Rusty's Air Conditioning: guys, welcome back to the podcast. I got Sean Thompson on here. so I think we're gonna kick today's podcast off, talk about some items that you guys may experience, see if we can help you guys out over here. So gonna start out, Sean. Why do AC systems freeze up? Two reasons really. You have airflow and or lack thereof and refrigerant problems. Airflow, dirty filters. That's a big one. Or like collapse ducks, that kind of thing. And then refrigerant is usually like a metering device backing up. That's those are those are really the Yeah, so for like you guys listen at home homeowners, so like right, airflow, like you said, so air filters if they're really clogged up. Change every thirty days. If not, that's gonna basically cause that unit to freeze up where you can have an ice block in the coil inside. the other thing Sean was saying there is if like return ducks or collapse, we've seen where basically they collapse in on these on themselves, right? yeah. Dampers too. There's a lot of new damp houses out there with So a lot of new houses out here in in Phoenix that are built. There you got one system on a zone that has damper controls that open and shut airflow to diff different sections of the house. We see those fail a lot during the humidity time of there, basically monsoon, so those end up failing. Right. Basically if they're shutting, you're not getting that airflow out there. Those coils can freeze up. That's another sign over there. airflow, which is you know, evaporator coil can get really dirty. So I mean that's part of airflow, but so like just standard maintenance. So if you guys are not doing that, that's another reason that those can get frozen up is the evaporator coil getting plugged up with dirt, debris. pet hair, pet dandruff, whatever, you know, you want to name it. Because people don't change their filters. Yes. So filters on there. the other one is is big issue is the airflow issue, right? So a lot of times, you know, you might get a brand new unit that's installed. so you know, plenums, which you know, we'll define what that is real fast. It's basically the box that goes on the back of the unit and the front of the unit. Sometimes those things are undersized or the contractor never even put one on. Those should be put on. Those ha help with static pressures and stuff like that. So static pressure is a big thing when these things get installed. The engineers want the static pressures to be at a certain number. And depending on what type of unit you have, those readings should be get basically you should take those readings. But you could put those plenums on, but if you don't have the right size return size on there, so the flex is not you know, wrong size, that can cause an issue as well. Too small. Too small. Most of the time, it's always too small. Nor Normally yeah, your your returns ended up being too small. Supply ducts, you know, you know, that they're not the right size on there. So that's another big issue up there. Yeah. I I think it's the statistic is like seventy percent of homes have undersized ductwork. I think it is what that is. Yeah, I think it's yeah, I think SRP right around SRP says, well, I think thirty per thirty percent of homes are leaking, thirty, forty forty percent of homes are leaking airflow. So airflow is a big one. So that's the thing. Like, yeah, you know, you might be getting these units installed. the the home builders put, you know, so where you change your filters at, there's two different types of grills. There's stamp face grills and then there's bar type grills. You know, preferably bar type grills should be installed, especially if you only have one return in the house. It allows more airflow to get inside the unit so the unit is running more efficient. Now that we've switched over to this new refrigerant, R R thirty two and four fifty-four B, you know, you talk to a lot of the the trainings that me and Sean have gone to, you talk to the the reps that are, you know, helping you on technical diagnosis and the big thing that me and Sean have seen and in red and and all these things is they all say airflow, right? So these newer systems are just requiring better airflow to work. So if you guys are experiencing your unit working harder or it's freezing up, like Sean said, number one thing is going to be airflow. So that's gonna that that's gonna cause it. And then you know we talked about refrigerant. So metering device, TXV Most of you know, there used to be pistons in a lot of units, you know, just basically allowed enough refrigerant to get in the coil at a consistent rate. These new things are actually metering on there, they're TXV thermal expansion valves. Those do fail. So basically that valve ends up basically shutting all the way, refrigerant's not getting into the coil, it backs up, ends up causing a freeze up, and you will sit there and run that unit for ten hours and your temperature keeps going up and up and up. And then airflow stops going across that coil because it's starting to freeze up and it can't pull anything across it. Double edged sword. Yeah. So comes a big ice block in your house. You don't like that. No one likes that. You would think that it would cool your house, but it does not. No, it does not. So and that's what happens is, you know, if you if you're experiencing that, you know, it could be a realm of things. you know, the office gets a lot of calls all the time that, you know, hey, my unit's frozen up. You know what's going on with it. Well, it it's generally one of those items, right? Check your air filter first. Hey, it could be a refrigerant, it could be low on refrigerant or their metering device, and then you know, big issue like we talked about is airflow is could be the a a main cause of that that problem there. So when you guys are getting these new systems installed since they've been out let's say about a year now, make sure the airflow is correct, especially when they're getting installed. I mean that's the biggest thing. Otherwise you're gonna have a unit that prematurely fails on there. Secondly it's you don't want liquid back to that repr the the the compressor. So when those units start doing some of the stuff with airflow in that