Silent Sentinels- Protective Relays for A-C and D-C Systems

Silent Sentinels- Protective Relays for A-C and D-C Systems artwork

010 - Application Chart of Westinghouse Relays

Mar 5, 202636 minAudio
ShareXLinkedInFacebookWhatsAppEmail

Discover Silent Sentinels, a groundbreaking exploration into the world of protective relays and the intricate schemes that safeguard the generation, transmission, and distribution of electric power. This book stands as one of the earliest comprehensive resources on the subject, revealing how, despite the rapid technological advancements over the past century, the core principles of protective relays remain steadfast. Join Rick Jay as he navigates through the historical and technical landscape of electrical protection systems, providing insights that are both timeless and essential for understanding modern power infrastructure. This episode includes AI-generated content.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

Speaker 1Chapter eight of Silent Sentinels by Westinghouse Electric and Manufacturing Company. This LibriVox recording is in the public domain. Application chart for Westinghouse Protective and Control relays General applications. Application to give signal at over or under AC voltage type C

Speaker 1V rating contacts normally closed above fifty five voltes ninety volts, one hundred and forty votes or two hundred and eighty volts. Contacts normally closed below eighty volts or one hundred and sixty volts. Time characteristics inverse operating principal induction description AC over and under voltage. Application to disconnect AC apparatus upon

Speaker 1overcurrent type C rating four to twelve amps four to sixteen amps. Time characteristics inverse with definite minimum operating principle induction description AC overcurrent fold amps required to operate sixteen. Application to disconnect AC apparatus upon overcurrent type CoA rating

Speaker 1four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description type C with current indias cater fold amps required to operate sixteen. Application to disconnect AC apparatus upon overcurrent applicable where only low ratio bushing. Type

Speaker 1current transformers are available. Type l ECO rating four to twelve amps. Time characteristics inverse with definite minimum. Operating principle induction description AC overcurrent volt amps required to operate two Application to protect AC installation against excessive powerflow in reverse

Speaker 1direction normal voltage. Applicable on regenerative systems. Type C W rating five amp seventeen one hundred and twenty five volts fifty to three hundred watts one hundred to six hundred watts. Time characteristics inverse operating principle induction description AC reverse power application to protect windings of AAC apparatus from overheating. Applicable

Speaker 1where exploring coils may be installed in windings. Operates only on excess current and temperature. Type c T rating five amps. Time characteristics inverse operating principle induction description AC over temperature application to protect windings of apparatus from overheating. Oil Feld

Speaker 1thermal relay operating from current transformer short time type BA rating two to fifteen amps. Time characteristics ten seconds to ninety minutes. Operating principle differential expansion description AC thermal bolt amps required to operate. Sixteen to fifty two volt amps at five amps. Application to protect windings of apparatus from overheating.

Speaker 1Oil felled thermal relay operating from current transformer. Long time type BA rating two to fifteen amps. Time characteristics ten seconds to one hundred and twenty minutes. Operating principle differential expansion description AC D thermal fold amps required to operate sixteen to fifty two fold amps at five amps. Application

Speaker 1to protect windings of apparatus from overheating. Oil felled thermal relay operating from current transformer, long time type BF rating one to sixty amps. Time characteristics inverse operating principal differential expansion description AC or DC thermal application to protect windings

Speaker 1of apparatus from overheating. Cartridge type thermal relay type b K rating sixty two one hundred amps. Time characteristics inverse operating principal differential expansion description AC Z or DC thermal application to protect windings of apparatus from overheating. Cartridge type thermal relay hand reset type b H rating one to

Speaker 1one hundred amps. Time characteristics, inverse operating principle differential expansion description AC or DC thermal application to protect windings of DC apparatus from overheating. Applicable where exploring coils may be provided. Type DT rating special time characteristics inverse operating principle moving

Speaker 1coil description DC over temperature application, oil filled thermal relay operating from bus, current shunt or interpol drop. Short time type BD rating two to fifteen AMS, time characteristics ten seconds to ninety minutes. Operating principle. Differential expansion description DC over temperature application, oil filled thermal relay operating from bus,

Speaker 1current shunt or interpol drop. Long time type BD rating two to fifteen AMS, time characteristics ten seconds to one hundred and twenty minutes. Operating principle differential expansion description DC over temperature application to protect bearings of rotating machines from overheating. Type HM rating one hundred degrees celsius operating principle. Volatile

Speaker 1liquid description over temperature application to protect resistant scrids from overload. Auto substation control type h N rating one hundred and fifty degrees celsius, three hundred degrees celsius operating principle. Volatile liquid description over temperature application type generators application to protect

Speaker 1against excessively high voltage upon sudden clearance. Of short circuit used with vibrating type voltage regulator type c V rating contacts normally closed above fifty five volts. Time characteristics. Inverse operating principle induction description rates on under voltage. Application to disconnect AC generator in case of fault in winding differential

Speaker 1protection type CA rating five amps. Time characteristics. Instantaneous operating principle induction description AC current application to disconnect AC generator in case of fault in winding differential protection type l E C rating zero point five to two point five amps.

