Skip to content
PodSubs
ShowsPeopleGuestsJobsNewsEvents
More
BlogPodCred
Menu
ShowsPeopleGuestsJobsNewsEventsBlogPodCredNetworksSign in
Join nowSign in
  • Shows
  • People
  • Jobs
  • News
  • More
    • Guests
    • Events
    • Blog
    • PodCred
    • Networks
    Join nowSign in

Structure Talk

Structure Talk artwork

Fire Safety Insights (with Jamie Smith and AJ Neis)

Oct 26, 202656 minAudio

To watch a video version of this podcast, click here: https://youtu.be/acuCH3qjeEc In this episode of the Structure Talk podcast, Reuben Saltzman joined by co-host Eric Houseman, talks with Jamie Smith, Deputy Chief of the St. Paul Fire Department, and AJ Neis, St. Paul’s Fire Code Official, about residential fire safety, smoke and carbon monoxide alarm requirements, and common household fire hazards. They discuss the growing risks associated with lithium-ion batteries, practical charging precautions, and seasonal fire prevention tips involving space heaters, holiday decorations, and cooking. The conversation also highlights why homeowners and inspectors should understand the intent behind fire codes and consider safety improvements beyond minimum requirements. Explore Upcoming Inspector Empire Builder Events: https://www.iebcoaching.com/events Takeaways Smoke alarms are not required in garages under the guidance discussed for St. Paul, but interconnected heat alarms can provide an additional layer of protection. Fire code requirements and interpretations can vary by jurisdiction. Always confirm requirements with the local authority having jurisdiction. Test alarms regularly, replace batteries as needed, and replace expired units. Hardwired alarms also need functioning battery backups. Carbon monoxide alarms are generally placed within 10 feet of sleeping rooms under the requirements discussed. The 10-foot distance is a minimum placement standard, not a protective bubble. Use undamaged, approved chargers; charge devices on hard surfaces; keep them away from combustible materials; monitor charging; and unplug them when fully charged. Stop using batteries that are swollen, damaged, or otherwise showing signs of deterioration. Keep space heaters at least three feet from combustible materials, plug them directly into wall outlets, and use models with automatic shutoff and appropriate safety listings. Replace frayed, chewed, or damaged cords. Never ignore repeatedly tripping breakers or replace a breaker with one rated above the circuit's capacity. Avoid leaving cooking unattended. Remember the fire safety reminder: “When you cook, stay and look.” Home inspectors can strengthen their reports by explaining why a condition matters and recommending practical improvements that provide additional protection. Chapters 00:00 - Introduction and Guest Welcome 04:37 - Meet Jamie Smith and AJ Neis: Fire Service Roles and Experience 09:45 - Are Smoke Alarms Required in Garages? 14:10 - Heat Alarms and Choosing Smoke Alarm Types 19:03 - Hardwired Smoke Alarms and St. Paul Requirements 23:57 - Garage Fires and the Growing Risk of Lithium-Ion Batteries 27:41 - Safe Battery Charging Practices 33:44 - Why You Shouldn't Charge Devices in Bed or Leave Them Plugged In 36:33 - Carbon Monoxide Alarm Placement: Understanding the 10-Foot Rule 42:19 - Code Minimums vs. Additional Home Safety Measures 44:34 - What Home Inspectors Should Communicate About Fire Safety 47:12 - Seasonal Fire Risks: Space Heaters, Electrical Safety, and Holiday Decorations 50:38 - Space Heater Precautions, Electrical Warning Signs, and Christmas Trees 52:51 - Cooking Fires and the “Stay and Look” Reminder 53:28 - Heating Pads, Damaged Cords, and Electrical Device Safety 57:20 - Final Thoughts and Wrap-Up

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Home Inspector Test House: unbeatable training

    Nov 16, 202626 minAudio

    To watch a video version of this podcast, click here: https://youtu.be/I0g_-Bxsizc In this episode of the Structure Talk podcast, Reuben Saltzman and Eric Houseman explain how their annual “test house” transforms a real...

    Credit the people on this episode

  2. Post-covid remorse and skipped home inspections (with Michael Bartus)

    Nov 9, 20261 hr 6 minAudio

    To watch a video version of this podcast, click here: https://youtu.be/0JY0DoqAt34 In this episode of the Structure Talk podcast, Reuben Saltzman and Eric Houseman joined with longtime Twin Cities REALTOR Michael Bartus...

    Credit the people on this episode

  3. Home Inspection Software to blow your mind (with Hometrace)

    Nov 2, 202654 minAudio

    To watch a video version of this podcast, click here: https://youtu.be/0nv6QgYTy50 In this episode of the Structure Talk podcast, Reuben Saltzman and Eric Houseman welcome Nick Roberts and Sam Despres, the team behind...

    Credit the people on this episode

  4. How RESNET could be better (with Trent Fuller)

    Oct 12, 202643 minAudio

    To watch a video version of this podcast, click here: https://youtu.be/QptKPRH_2h4 In this episode of the Structure Talk podcast, Reuben Saltzman and Eric Houseman welcome Trent Fuller to discuss construction-phase...

    Credit the people on this episode

  5. Recent Inspection Findings

    Oct 5, 202648 minAudio

    To watch a video version of this podcast, click here: https://youtu.be/DIzBbXZGbWo In this episode of the Structure Talk podcast, Reuben Saltzman is joined by Eric Houseman, filling in as co-host while Tessa Murry is on...

    Credit the people on this episode