You end up getting liquid back to the compressor. Liquid doesn't compress, as we all know, and that compressor will end up prematurely dying and that sucks. So expensive. Expensive. So that's that that's that's that's a big one. So the other one, you know, I as homeowners I think want to know why, you know, you know, they had a unit, especially if they're, you know, they're older. They've had two or three units or they've lived in four or five houses. Older systems, their coils didn't leak. You know, if you get the comment now, why does my evaporator coil leak? You know? Well so take a deep breath. Yeah, it is we're gonna be here for a minute. so the old R twenty two, which is like the Lord's refrigerant, the best refrigerant out there. John's opinion. I I'm a little biased. it Your your standard pressures are about half of what your current refrigerant levels run at. So you're looking at a low side of about like seventy five to eighty PSI, high side of about like two eighty ish, three hundred, depending on a really hot day or not. And on this new stuff, the four fifty four B or heck, even the four ten, you're looking at four ten, right? Let's let's keep it simple for the homeowners. Keep it simple for the homeowners. That's what most homeowners have right now. We went from R twenty two. Yep. Most people aren't gonna know this, right? Yeah. We went from R twenty two to four ten A. And four ten A is when we started seeing leaking coils. Yep. And in four ten A we went from like seventy-five on the low side to 140 on the low side. So doubled. Yep. Doubled. And then on the high side, we went from let's just say 300 to like 450, 500 on the hot days. So all these pressures just Jacked way up. And the some folks back at like at the drawing table were like, hey, this coil can handle this pressure. Statistically should handle Yeah, but I mean, so you have three different metals. You have tin fins with copper tubes and steel end caps. So dissimilar metals with condensation and higher pressures equal lots of champagne or pinhole leaks. Usually right around year four to six. Somewhere right in there. Yeah. And but that's just because the they never redesigned the coil to actually take the extra pressure of the double depression. Yeah. Yeah. So and what basically Sean is saying here is, you know, so you had this R22, then we switched over to 410A, and you know, back in the day, most of these The copper tubing that was inside the coils was all copper at one point. Yep. Very heavy coils, you know, when you had to exchange them out, really heavy, right? So then after they switched them out, you know, they kept you know, went to four ten A, they went to different types of metals, which then there were certain metals that were starting corrosive. So they would get corroded. Well, to Sean's point, you doubled the pressures. Well, when you double the pressures, you start to develop these small, tiny pinhole leaks as you in the industry. And all guys in the field call them champagne leaks. So it's not like your refrigerant's just dumping out super fast out of this coil. Because it's just not, you know. So then you start to see your electric bill go up, you start to see basically your system's working longer. And then, you know, if you leave it too long, you start to see the unit freeze up because that's one of the issues that causes units to freeze up. Is it low on refrigerant? So yeah, that takes a while though. You got that. So then, you know. Wine back when we were doing this, a lot of these manufacturers ended up having lawsuits again against them because people bought brand new systems and there was leaks. They didn't make any changes on You know, they cur supposedly corrected it. So you take all the masterity of of of that. Not just one manufacturer, really. Almost every manufacturer had issues on it. Yep. Everybody had their turn of the chopping ball. Fast forward to the new R thirty two that we have. So we went from R twenty two to four ten A. Now we're at 454B and R thirty two. So let's take four fifty-four B. so the pressures are now even higher than four ten A. So we got even higher pressures going in now. And so, you know, that coil, right? So if there's any corrosive, you got this this heavy pressure in there. Yep. It's easy for these things to start leaking. I mean, across the board, Sean, I mean, I mean, all manufacturers were replacing the coils all the time. You know, I don't think there's a man there's not a manufacturer out there that I would say is safe against these coil leaks. no. We replace them all all the time. that's the it's kind of the I I hate to say it's the new norm, right? Like it's the new norm that it definitely feels like it. It definitely feels like 'cause we we probably do what at least four like four coils a week. I mean some weeks for some weeks we're doing you know, fifteen, twenty. Yeah well, yeah, on the on the super bad ones, yeah. Yeah. Usually right at the beginning of the season will is when people discover that they were all low. so we'll definitely do and they kinda peter out as the summer goes along. But I mean, yeah, we do a lot of coils. It's probably yeah, it's probably one of our our highest items that we repair. Yeah. Or replace, sorry. Yeah, and for homeowners, listen, I mean, replacing a coil is it's kind of a big deal, right? Like yeah, it's it's like takes two guys. Yep. Three, four hours of work. Yeah, we're you know, that we're crawling around in the attics for a good number of hours. Well, and the big thing too that the that that you know, so it depends on the manufacturer, but some of these manufacturers, which sucks for us, you know, is they had the four ten A coils and then they all started making four fifty four B. So the old coils when you did a coil replacement, you could just the same cabinet that fit Basically that coil went in and out of you could swap them out. But now some of these you gotta do a whole case change out. So, you know, it doesn't match up to the plenum, it doesn't match up all the way. They're usually like six inches longer. Yeah, so now you gotta redesign you gotta redesign it to make it work how it should. So that's been an issue. So basically, guys, I mean, as homeowners, I mean if you if