I’ve written before about unresolved questions surrounding mRNA vaccine manufacturing and regulatory oversight, particularly where transparency and enforcement appear thinner than the public was led to believe. This presentation revisits one of the most technical - and most consequential - of those issues: residual DNA contamination and how regulators defined, justified, and ultimately enforced safety limits. Kevin McKernan walks through what the standards actually say, how they evolved, and why the commonly cited “10ng limit” may offer far less assurance than advertised. Regardless of where you land on the policy implications, the underlying documentation and process are worth understanding - especially given how confidently the issue was dismissed for years. Watch with a critical eye, and compare it to what we were told at the time. Get full access to Rational Ground by Justin Hart at www.rationalground.com/subscribe
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Transcript
From the show. Tap a time to play from there.
SPEAKER_00Good morning everyone. It's January 11th and I've just realized online that some folks are not fully understanding what's going on in process one and process two and how the DNA contamination story folds into this. And so I wanted to spend a little bit more time here really highlighting those differences because when you see what went on in that shift, you'll understand the deception that's going on and you'll also come to recognize that this was a premeditated move. You can tell what their intentions are by what assays they built,
and you can see by what they did that their plan from the start was to always use
SPEAKER_00process two. It was not a, oh, no, we can't scale up. We have to rip the PCR and bead cleanup out of this process to scale, and we're just going to switch to process two now after the trial is complete. The assays they had in place during process one only made sense if process two was ultimately to be considered and used which means they set the trial up in process one intentionally that way when they knew they
would be on process two in the end all right so you can this is evident by the assays that they designed and they gave to the regulators and in both cases for process one and process two the assays that they designed were designed not to find
SPEAKER_00things all right So I want to make it a little bit more clear because my presentations in the past doesn't seem like that really came out. Now, before we get into this, there is another detail that I feel I've missed in speaking about this in the past. I've just gone over it too quickly, too many slides, that kind of thing. So I'm going to zero in on a few issues about the 10 nanogram limit that people don't fully appreciate. And then we're going to talk about the different assays that they have for monitoring the DNA and the RNA in process 1 and process 2,
and how those can only make sense if they had planned to do process 2 from the
SPEAKER_00start, which makes you question, why did they run process 1 the way they did? They did that to cook the books, knowing they'd ultimately be in process two. And you'll see this. It'll become very clear to you that they, from the get-go, their plan was to use process two. They just came up with a trial that would bend this. And the evidence is in what they target in PCR. So, okay, let's hit on the 10-anagram limit a little bit.
SPEAKER_00Okay. This is a limited hangout, okay? 10-minute half-life of DNA is what happens when it's naked. We all know this, right? And so they come up with these limits based on naked DNA injection. We get into the world of LMPs and everything goes out the window because LMPs protect the DNA from the degradation process, so we don't know the half-life of the DNA now. And we're learning this real time in patients as we find patients that are expressing spike 1500 days later. Okay,
this is a bit shocking that the pharmacodynamics and pharmacokinetics of this drug
SPEAKER_00were just a crapshoot. And we're living with this experiment now real time on patients, unfortunately. Now, you have to understand how did they come to this 10 nanogram limit? Okay, like what is the origin of it in order for you to understand its context? So it comes back to this Sheng Fowler and Keith Pedden paper where they were taking genomic DNA and putting it on cell lines or mice to try to see what the negative
SPEAKER_00effects would be, okay? And what most people haven't captured out of this paper is that the authors, rightly point out that the nanogram weight is not the issue. In fact, back when this paper was published, they were talking about picograms, and they've since loosened those regulations since they got liability protection. So it used to be 10 or 100 picograms, and now it's 10 nanograms. But what people have missed in this guidance is that weight
isn't the right metric
SPEAKER_00for a contamination like this. It's molecules. Weight doesn't give you the number of molecules unless you know the length. DNA. So for instance, human DNA at 10 nanograms is about 1,450 copies of DNA. That means the chromosomes are usually 100, 200 million megabases in size, and so they only have ends on the telomeres. The reason people care about copy number is that when you get down to 10 nanograms
SPEAKER_00of 200 bases of DNA, you're dealing with 50 billion copies, not 1400, okay? And it is the actual copy number that matters most because the copy number dictates how many ends of the DNA that you have. The ends of the DNA are what can be joined in integration. The ends of the DNA have phosphates and hydroxyls, which are the active groups that can be integrated and that ligases use to put DNA into integration events. So you'll note in Keith's work
SPEAKER_00that they point out here that, well, if this were a very small piece of DNA, like a retroviral DNA, which would be like the size of a plasmid, the DNA limit would need to be 10 fentagrams or lower. And if there are 100 copies of the infectious viral genome, the amount of DNA would need to be 100 adagrams, okay? What this statement is talking about is the molarity of DNA, and that's what matters, the copy number, not the weight, all right? Now, you may not be familiar with adagrams and fentagrams. But this is what helps you convert those numbers, okay?