Speaker 1Time characteristics inverse with definite minimum operating principle induction description AC current fault amps required to operate two applic to limit the power fed into system by generators in small substations, type c W rating five amps, seventy and one hundred and twenty five volts fifty to three hundred watts one

Speaker 1hundred to six hundred watts time characteristics. Inverse operating principle induction description AC overpower application to protect three wirre DC generator against excessive unbalanced current, type T rating forty to eighty millivolts. Time characteristics. Instantaneous operating principle armature description DC

Speaker 1overcurrent application type converters. Application to prevent starting of SIN converter on low voltage automatic substation. Type c V rating, special time characteristics inverse operating principle induction description AC over or under voltage. Application to prevent operation on single phase

Speaker 1or on badly unbalanced phases. Type CM rating two to six amps. Time characteristics inverse with definite minimum operating principle induction description balanced phase current type c Q rating two to six amps, sixty cycle time characteristics inverse with definite minimum operating principle induction description balance phase current volt amps

Speaker 1required to operate twenty Application to prevent converters from running inverted reverse DC current type D rating fifty millivolts time characteristics, inverse operating principle moving coil description d C reverse current application to disconnect converter when flashover occurs. Type MF rating

Speaker 1one hundred amps, DC time characteristics, instantaneous operating principle armature description d C overcurrent flash relay application type motors, application to disconnect with AC motors upon fault in voltage. Type CV rating contexts normally closed above fifty five volts, ninety votes,

Speaker 1one hundred and forty voltes two hundred and eighty volts. Time characteristic inverse operating principle induction description AC under voltage application to disconnect AC motors in case of fault in Windings. Differential protection type CA rating five amps. Time characteristics instantaneous

Speaker 1operating principle induction description AC current application to disconnect AC motors in case of fault in Windings. Differential protection type l ECO rating zero point five to two point five amps. Time characteristics inverse with definite minimum operating principle induction description

Speaker 1AC overcurrent volt amps required to operate two. Application to prevent AC motors from drawing excess power from line. Normal voltage type c W rating five amps, seventy to one hundred and twenty five volts fifty to two hundred watts one hundred to six hundred watts. Time characteristics. Inverse operating

Speaker 1principal induction description AC reverse power application to prevent AC motor from reach turning over power to line when it is being run by a load. Type c W rating five amps, seventy to one hundred and twenty five volts fifty to three hundred watts, one hundred to six hundred

Speaker 1watts time characteristics inverse operating principle induction description. AC overpower application to prevent polyphase AC motors from operating single phase or with badly unbalanced phases. Type c M rating two to six amps. Time characteristics inverse with definite minimum operating

Speaker 1principle induction description. Phase current balance or phase failure. Application to prevent poly phase AC motors from operating single phase, reverse phase, or with badly unbalanced phases. Type c Q rating two to six amps. Time characteristics inverse with definite minimum operating principle induction description phase current balance or phase

Speaker 1failure foolt amps required to operate twenty Application to prevent starting poly phase induction motors, single phase or with reversed phase. Type c P rating one hundred and ten or two hundred and twenty volts. Time characteristics inverse operating principle induction description.

Speaker 1Reverse phase application to disconnect polyphase motors upon phase reversal type CP rating one hundred and ten or two hundred and twenty volts. Time characteristics inverse operating principle induction description. Reverse phase application transformers application to disconnect transformers upon over current.