you're a first time buyer of a house or you're new to a homeownership, I hate to say it, but yeah, you your coils are gonna probably leak at some point. You know, if you they don't leak, you're one of the lucky ones. that's just how it is. It's incredibly rare. Homeowners at you know, take, you know, even our office manager Jeff, you know, he's like, Man, I had a unit for seventeen years. It didn't develop a leak till like I think you're fifteen and, you know, he had he had a guy that would just charge it up and get by then me and you were actually the ones that replaced it later on with the four ten A system. But you know, you get all that that it just you As a homeowner it's like, Well, I had nothing I didn't have to do anything for fifteen years and now it's like you get homeowners that are moving in, they're like, My house is brand new, it's two years old, the coil's leaking and that just sucks, you know? It just it's so basically higher pressures, corrosion, the type of metal they're using now. I mean it's And nothing is made like it used to be anymore. Yeah, hands down nothing. I don't think anyone will yeah. And Yeah, you got these robots putting these coils together and I mean Mistakes happen. Yeah. They they do happen. You know, it's just I I hate to agree with you on this, but yeah, it it's kind of the new norm. And it just Yeah, like it's my big suggestion for anyone, right? Like as we have repairs coming up, like you know, just like anything else, you save for vacation. You almost need a little savings account now for repairs, right? It's not even just air conditioners. You know, you talk about toilets, you know, talk about water leaks in in in shower pans, like I was talking about talking to my flooring buddy, and he's just like, Man, dude, you know, these pans are always cracking. So it's not it's not just even H HVAC side. So the biggest thing is I would just like, you know, your vacation fund or anything like that, I would start saving money to just, you know, when repairs happen, 'cause they are gonna happen. It's not if you're in a house and you're gonna be in a house for five years, ten years, you are gonna have repairs. I mean, things are gonna come up, you know, even on the water treatment, you know. Air conditioning, washers and dryers, you know, refrigerators, that all at some point is gonna fail or need a repair. So Yeah, one hundred percent. The other big item that you know that we see a lot too, I s w it wasn't as I think a big deal until about, I don't know, four or five years ago, but we're starting to see a lot more blower motors go bad. yeah. Sean, do you wanna what what has changed in blower motors for homeowners listening? Blower motor is is the device that's basically Pulling air through your return, moving it through the unit and putting it back out to supply vents. I know, you know, I'll let you explain it a little bit, but what happened to blower motors? There's been some change, you know, because they want them more efficient. Yeah. But when they kind of when we went to these more efficient motors, we've now seen a lot more failures with them. yeah, 100%. So your old style blower motors just had one, maybe two speeds. And then you had a you know, a capacitor that would let it turn on and off or help it turn on and off, kinda like a little battery pack. And then once then when it starts, it just runs and you get what you get. It puts out X amount of air. Now that, you know, Big Brothers stepped in and basically mandated efficiency ratings. Which is good. Yeah, it it is one hundred percent. 'Cause we d we need to be more energy energy conscious about like 'cause I mean We spend a ton of money on power bills anyway. So we need to, you know, try and get that down where we can. So the new design is called an ECM or a variable speed blower motor. And it has it basically the unit is told by a little brain on the back of it. It's a computer board. it tells the blower how fast to run. So the problem that we're running into now is we have a a computer chip, a plastic brain telling this motor to to go. And as we all know, plastic parts and computer chips, when they get hot or they start you seeing a lot of use, they conk out. So and then power issues that have been going around a lot of a lot of manufacturers. Yeah, hold it real fast. So yeah, but basically it was a PSE motor. Yeah. Single speed. Single speed. Ran at one one power. You know, those old motors you'd see them They're tanks. You'd see dirt, nastiness all over them. Yeah. You know, sometimes they got so much dirt on them. We've both have seen fires started from So but these new motors, these as Sean said, they're in they call them ECM motors. You know, we'll keep it very simple here, but they're ECMs that have that computer brain on the back. Yep. Well, let's go back real fast. Airflow can affect these things. Yes. Airflow's huge on these on these things because of, you know, static pressures, which static pressures on these things. These motors. And they're higher horsepower motors too. Yeah. So yeah, you went from a lot of these you went from a three quarter, half horse, three quarter to a full horsepower now, you know, that we're seeing a lot on these motors. Yep. So they have these brains. So basically you got a computer brain on the back. If it gets hot, it's overworking and it and basically, you know, the the airflow sucks on it, air filters dirty. That's another issue. It can cause these motors to clank out and everything else. Well, generally You know, the motor itself is fine because the motor itself is still kind of that old type motor, right? Still still has windings in it, still has the shaft. It's the computer brain. Generally it's the module on the back that goes on there. So that's generally what ends up failing on that that issue. And then we'll get into what Sean was about to talk about is power issues, right? It's here with utility companies, we are starting to see more in our area of power surges and issues. Blockouts, brownouts, and When you have a you have this motor on, and it doesn't matter if you guys are buying, you know, this I'll stop for a minute. If you guys are buying even single s you know, stage equipment, two stage equipment, or multi