SPEAKER_00So nanograms and femtograms, it's about 100 million fold. If you get down to 100 atagrams, as he was suggesting, it's eight logs lower than 10 nanograms, all right? This is why this 10 nanogram thing is a mirage. It's a limited hangout because everyone's talking about weight when the real number that Keith Pettin was speaking about in his guidance for this was about copy number, not about weight. And since then, people have always assumed that, well, all the cell substrate DNA that might contaminate a vaccine is whole genomes.
SPEAKER_00It should be 3 billion bases long, and it's gonna mean that 10 nanograms equals 1,400 copies, no big deal. But when you get down to things that are 5,000 letters long, not 6 billion letters long, that copy number suddenly goes through the roof. And so this is why he has a molarity-based recommendation in the paper that gets just ignored by everybody. All right, so when you get into the adagram range, and you're using lip nanoparticles, which make that DNA 100-fold more potent,
you can see that we're well over any rational limit that relates to the paper that
SPEAKER_00originated that 10 nanogram limit. And that 10 nanogram limit never really considered the LNPs making this last longer and be more potent. So that's the context you need to view the DNA contamination story with, because if you're viewing it in this context, we have a DNA contaminant here that isn't substrate genomic DNA. This is actually plasmids that are like viruses. They're very small, self-replicating molecules, and so you have to view them through the adagram guidance that Keith Padden put
SPEAKER_00into his paper. No one's doing that. So this means it's really important for us to look at how are they measuring this DNA, and the methods that they have for measuring this DNA, are they ever going to find it? And that is where you can see the deception that's occurred. OK, I've got papers here that show that Lim et al. describes high integration rates. You can see down there, it's like 10% to 20% of the cells are getting integrated when you put in transfection reagents. And this goes through some of the math about the molarity and
how it is those ends
SPEAKER_00of DNA that matter. And anyone who's done a DNA ligation reaction knows this. You can see it in Moniottis' manuscripts. And there's guidance on this where the ligation that you perform never asks you about the nanograms as input. They talk about the number of ends that you have, phosphates and hydroxyls in the molecules. So what is the molarity of the DNA? That dictates how many adapters you try to ligate. They don't go with nanograms because nanograms are a meaningless number if you don't know the size of the DNA.
And so the ligation conditions completely change if you're trying to ligate
SPEAKER_00adapters to 10 kb pieces of DNA versus 100 base pair pieces of DNA. Because the molarity is off by thousandfold. Or hundredfold, whatever it is. But it's the molarity that matters. Okay, so... Bancel knows this. I think you've seen this. Of course, this stuff can integrate. So everyone knows how we got here. BMJ talks about process one to process two and RETSF and Josh's work,
SPEAKER_00okay, and how there was no trial really done. A trial was done, but they never released the data because I think the trial data showed that this was actually extraordinarily dangerous. And so they hid that data knowing that the train had left the station. OK, so to understand the deception that's going on, you have to understand what DNA was in process one versus what DNA was in process two. And then you can see how they played this game of hide the ball. This is the plasmids that they disclosed on the right. This is the plasma we found on the left. And everyone knows they admitted this SV40 thing.
