Skip to content
PodSubs
ShowsPeopleGuestsJobsNewsEvents
More
BlogPodCred
Menu
ShowsPeopleGuestsJobsNewsEventsBlogPodCredNetworksSign in
Join nowSign in
  • Shows
  • People
  • Jobs
  • News
  • More
    • Guests
    • Events
    • Blog
    • PodCred
    • Networks
    Join nowSign in

Silent Sentinels- Protective Relays for A-C and D-C Systems

Silent Sentinels- Protective Relays for A-C and D-C Systems artwork

006 - Direct-Current Systems

Mar 5, 20265 minAudio
ShareXLinkedInFacebookWhatsAppEmail

Discover Silent Sentinels, a groundbreaking exploration into the world of protective relays and the intricate schemes that safeguard the generation, transmission, and distribution of electric power. This book stands as one of the earliest comprehensive resources on the subject, revealing how, despite the rapid technological advancements over the past century, the core principles of protective relays remain steadfast. Join Rick Jay as he navigates through the historical and technical landscape of electrical protection systems, providing insights that are both timeless and essential for understanding modern power infrastructure. This episode includes AI-generated content.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

Speaker 1Chapter four of Silent Sentinels by Westinghouse Electric and Manufacturing Company. This LibriVox recording is in the public domain. Direct current systems. The direct current systems of today, though small in comparison with the alternating current systems, offer relay problems. Equally important, comparable to the service demanded of other public utilities, is at which congested cities demand from street railway companies. The growth and interconnection of some of these systems have created

Speaker 1a demand for adequate direct current relay protection. This demand for service brought about both the development of service restoring equipment and the supervision of feeder apparatus by supervisory control. Protection against overcurrents caused either by accidental faults on feeders or lines, or by excessive overloads onlines can be affected by the use of overcurrent relays. The short circuit detector type of equipment meeting the demands of railway systems, permits heavy overloads due to acceleration, but gives protection upon the

Speaker 1occurrence of a short circuit on the line. Service restoring system as in the case of alternating current service, the question of continuity of service often makes necessary some sort of device to restore service after it has been interrupted. Where a feeder has been tripped out because of a fault, it may sometimes be necessary to provide means for automatically reclosing the breaker several times, allowing a definite interval of time between each reclosing. Thus, if the fault is of

Speaker 1a transient nature and clears itself quickly, the breaker will remain closed and service will be continued on the line. However, if the fault is of a permanent nature, the breaker will open each time it is reclosed until the specified number of reclosures have occurred, and then it will remain open permanently, indicating that the line requires attention. Another method used for service restoring is to have a relay which has included an it designed characteristics, whereby it discriminates between a good and a bad feeder. In this case, the

Speaker 1feeder is opened under overcurrent or short circuit conditions and the breakers reclose automatically as soon as the excessive load is removed. After the breaker has been opened, it may be reclosed by a resistance measuring relay. This relay determines when the fault has been cleared sufficiently to allow the circuit breaker to be closed with safety. When continuity of services of great importance, and when the capacity behind the feeder is large, it is desirable to have the breaker remain closed, except in cases of actual short circuits or

Speaker 1violent overloads. Operators of large urban railway systems demand this class of service as it permits heavy peaks for acceleration of the cars and prevents untimely interruption of the service. Nevertheless, in meeting this demand, the feeder circuits must be protected against short circuits and heavy overcurrents. The short circuit detector type of equipment provides this protection without interrupting the circuit on ordinary overloads. Except for heavy railway service, it is usually desirable to open a circuit on a definite overcurrent.

Speaker 1For this application, the overcurrent type of equipment with an overcurrent relay is used instead of the short circuit detector. The overcurrent setting is usually for instantaneous tripping, but occasionally a time element is provided protection of direct current apparatus. The protection of the direct current apparatus might be classified as protection against overcurrent, reversed current, and over temperature. In most cases, such protection on motors and generators is secured by means of circuit breakers equipped with necessary overcurrent or

Speaker 1reverse current coils or by fuses of suitable capacity. In many installations, however, it is found necessary to use a protective relay in order to secure the needed accuracy and reliability of protection. In such cases, the D or to overcurrent relay is used, and in cases where protection is really required against reverse current, the d reverse current relay is applicable. Over temperature protection of direct current apparatus is obtained in a manner similar to that described under alternating

Speaker 1current apparatus. The BD oil filled thermal relay is used largely for motor protection, while in some cases where it is possible to have exploring coils in the windings, the DT temperature relay is used electrochemical work when a line supplies a load. For such work as electrochemical processes where a reversal of polarity is extremely dangerous, it is sometimes necessary to supply a highly sensitive relay which serves to disconnect the circuit when any condition shows that the polarity

Speaker 1is liable to reverse the A polarity directional relay has been used very successfully for this purpose, fulfilling the protective requirements and passing the underwriter's inspection. The sensitivity and design of this relay are such that the contacts will be closed upon any reversal of the polarity of the curve to which it is connected, or upon a fall in the voltage to below twenty percent of normal value. End of Chapter four

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on...

    Nov 21, 20265 hr 54 minAudio

    Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on.... This episode includes AI-generated content.

    Credit the people on this episode

  2. Silent Sentinels Protective Relays for A-C and D-C Systems-Westinghouse Electric and Manufacturing Company

    Nov 14, 20264 hr 27 minAudio

    "Silent Sentinels Protective Relays for A-C and D-C Systems" by the Westinghouse Electric and Manufacturing Company is a pivotal exploration of the technology that safeguards electrical systems. This book delves into...

    Credit the people on this episode

  3. Silent Sentinels Protective Relays for A-C and D-C Systems-Westinghouse Electric and Manufacturing Company

    Oct 31, 20264 hr 27 minAudio

    "Silent Sentinels Protective Relays for A-C and D-C Systems" by the Westinghouse Electric and Manufacturing Company is a pivotal exploration of the technology that safeguards electrical systems. This book delves into...

    Credit the people on this episode

  4. Twentieth Century Inventions A Forecast-George Sutherland

    Oct 30, 20266 hr 42 minAudio

    "Twentieth Century Inventions: A Forecast" by George Sutherland presents a visionary exploration of technological advancements anticipated in the 20th century. This thought-provoking work delves into the possibilities...

    Credit the people on this episode

  5. Seeking a Human Spaceflight Program Worthy of a Great Nation-Review of U.S. Human Space Flight Plans Committee

    Oct 29, 20269 hr 8 minAudio

    "Seeking a Human Spaceflight Program Worthy of a Great Nation" is an insightful review of the U.S. Human Space Flight Plans Committee, examining the aspirations and strategies for America's human space exploration...

    Credit the people on this episode