stage and variable, most manufacturers now have ECM on almost every piece of equipment has an ECM motor on it. So you'll hear in the comments a lot, it's so funny that what we read people are like, you know, variable speed and all this, it sucks. There's no more problems. the the repairs cost more. No, it doesn't cost more because it's under warranty for one. So the parts covered. And, you know, if they're registered, it's got a tenure part. Depending on what labor plan you got, it is going to be partially covered or fully covered, you know, depending on what contractor you go with. Right. So yeah, I mean you get this you buy a single stage equipment, you still have an ECM motor, and ECM motors are not cheap. No. So they're expensive. So they're proud of those motors. Manufacturers are very proud, you know. We'll see that part. you'll see them either range from four hundred dollars to sixteen hundred dollars for that an ECM motor at our cost. So it's like you're like makes us cry. Yeah, you're like, wow, that you know, it's it is expensive. So that is that's the issue. So, you know, you talk about these issues here where you get power surges on here. Well, that surge can come in and you know, basically short circuit that module on the back. Well That sucks 'cause now you're out that luckily manufacturers, you know, we submit the warranty claim. If it's under warranty, you'll get a motor. You'll have to pay the labor if you don't have a labor, which most people that are moving to new houses don't don't have it. They have the two year workmanship warranty. And that's it. That's it. So it's that that's that's that's the crappy part. So that's I mean, that's one of the the issues we're seeing here. So your E C motors, that's a I mean I mean all parts are are getting hit. Yeah, I mean we we've seen to the point where it's taken out boards and blowers at the same time. that's kind of rare though. Usually it just takes out the ECM and you know, we're pretty Yeah, that that that it is what it is, but what what what can what can a homeowner do at home to protect their new ECM motor? surge protectors are good. So not just like I wish it was one that you could just go to the Hardware store and you know, kind of like plug it into, but unfortunately, this is one that has to be wired directly into the unit that will help mitigate it. It doesn't solve the problem entirely. Nothing's a hundred percent prevent. Right. Yeah, nothing's a hundred percent guaranteed, but it will increase your chances. Yeah. so search protectors are good. I mean, heck, even if you want to do like a whole home search protector, that would be better than nothing. Yeah, yeah. But one right of the unit is gives you the best shot of. It's surviving especially how expensive equipment is nowadays. Like if you have a system that's older, eight, ten years old, and you're trying to get the fifteen, seventeen years out of it. Because those surge protectors, the nice thing about them is is you can put on the new system, right? Like if it's only a couple years old and it you know, you can move that that onto the new equipment. We just did we just did that yesterday when we did we were doing an install and they they had a electri electrician that recommended search protectors on all that and I was just like, hey, well, you know, we'll make sure we put that on your on your new equipment. Yeah. So took it off the old disconnect, put it in the new one and Yeah. Make sure we make sure we test them and they're good to go. So though if you guys want to try to prevent those, I mean, if you want to try to save your blower motor, we'll we'll recap on this real fast. Change the air filter. Make sure duct flow is good. So if you're getting, you know, make sure you get a tune up, ask the technician to make sure your duct work is good. The hard part is if the most technicians don't know ductwork, that's I hate to say it, but you know, everyone's dying art well, it's just an opinion. Everyone's got an opinion versus what actually the manufacturer suggests, you know. Yeah. on there. And, you know, and then there is no code that says ductwork has to be a certain way. I just moved in my new house and all you know, this is funny, just for we'll we'll stay on this real fast. You know, but I didn't ha they they f they they put the returns directly into the unit and didn't put plumms on and you know the contract I put in was like, well, it doesn't say they have to be that. And I went to the builder and I said, I don't really care, but I said there's there's there's doing it that way and then there's doing the right way and making sure my system's gonna last long. Because if you guys don't have the airflow corrected, it's my systems are gonna work harder, everything else. so that's like And I have ECM motors and all and all those equipment. So it's like yeah, it's you know. Yeah, you if you make a unit work harder, it's gonna die sooner. It's like what's gonna last longer? A Toyota Corolla driving down the road doing stop and go traffic or a race car. Which one blows up first? Yeah. Race car. Yeah, so that's it. the other thing is is we're starting to see it is interesting, July, August, we start to replace a lot of compressors. yeah. So what causes compressors to fail? You know, just keep it very simple because once again, for homeowners. Yeah. I don't really care about some HVAC tech that has his own opinion. Keep it to himself. Yeah, yeah. You can just kidding. so compressor failures. especially right now. so really there there's kind of two things. we're kind of touching in on the storms a little bit that are coming through. look Those cause power outages, electrical spikes, all sorts of stuff. Compressors are an electrical motor and they do take hits from that kind of stuff. So what let's do this? So when they when when a surge happens, yes. Inside that motor, it gets hot as crap. And electrical motors and heat. So yeah, they're not yeah. So when those surges come through, it it literally we have seen it over and over again. It Overheat your compressor, then the office gets overwhelmed with calls because they're like, My AC is not coming on. Just shut it off, let it cool off. Go shut go shut the breaker off for about 15 minutes