But I think I want to draw a lot of attention to right now is this can gene. This is what the can gene on the left there was disclosed by the TGA as being what
SPEAKER_00they target to monitor the DNA. And the reason why that's important is that when they were operating in process one, that target wasn't there. Process one, if you recall, amplified spike, which is from noon to six o'clock on the right side of this plasmid. They amplified that as a spike sequence. So when you amplify, that becomes like a thousand to a million times higher in copy number than the can
SPEAKER_00gene, all right? So post-amplified PCR, they then go and look for residual DNA of the non-amplified part of the plasmid. So this is what's happening. You have an input of a very small amount of this template plasmid. You run it through PCR, and you get millions of copies of spike. And then where does Pfizer tell them to go look for the contaminating DNA? Over in CAN. What are they going to find? They're going to find nothing.
SPEAKER_00This is what they should be measuring. They should be measuring spike. So why does a TGA, when they're FOIA'd and asked, what are you using to monitor the residual DNA, why do we get documents back from them that say this? Can gene. They've been given a target that doesn't exist. Now, this target makes sense if you're gonna run that plasmid through a coli. Because in that case,
the CAN gene needs to exist in order for a coli to copy it.
SPEAKER_00It's the resistance gene. And it should be there at equal copy number. We have a paper coming out that's going to show you why it's not really at equal copy number. It's actually at 1% of the spike for some reasons I'll get into in just a minute. But this shows you that A, in process 1 during the clinical trial, they gave them a decoy target to monitor the residual DNA. They didn't look at spike, which is the thing that they amplified as the input to the IBT reaction. They told them to look at the precursor to this process,
SPEAKER_00which would find nothing or very low amounts. Okay, so that's one thing. Two, this shows you that they probably from the start were intending... to go through process two by measuring the can gene, because that should be there. That's the one gene that, if the E. coli were to grow the plasmid, the only thing that you could really anchor onto, or that you should anchor onto, is the resistance gene, because that's what drives the selection for the plasmid, to make sure that it's there. So that should be there, in theory, after E. coli growth.
SPEAKER_00coli can't maintain these plasmids without that gene. In fact, when the FDA tells you that these residual plasmids are immaterial to plasmid manufacturing, they're lying through their teeth because you can't actually get a plasmid to grow in a coli without that antibiotic resistance gene. It's actually the most critical part of plasmid manufacturing when they tell you it's not material to it. It's a complete inversion of the truth. But the fact that they told them to look here is very peculiar, given if you look through the EMA documents, They have an assay to look at spike, but they never report it.
SPEAKER_00All right, so I'll touch on that in just a bit. In process two, what happens is E. coli doesn't just replicate spike. It has to replicate the entire circle, which means it should be the same copy number as spike can. There's a second artifact as to why that's not true in the case of these vials, is that they're using an enzyme to destroy this DNA afterwards that destroys can but doesn't destroy spike.
And so there's a hundredfold offset between can and spike when we look at this
SPEAKER_00through PCR, and we'll go through that data. OK, so this is very telling as to what's going on in the minds of the people who designed the trial and in the minds of what they're telling the regulators to look for. They're telling them to go look in the wrong place, particularly in light of this. This is the EMA documents that show they have a qPCR test that looks at spike. These sequences that you see up here, if you put them in the snap gene,
SPEAKER_00you'll see they land on spike. And this sequence is used to confirm that the plasmid actually has a spike insert and to confirm that the RNA is of spike origin after the IVT reaction. You'll see this is an RT PCR reaction. That means they're looking at RNA. But those same primers, you merely need to put into PCR and not run the 10-minute RT step in front of it. And you get answers for only DNA. They're using this to get answers for both DNA and RNA in this case.
SPEAKER_00So you have to ask, why did they go and make a CAN assay when they already were forced to validate a spike assay? And why don't they report the CT value for that spike assay? They don't report it because it's 100-fold higher, and we know that now. All right, so this is the game of hide the ball that they played with the regulators. They gave them an assay that can't find anything, even though they had already validated an assay that would find it. So Pfizer knows they're over the limit because this assay would have told them so. And then they went and made an assay for process one that would
find nothing.