Speaker 1Applicable where only low ratio bushing type current transformers are available. Type L E co O rating four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description AC over current bold amps required to operate. Two Application to disconnect high voltage transformers upon overcurrent, applicable on circuits

Speaker 1carrying approximately less than one hundred amps. Type C B rating four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description AC overcurrent vault amps required to operate. Forty four Application to disconnect transformers in case of vault in winding differential protection type CA rating five

Speaker 1to ten amps. Time characteristics instantaneous operating principle induction description AC current. Application to disconnect transformers in case of fault in winding differential protection type CO rating four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description

Speaker 1AC overcurrent bolt amps required to operate. Sixteen Application to protect windings from overheating thermostat type h M rating one hundred degrees celsius operating principle. Volatile liquid description over temperature application to protect windings from overheating. Exploring coil type CT

Speaker 1rating five amps, operating principle induction description over temperature application transmission lines. Application for feeder protection from overcurrent with pilot wire type C rating zero point five to one point five amps. Time characteristics inverse with definite minimum operating principle

Speaker 1induction description AC overcurrent volt amps required to operate. Sixteen Application to cut out section of transmission line where sc occurs line sectionalizing Type C four to twelve amps four to sixteen amps. Time characteristics inverse with definite minimum operating

Speaker 1principle induction description AC over current volt amps required to operate. Sixteen Application to cut out section of transmission line where sc occurs line sectionalizing Type CoA rating four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description

Speaker 1type CO with current indicator volt amps required to operate. Sixteen Application to cut out short circuited sections of transmission line line. Sectionalizing applicable where only low ratio bushing type current transformers are available. Type L E C rating four to twelve amps. Time characteristics inverse with definite minimum operating

Speaker 1principle induction description AC overcurrent volt amps required to operate. Two Application to cut out faulty section of high voltage transmission line upon overcurrent. Applicable on circuits carrying less than one hundred amps. Type c B rating four to twelve amps. Time characteristics inverse with definite minimum operating principle induction description

Speaker 1AC over current vault amps required to operate forty four Application to cut out faulty line from group of parallel feeders differential current type c D rating three to seven amps. Time characteristics inverse with definite minimum operating principle induction description AC selective differential current voltamps required to operate. Seven Application

Speaker 1to cut out faulty sections of transmission lines operates according to distance from vault type c Z rating seventy to one hundred and twenty five volts four to thirty three amps. Time characteristics direct with distance operating principle induction description distance or impedance. Voltamps required to operate. KERR L five voltamps

Speaker 1voltage L sixteen voltamps. Application to cut out short circuited section of transmission line with reverse power flow. Applicable at substation end of feeds. Type CR rating four to twelve amps, one hundred and twenty five volts. Time characteristics inverse with definite minimum operating principle induction description AC directional current volt

Speaker 1amps required to operate current L seventeen voltage L twenty five. Application to cut out short circuited section of transmission line with reverse power flow. Applicable at substation end of feeders. Type CRA rating four to twelve amps, one hundred and twenty five volts. Time characteristics inverse with definite minimum operating

Speaker 1principle induction description Type c R with current indicator volt ams required to operate current L seventeen voltage L twenty five. Application to cut out short circuited section of transmission line with reverse power flow. Applicable at substation end of feeds. Type c Z with directional element rating seventy to one

Speaker 1hundred and twenty five vaults four to thirty three amps. Time characteristics direct with distance operating principle induction description direction plus distance volt amps required to operate current L seven voltage L thirty app Application to cut out short circuited section of transmission lines with reverse power flow. Applicable at

Speaker 1substation end of feeders or only low ratio bushing type transformers are available. Type L e CR rating four to twelve amps one hundred and twenty five volts. Time characteristics inverse with definite minimum operating principle induction description. AC directional current volt amps required to operate kernel two voltage L

Speaker 1twenty five application to cut out grounded section of transmission line line. Sectionalizing applicable on systems with neutral grounded through high resistance type l e C rating zero point five to two point five amps. Time characteristics inverse with definite minimum operating principle induction description AC overcurrent bolt amps required

Speaker 1to operate. Two application to cut out grounded line from group of parallel feeders. Differential neutral current type c D rating zero point five to one point two amps. Time characteristics inverse with definite minimum operating principle induction description AC selective differential current bolt amps required to operate. Two. Application

Speaker 1to cut out grounded line upon reversal of power flow type l e CR rating zero point five to two point five amps, one hundred and twenty five volts. Time characteristics inverse with definite minimum operating principle induction description. AC directional current folt amps required to operate two application to

Speaker 1disconnect grounded lines on solidly grounded neutral and low resistance grounded neutral systems type c Z rating seventy and one hundred and twenty five vaults four to thirty three amps. Time characteristics, direct with distance operating principle induction description distance

Speaker 1or impedance fault amps required to operate current L five voltage L sixteen application automatic network relay sectionalizing low voltage networks type c N rating one hundred and twenty volts. Time characteristics, inverse operating principal induction description network relay application.