and kick it back on, you know, maybe 30 minutes later or whatever. Just and everything comes back. Everything most of the time, 80% will come back online. Yes. But it is funny because that once again, it so if you think about that, when that surge hits that thing. It overheats your, you know, so you drops a leg of power. Now the motor starts. That is lot of of of power to overheat overheat a system that's not even running at the moment. A lot of amps. Yeah. So so there's storms, which we know what that causes. the other thing that again, because the storms bring it, is humidity. the humidity, while won't kill a compressor all by itself, it basically it makes the systems work a lot harder. Lo they they they run for longer. They You know, so you all of a sudden now your usage time is going way up. And again, going back to the race car versus the the family car, which is gonna die first, the one that works hard or the one that's kinda, you know, got a nice easy life. Yeah, I I mean compressors die a lot because of that. And, well, airflow. Airflow. Go back to airflow. We go back to airflow. Airflow does kill compressors. So it it's the it's usually The I I'd say the two biggest things that that cause them are are your storms that come through and then just the extra workload that the humidity that the storms are bringing that the AC units are now having to remove. So you'll definitely know when the humidity is in the air, A, you can fill it naturally when you go outside. But then you go look at your condensation drain and that thing is just I mean It's a waterfall. You can put a five gallon bucket under that under that thing and you are gonna fill that thing up very fast. Yeah, like thirty minutes. Very, very quick. So it's like, you know, that's why I mean those systems are pulling out all that humidity out. So they're working overtime. one hundred percent. So this like thirty percent more work or something like that that they have to do. So during that time of the year, guys, i A if your duck works crap, I mean, as a homeowner it's gonna be hard for you to know that because once again, there's no code. It's it's all really up to the contractor to make sure it's installed correctly. Yeah. On there. but like the biggest thing you can do is make sure you just Every even you know, I say every thirty, forty five days, but during monsoon season, I mean it's Check it every two weeks. Every you know at least check it. Every two weeks, you know. We were at that call in Gold Canyon where Yeah. That compressed the un the unit's three or four years old, it's it that unit's gonna fail, you know, more often. Because it it's you know, the unit's a three ton it was a three ton unit. Yeah. Yeah, with a ten inch duct. It's a ten inch duct, so it's just like that unit was not breathing. It's like trying to run a marathon breathing through a straw. Yeah, it's just like it wasn't gonna happen. And that but that was the contractor that put it in. I mean, it just didn't have the right size return, everything else like that, you know. The installs that we did yesterday, we I think we upsized both returns on those. So Yep. And we we ran a new one. Yeah, to today where I know we're running. I know today we have a job that we're running extra return to make sure that thing's working correctly because it didn't have enough return on it. it is funny because you'll see these pictures of people saying, Hey, I'm gonna save you money and then you see their install pictures and you're like, That return's too small, that return's too small, that return's too much. So how you reused the old plenums or didn't use a plenum at all. Yeah. Like what are you like, are you really saving them money? You're saving money up front by giving the expensive cheap option. Yeah. But In the long run, it's it's a losing game. It is it it it is it's it's a losing game 'cause it's like if well, I'm glad you saved me two grand up front, but y you really cost me five grand down the road because you forgot to register. Well Yeah, more more like fifteen grand because you gotta replace the unit way earlier than you're supposed to. Yeah. And that's the thing. That's I it just it's just these these equipments are they're not as built as tough as they were, like Sean said. So that's that's just They they you gotta be a little nicer to them nowadays. You really do. You kinda have to baby almost, which is funny. Yeah. and then, you know, what else, you know, can you know, we see contactors, which are basically a relay switch. Yeah. What causes those to fail? lack of maintenance is really kind of the death of those things because so basically a contactor, if you don't know, is the unit the thermostat, we'll just say. tells the unit to turn on and that is a little contact switch that closes and it allows power to go to the compressor and the fan motor and boom you got your cold air. Well you got your cooling anyway. So every time that closes, it's two machine metal surfaces that come into contact with each other that electricity now goes through. Well if you get dirt on those contact surfaces, well now you've got an imperfect mating surface and it starts arcing out. And once it starts arcing out, it it's only a matter of time until it dies all the way. so really proper maintenance, you you'll see guys get in there with either like a blower or like a brush and either blow out or brush them out to make sure that they it's inevitable it's gonna happen. you can't you can never keep a hundred percent clean all the time. Unless you're out there before every time it starts up, you clean off, which yeah. Who does that? Yeah. so but that'll just help that contactor last that much longer. is just keeping those contacts as clean as possible. but really that's the con if the contactor switch is is is failing and it and the contacts aren't making good connection, it's just like any wire, right? If the wire on your breaker is loose and it's not getting good connection. Heat. That little simple part, what can that part cause to the unit? What can it break on the unit? Because it is n it is it's it's starting to fail because we see it a lot where that just gets skipped, right? People are like yeah. It's starting to pit. It's doing its job