SPEAKER_00And you have to ask yourself, how did a regulator fall for this? How were they given an assay to look at the pre-amplified template that didn't find the post-amplified product? They should have had a spike assay looking at post-amplification, and yet one exists in their documents that doesn't get used. This begins to show you the thinking that's going on in the people that designed the trial and how they hid this from the regulators. And the regulators still to this day are clueless of this deception because they keep saying,
SPEAKER_00well, the regulators looked and they used this CAN assay and they don't see anything. And no matter how many times we yell at them that you can't use a CAN assay during process one, what are you talking about? That's not what they amplify. It falls on deaf ears. Okay, I'm gonna go through a few other details here that befuddle QPCR, all right? QPCR is really not meant for task on this. And you'll understand why as I go through this, but they should have known it's not suited for purpose because
Moderna told them it
SPEAKER_00wasn't suited for purpose. It was in their patents that this does not work. And there's several reasons why it doesn't work that we'll hit on. Okay, so just a refresher, because I think some people aren't familiar with the difference between process one and process two. During process one, they would take this plasmid as an input, PCR amplify this DNA of spike, and then they would take that DNA. Now that the left side of this molecule has been drowned out
with amplification of
SPEAKER_00the right side of the molecule, they would then take that, put that through an IVT reaction to get RNA and to get rid of the DNA. They... in process two had to switch and change to using a DNAs. Prior to this, when they amplified the DNA, they put a biotin on here and they could pull the DNA out with a magnetic bead. And that's a more expensive process. So that slowed them down. And that's the reason for them wanting to go directly off the plasmids is they didn't wanna have to do the PCR step and the cleanup step. So they switched to using these plasmids where they can just
use an enzyme in an
SPEAKER_00attempt to clean this up. This enzyme will clean up and erase the left hand of this molecule. What we have found is that it does not erase spike because spike still has the RNA stuck to it. and that enzyme does not resolve RNA-DNA hybrids. So in both cases, process 1 and in process 2, the canned target is not going to find the content. So when you do this DNase reaction, you actually create a shotgun library. And this shotgun library is a fragmented library that looks,
you hope, is randomly fragmented. The problem you're gonna find that we're gonna go through is that it does not
SPEAKER_00randomly fragment. It actually hyper fragments the can region and under fragments the spike region by about 100 fold. And the reason PCR fails to sort this out is that your detection frequency is entirely dependent on how far apart your primers are. If you fragment this down to 150 bases, and design a 233 base pair product to measure this, you're not gonna find much because anytime there's a molecule that's broken between the primers, it can't amplify. So when you see papers like the ox paper using really large,
where they admit in their paper that the average fragment size is 100 bases or 150
SPEAKER_00bases, and then they go and design a 233 base pair amplicon to measure it, they are intentionally trying to deceive you, because this cannot amplify the majority of the material that's in there, because most of it's broken to be shorter than the distance of the primers. They also have a 63 base pair primer set for a can, and of course that amplifies more, because if its average size is 150 bases, there will be more molecules that are amplifiable. Now, one of the deceptions that occurs here is that when you amplify with DNA, you're only getting a quant of this part of the plasmid.
SPEAKER_00This is only 1 100th of the plasmid, maybe 120th of the plasmid. So then you apply some mathematical extrapolations, some models to say, hey, I measured 10% or 1% of the actual plasmid. I'm going to multiply everything by 100. And that assumes that every time you see one of these molecules that isn't fragmented between the primers, that there must have at one point been a full length plasmid from that. Therefore, I can safely multiply by 120 to measure how much was there. What this fails to capture is that anything that is fragmented
between the primers
SPEAKER_00doesn't get measured, and you then miss out on not just that 63 base pair region, but the other 7,000 you would have added to it. So it's a multiplicative error when you make this mistake. The other thing that it rests on is that the plasmid is evenly digested everywhere in the plasmid, and that's, we know, to be false. The canned regions get hyperfragmented, and the spike regions don't. So there's two mathematical extrapolations that this thing relies on that are both false and multiplicatively false, and that they're not just wrong a little.
SPEAKER_00The error they make, you have to multiply by 120, in the case of the 63 base amplicon, because that's 1 120th of the entire plasmid length. And to the extent that the plasmid is not uniformly digested, you're gonna make additional errors upon that. And we know that there's about a two log scale difference between what gets fragmented in spike versus can. So you've got 200 fold errors going on in this mathematical extrapolation.