Speaker 1Auxiliary application to trip breaker with AC current from current transformers type b T rating five amps. Time characteristics, instantaneous operating principle, plunger description, current transfer volt amps required to operate. Twenty eight Application to control tripping of circuit breaker where

Speaker 1heavy current is required. Type twenty C rating one hundred and twenty five to two hundred fifty volts, seventy five to forty amps. Time characteristics, instantaneous operating principal hinged armature description contactor. Application to control tripping of circuit breaker where heavy current is required. Type thirtyh C rating one hundred

Speaker 1and twenty five to two hundred fifty volts one hundred and fifty to seventy five amps. Time characteristics, instantaneous operating principle, hinged armature description contactor application to prevent holding circuit breakers closed on short circa type S one rating one hundred and twenty five to two hundred and fifty volts. Time characteristics,

Speaker 1instantaneous operating principle, hinged armature description, trip free application to introduce a definite time delay in switching operations type c V rating special time characteristics, inverse operating principle. Induction description AC voltage application to control time of switching operations. Time

Speaker 1delay type GK rating one hundred and ten volts three to forty minutes. Time characteristics, definite operating principle, motor operated description long time delay application. Auxiliary multicontact relays for control circuits for continuous service on AC or DC type AMPC

Speaker 1rating eight twelve, sixteen, twenty five thirty two fifty sixty two one hundred and ten one hundred thirty two hundred and fifty volts DC sixty two one hundred and ten one hundred and thirty two hundred and twenty four hundred and forty volts AC time characteristics. Instantaneous operating principal hinged armature description. Multiple contactorvoldams required to operate two wattsman eight wattsmax.

Speaker 1Twenty five voldams. Application auxiliary multi contact relays for control circuits for intermittent service on DC only. Type M rating twelve fifty, one hundred and twenty five two hundred and fifty volts DC time characteristics. Instantaneous operating principle. Hinged armature description, multiple contactor volt amps required to operate two watts men

Speaker 1eight wattsmax. Twenty five volt amps. Application Auxiliary control and interlocking relays for switchboard control and signal work. Instant automatic reset type OA rating twelve fifty, one hundred and ten two hundred and fifty volts DC time characteristics. Instantaneous operating principle. Plunger description contact making application, auxiliary control and interlocking relays

Speaker 1for switchboard control and signal work. Hand reset typel and unlashing coil type OX rating one hundred ten to two hundred twenty AC twelve fifty one hundred and ten two hundred and fifty volts DC time characteristics. Instantaneous operating principle Plunger description, contact making application, auxiliary control and interlocking relays

Speaker 1for switchboard control and signal work holding coil type OS rating twelve fifty one hundred and ten two fifty volts DC time characteristics, Instantaneous operating principle. Plunger description, contact making application, banked, multi contactor supervisory control type m S rating special time characteristics,

Speaker 1definite description supervisory group of contacts. Application indicator to indicate when relay has functioned, type C rating zero point one and one amps time characteristics, instantaneous operating principle, hinged armature description, operation indicator application frequency relay to actuate an alarm or

Speaker 1trip a circuit upon a rise or fall in frequency type r F rating one hundred and ten bolts rated frequency time characteristics. Instantaneous operating principal plunger description two coils with balanced lever. End of Chapter eight

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on...

    Nov 21, 20265 hr 54 minAudio

    Report of the Inquiry into the Role and Oversight of Private Security Contractors in Afghanistan - United States Senate Committee on.... This episode includes AI-generated content.

    Credit the people on this episode

  2. Silent Sentinels Protective Relays for A-C and D-C Systems-Westinghouse Electric and Manufacturing Company

    Nov 14, 20264 hr 27 minAudio

    "Silent Sentinels Protective Relays for A-C and D-C Systems" by the Westinghouse Electric and Manufacturing Company is a pivotal exploration of the technology that safeguards electrical systems. This book delves into...

    Credit the people on this episode

  3. Silent Sentinels Protective Relays for A-C and D-C Systems-Westinghouse Electric and Manufacturing Company

    Oct 31, 20264 hr 27 minAudio

    "Silent Sentinels Protective Relays for A-C and D-C Systems" by the Westinghouse Electric and Manufacturing Company is a pivotal exploration of the technology that safeguards electrical systems. This book delves into...

    Credit the people on this episode

  4. Twentieth Century Inventions A Forecast-George Sutherland

    Oct 30, 20266 hr 42 minAudio

    "Twentieth Century Inventions: A Forecast" by George Sutherland presents a visionary exploration of technological advancements anticipated in the 20th century. This thought-provoking work delves into the possibilities...