because it's allowing everything to turn on and off. But the way I see it, it's always like a the way when I was out in the field and you know, it it is like a small cavity, right? It's like, well, my tooth isn't hurting now, it's not doing anything. Well, we can just leave it. Well, the problem is if you don't take care of something like that and and the pitting gets worse and worse and worse and it ends up taking out a fan motor, a compressor, any of that stuff, and you're like, Well, that sucks. Now I could have got a couple hundred you I could have replaced that switch for a few hundred bucks and now I'm thousands of dollars because I didn't re take care of it now. Yep. you know, that that always sucks. And we've seen, let's see, we've seen wires melt off of those. We've seen contactors get stuck. Yeah. And never shut the unit the unit doesn't shut off. So then now we have a compressor that's just running twenty four hours straight. Before and hopefully the homeowner notices it yeah quickly, but never never happens. the funnest one I had was they let it run for seven days. A week. It let it run for a week before they noticed it. Sha Sean had one my I I I you know that this was I don't know, nine, ten years ago when I I recommended replacing the capacitor contactor because and the wires were starting to yeah. Mm-hmm. And I was like, this needs to be done ASAP. Showed videos, so pictures, documentation of it. So they said no. Two days later, everything, you know, got too hot and the wires melted and it melted all everything in the cabinet. because these things were you know it was over you were taking to basically you were drawing too much power. These things were overworking. And you know, we have seen it over and over again where I mean, you end up causing an arc of fire, which is just not good. no, fire fire bad. No, no, it's just not. I mean, just I I remember working on one of the blower motor. I remember I opened the door and I literally had to video, you watched it, go psh, psh just like just arguing. Just I I I had to shut the unit off and I was like, I you can't run this thing 'cause I you know, now that I've seen it, I'm not gonna I'll never forget the the one that I heard chirping. Like it was I was like, why is there a bird in here? See, there's a bird in there. It was like it was like chirping. I was like, what is that? And then I looked at it, and sure enough, you could see little arcs, and every time it would do that, it would chirp. And I was like, crap. That's not good. No, not good at all. You're like, that one that one had melted a lot of stuff. Wire nuts going into it to the main line. it was bad. That was Yeah, it's just like I mean these we we overuse these systems in our region. I mean they I mean we don't use our heaters that much. I mean furnaces, you know, in other regions everyone's like, the furnace goes bad. Furnaces I mean, for me I don't kick mine on that much. I kick it on early in the mornings, sometimes in the winter. Yeah. Last couple winters in Arizona have not been cold. I mean we've finally gotten some rain here in monsoons here, which has been exciting. That's been fun. But kinda, you know, do recap of what we talked about. You know, if your unit is freezing up, airflow, which is, you know big it's basically refrigerant, airflow, air filters, that's you know, there. Blower motors that we're seeing a lot of. It's you know, switched over to these ECM motors. So, you know, these ECM motors can have surges, static pressure, which is airflow and all that, you know, ish issues there on there. Compressors, once again, airflow surges. Another big one, go back to the surges, you know, that's that's a big so so basically what I'm hearing is airflow or poor airflow kills everything in your unit. Airflow is the death of ACs. It is the death of them. Yeah, poor airflow. Well, it's just like me and you've talked about this so many times that I wish somehow Arizona Or anywhere. I don't it's the southwest. Just anything like why can't we have more specific codes for air conditioning systems in the sense of like Yeah, it says you have to if you have a five ton, you have to run a minimum of a 20 inch duct. You gotta have twenty inch. Five tons have we've seen sixteens on sixteen, eighteen inch ducts, you know. I mean eight yeah. Every unit should have a plenum on it, you know. 100%. Like I get, you know, room can be an issue in an attic. So yes, sometimes you're limited to that, but like There's always ways around it. You know, where we've had a run custom plenums. Where we've had done custom plenums, you run up wise, like or or when the houses are being designed, yeah, the architects put in wild thought. I know this is crazy. The architects put in enough space for everyone to have plenty of room. But I realize that messes up the aesthetics of the house sometimes. So my bad. Yeah. Suggesting that. Yeah, but like I want aesthetics, but I also want to be comfortable in my house. I mean, but they don't care about but and I and it's not their house. And I want lower electric bills, right? So it's like Yeah. As these utility companies are raising all their prices and everything else because you know, more people are moving in here and it's, you know, powers get more expensive. You know, I would like my AC to run as efficient as it can. but that would be sweet, right? I mean, it's just like I just wish there was there was more mandated codes around air conditioning systems because it would honestly help the industry a lot because it would almost standardize it because y you have so many people That have an opinion that say, Hey, by the way, well, I think it should be done this way or this way or this way. Well, I I I I appreciate your opinion. I have an opinion. Sean's got an opinion. But yeah, at the end of the day, the manufacturer wants it this way, you know, but once again, the code says, Well, it doesn't matter. There is no code. You just put duck fare up there. You know, and you just as long as it's got a duct, it's happy. My my project manager is like I was like, hey, this is wrong, this is wrong. He's like, I don't know, there's a vent there. I mean, that would like he he's a very smart guy, like, right? So like he know but like once