrenheit or more in parts of the

Speaker 1core existed during its maximum uncovery. At six fifty four a m. The operators turned on one of the reactor coolant pumps, but shut it down nineteen minutes later because of high vibrations. More radiation alarms went off shortly before seven a m. Kunder and Zoo declared a site emergency required by tmi's emergency plan whenever some event threatens an uncontrolled release of radioactivity to the immediate environment. End of

Speaker 1section twelve. Recording by Maria Casper

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Castaways of Disappointment Island - Herbert Escott Inman

    Nov 21, 20267 hr 2 minAudio

    Castaways of Disappointment Island - Herbert Escott Inman. This episode includes AI-generated content.

    Credit the people on this episode

  2. Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on...

    Nov 14, 20265 hr 54 minAudio

    Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on Armed Services. This episode includes AI-generated content.

    Credit the people on this episode

  3. Appeal to the Religion, Justice, and Humanity of the British Empire for West Indies Slaves-William Wilberforce

    Oct 31, 20262 hr 17 minAudio

    "Appeal to the Religion, Justice, and Humanity of the British Empire for West Indies Slaves" by William Wilberforce is a powerful call to conscience, urging the British Empire to recognize the moral imperative of...

    Credit the people on this episode

  4. Four-Fifty Miles to Freedom-Maurice Andrew Brackenreed Johnston, Kenneth Darlaston Yearsley

    Oct 25, 20266 hr 51 minAudio

    "Four-Fifty Miles to Freedom" by Maurice Andrew Brackenreed Johnston and Kenneth Darlaston Yearsley invites listeners to explore themes of resilience and the quest for liberation. This compelling narrative delves into...

    Credit the people on this episode

  5. Safeguarding children pediatric medical countermeasure research-Presidential Commission for the Study of Bioethical Iss

    Oct 24, 20265 hr 41 minAudio

    "Safeguarding Children: Pediatric Medical Countermeasure Research" by the Presidential Commission for the Study of Bioethical Issues delves into the critical intersection of pediatric health and ethical considerations...

    Credit the people on this episode