again, most people look at air conditioning like, I as long as there's a vent there and it blows out cold air, it's working, right? Like that's not how it works. It should be you know, we should there should be mandates for like balancing air because how many houses are we going into where they have hot rooms? Very hot rooms. And the and the and that hot room is always the last one. Well, their excuse to me because I had a couple rooms that weren't cooling, they're like, Well, the engineers designed it. And I'm like, Okay. Well, the engineer ain't living here. Well, and I'm fine with the engineer designing it. But the guys in the field, did they d did they install it like the engineer wanted? I know it's a new house, but it's like That's the million dollar question. Once again, it's like playing a game of telephone. It's like, hey, we told them to do it this way, then they told them to do it this way, they told them to do this way, and because how often have we gone and done something out in the field? Because it's like, yeah, it'll be easier if I just go this way. Yeah. Just because easier doesn't mean that it's the right way. Yeah, that's the thing. So guys, if you want to save your air your AC unit, airflow is the biggest issue. Issue, issue, issue, issue, issue, issue, issue. I think the only thing airflow doesn't contribute towards is the condensate drain. Yes it does. yeah. 'Cause you're not changing your filters, it gets on the coil and then it goes into the drain and clogs it up. My bad. I tried. He tried. I got shot down. Like no. I got shot down. Yeah. Yeah. Bam, Sean, you shot down right there, dude. Yeah. I mean I yeah. Why do refrigerants change? So we had R twenty two. Yeah, R twenty two. R twenty two best refrigerant ever. So we we all loved R22. I mean, it was just for how well the houses felt great. then we had 410A. 410A, honestly, I thought was all right. It was pretty good refrigerant. I'm just gonna be this new stuff, 454B and R thirty-two. you you have all these new sensors that are required, you know, A2L sensors, RDS sensors, whatever you want to. We've already had like a handful of fail. Because it got a little wet. It's what's interesting is the other day we didn't install this equipment, but we replaced a coil that had been leaking and there was an A two L sensor and you know, that was in the system. The system didn't shut off. So it didn't connect, you know. Didn't detect it. Didn't detect the leak. But it's like we've gone to this new refrigerant, and it has all these extra sensors on it. The units in my opinion. You know, they they a little more vibration now out of these new units because the pressures are higher. yeah. but you know, they they keep switching, you know, because it's better the refrigerants are getting better for the environment, which is which is good. I'm I'm I'm good with that. But it is, I mean, the hard part, and now it's like we now have manufacturers that have, you know, taken, you know, either they we have manufacturers using four fifty four B We have, you know, manufacturers that are using R thirty two. yeah. Yeah. Yeah. You know, I saw like I was reading some posts the other day. We don't we use I mean, rare that we we use R thirty two of the the stuff that we sell, we use a lot of four most of our equipment, I would say ninety eight percent is four fifty four B. Yeah. Yeah. I was reading some things through this page. This one contractor was talking about when it gets over a hundred and ten, all their R thirty two systems haven't done well in in that in that environment. I mean us as a company I don't we haven't experienced that with four fifty four. Not really. so the homeowner, right? I mean, basically you you've gone through these switches, so there's always gonna be some kinks. Even when we went to four ten A, that's where we saw the coil leaks that we talked earlier. yeah. We saw a lot of coil leaks. Coil leaks ever since that started with four ten A. We have Well and then the compressor chatter too, 'cause they swapped the compressor designs for four ten. Yeah. So we've we saw we've seen some kinks, you know. I think four ten A started getting worked out. It actually started being really good. Yeah. So we've worked over to this new stuff. Once again, there's gonna be kinks have to be worked out of this. It's it's like I know anything different, you know, there's there's gonna be some issues, there's gonna be some trial and error with everything. I mean just because the engineers say in the field that, hey, by the way, four ten A is gonna work in the R twenty two coils does not mean you know that it actually everything's gonna be everything's gonna be s working handy and great, perfect, like it should out in the field with the new stuff. But once again, I mean Well, we talked about it, we'll go back to it. Airflow, it all these manufacturers are s just saying airflow, airflow, airflow, airflow. So when you are getting these new systems installed, make sure the airflow is getting done correctly because that is the biggest hype that we and all the trainings that we're getting and the classes we've taken and everything else on this new stuff, everyone talks about airflow. So change change air filters and then make sure the ductwork and plenums and system is sized correctly. Especially in an older home. 'Cause the older homes with the R twenty two, R twenty two was very forgiving. but rarely, unless you know you have a fairly stand up company, will that company upsize to the newer ductwork or like to the pr appropriate size ductwork. So you might have R twenty two ductwork for a four fifty four B or R thirty two refrigerant system now, and like you have to have the the ductwork right or it will not work. Yeah. So at least not well. No, it won't. So to wrap up, make sure you guys are basically doing AC tune ups on your unit, picking a qualified contractor, making sure airflow is done correctly. The biggest change of filters. Yeah, filters, change of filters. Filters. once again, Sally always wants us be make make fun of us and she always has some guessing game for us. So I guess so earlier she gave us a object in it that's in the office, which office could be the warehouse in the back door up here. Yep. I know mine. I know mine. I don't know yours. So we both gotta ask some questions. We'll both, you know, we'll do one at a time. So Okay, one question like you asked. No, I'm gonna ask you until I get yours right. You're gonna ask me until you get mine right. So I got, you know, or so Okay, let's go. Let's we got this. Is yours on a desk? It can be. Is it a person? No. Okay. It can be. does it get does it stay on the desk most of the time? Stay in the desk? On the desk. No. No, no. Well, I mean, no. We'll just say no. It's it's one of those weird ones. You'll know once you're I get it. It's always weird. Yeah. When it's here, yes. It's usually on a Okay. Is it is it an energy drink? Is it an energy drink? Yes, it is. Bam. I knew it because Richard always leaves to but but which energy drink? my. Which energy drink? An Alani. No. A bloom? No. Monster. Yes. Boom. A monster energy drink. Boom. Got it. Okay. Lock loaded. Now, yours. Yep. I gotta guess yours. Yep. boy. Let's go. Does it belong? well we'll we'll just repeat some of the same questions you had. Does it belong on a do you usually find it on a desk? No. No, you don't find it on a desk. Is it does it have wheels? No. Is it in the office? Yes. Not the warehouse? Not the warehouse. Well, I mean it can be in the warehouse. But it's usually in the office. yeah. Is it in your office? It can be. It can be? Is it right now? No, it's not right now. Not in the off not in my office right now. Can be it's it's in an office, doesn't have wheels. This is cruel. This is cruel. Obviously you can't drink it. I highly doubt she'd give us a bulk of an energy drink. No, she didn't. It's not an energy drink, I'll say that. Man, I don't know what else that We're doing so what's that? I know. I know. Usually I just feed off this guy. and you're way better at this than I am anyway. I don't know, you're pretty good earlier when we do you know. All right, come on, let's go. is it electronic? No. Not electronic. No. Do you sit in it? No. No. I'm gonna say I'm gonna say no. I'm gonna say no. Is it Jeff's cart? It's not Jeff's cart. I've sat in Jeff's cart and I almost broke his cart. I almost broke his cart during a giveaway thing that we're doing and he looked at me and was seriously, Rossi? I'm like, my bad. So you say no you can't you don't you're not supposed to sit in it is basically what you're I mean you could but you're not supposed to. It's not like the bucket trash can you wouldn't sit on it. You wouldn't sit on it at all. Sit on. I think yeah. Come on, keep asking. What's keep asking? Although it's not electronic. It's not trash is it a trash can? I don't know. Not a trash can. Not a trash can. No. Does someone use it every day? You know I'm gonna s I'm gonna say, you know, 'cause I kinda did this with with one of the guys earlier, Signal. I'm gonna say no, because that it it does confuse people when you say that. No, you don't use it ever. it's in the office right now. It's in the office right now. It's in the office right now. Like this office right here. Not my office, but it's in the office. It's in the office. It's a printer. It's not a printer. I'm just gonna start listing stuff off. Jeff's golf clubs. No. I'll help you out. It was close. What's that? Your last question or your last Jeff's golf clubs? I'm gonna say it was close. Is it a specific club? No, not it's not it's not it's not the clubs? No. It's not his golf bag. No. It's in his desk though. Is it his tree that he's got in there? No, it's not his tree. Sitting right next to him. I'm trying to help you out. It's not that's that wasn't a very good hint. I'm really bad at this game. Let me help you out. Let me let me try to I'm trying to help you out a little bit. I kinda made a comment about energy drinks about this earlier. Huh? I made a comment about energy drinks earlier to this person. Sally? Is that a pretty good hint? I mean that's I think it's a pretty good hint. I said something earlier when you guys were all here. It's not so I know it's not sa I know it's not you. It's not a person. Or is it a person? It is a person. Is it Jeff? It's Jeff. It Jeff. Bam. Ding ding ding ding ding. I didn't realize that Jeff was an object in the office. I'm gonna have to make sure I tell you what Sally thinks of. Yeah, don't that's I said on Jeff. The funny thing is, yeah, Jeff Jeff is very anti touchy, so yeah, so don't he's like a little bit of a dermaphobe. No, I tried to do my best with that, so Well, hey guys, thanks again for listening to the podcast. Hey guys, if you guys are looking for a contractor in Arizona, you know, or have need a suggestion, you know, give us a call. We'll t get you taken care of. We have a great crew here. We are locally proudly owned here in Arizona. So if you guys are looking at options on new air conditioning systems, we'll get you guys taken care of. We we always normally beat a lot of these big corporate companies that are out there, that, you know, are run by these corporate giants, you know. So if you guys are looking for an honest company that's family owned, that is not backed by Wall Street or some corporate people and want to be taken care of. we are all a very tight knit group here. and we'll all get you taken care of. You guys can request Sean, he's a great guy. He's been Sean has been with me since basically we have started Rusty's air conditioning heating from the get go. We have grown into now about fifteen employees here at Rusty's. So we look forward to taking you care of you guys. If you guys are in Arizona, give us a shout out on social media. Sally's always on there posting videos of us doing funny, silly things on there. What are you talking about? That's just that's just the job. That's just the job description on there. And then check out we are always doing our giveaways. So if you guys want to get entered on those giveaways, Sally will announce those every two weeks. So that is pretty cool. Those have changed from you know gift cards to a full stay vacation, car detailing. She's always pushing me to move up the the needle there. So if you guys are looking to get something really cool. Check us out on social. Give us a shout out. And hey, let's rock, let's roll. We'll see you guys this summer. Peace out.