SPEAKER_00So you could easily have a 10,000 fold mistake. you use pcr another way to look at this is to take a dna library that's been sheared and this is not a vaccine it's just a sheared library you can pull off the internet and what it looks like on an agilent electropherogram and to conceptualize this the 233 base per amplicon is only going to be able to capture the material in the red brackets and the 63 one will get the rest however nothing that you do with pcr is going to get it all it's always going to under measure it which is why you'll see in the speaker paper many of the lots
are under the 10 nanogram limit.
SPEAKER_00That's expected because this thing we know is an undercounting tool. Now, the other thing it doesn't measure is unexpected DNA. For PCR to work, you have to design primers to amplify your target, so you're only amplifying what you expect to be there. So if you give someone the canned region which you don't expect to be there, you'll find nothing. And likewise, the E. coli background DNA will never get counted in this measurement. This is why we have moved to fluorometry because it measures everything. Now, when you get a look at the read lengths from Oxford Nanopore, you can see that this is heavily shifted to the left,
SPEAKER_00which means a lot of the material is, in fact, small, but it has a long tail. And this complicates making any of these extrapolations. Another way to look at this, there's a 200 base pair limit right there. So if you design 200 base pair amplicons, you're only going to measure the DNA that's to the right. And some may say, hey, that's fine. That's what the regs say. 200 bases is safe because it's not functional. But we have 72 base pair pieces of DNA in this plasmid known as the SV40 promoter enhancer that are functional. They're nuclear targeting sequences, and they're down here.
SPEAKER_00And we know small DNA can integrate. So when it comes to using LNPs, the 200 base per limit is really rational. That was designed because DNA usually gets chewed from the ends in. So when you inject it naked, the 200 base per stuff should get chewed faster. That's not true when you LNP wrap it. 200 bases can still stimulate sea gas sting and can still integrate. So the 200 base per limit really doesn't make any sense once you start using LNPs. You need to measure everything. Okay, so let's touch on why Dnase 1 does not uniformly digest the
plasmid. This is actually something that's been known in the literature since 1997 from
SPEAKER_00Sutton et al, and it's been recapitulated in the literature from BioNTech themselves. You'll notice that there are lots of papers now, five peer-reviewed papers, that see this phenomenon. And I don't think everyone's caught on to why. So the most recent paper we have coming out will explain why. Okay, what you'll notice when we amplify the vector versus spike in our first paper, we had like a 5CT offset between those two,
SPEAKER_00okay? Vector is red, spike is blue. Why are those not on top of each other? That's because we believe, and we didn't fully appreciate it at this time, but that the vector is getting degraded by DNA someone more than spike is. That offset is then recapitulated in speaker, Speaker paper has this offset, which is more like five to seven CT offset. You'll see the spike is in red for many of the Moderna lots and the vectors in blue. That is a hundred fold difference. Pay attention to that number because that number is what we
consistently see study to study.
SPEAKER_00You look at Sonia Pakova's work. She has an offset between vector and spike in both of these. Sometimes it's erratic, sometimes it flips. Don't totally understand why that's going on. It's a sign that there's some manufacturing slop, which was observed in the trials. So this is perhaps congruent with what the EMA saw. Buchholz's work, he also has about a 10 scale, a 10 fold difference between these. These are the spikes over here. The three bar graphs on the right are the spike sequences and the other parts of this plasmid vector are on the left.
SPEAKER_00Now for this purposes, I spoke to Philip directly and he said, hey, take out this one assay here because I think there's an artifact there. That one is screaming hot and it was running a different plate and maybe it had a different... different standards, so just pull the outlier off and be conservative. If that were present, this would be a hundredfold difference, okay? All right, then you go and look at our work that has recently published as a preprint and it's on its way to publish shortly. Here, this is the most thorough work done to date in that we did 27
PCRs for every vial.
SPEAKER_00We did three different dilutions all in triplicate. So each one of these bars is three different PCR reactions at 1x, 1 to 10x dilution, 1 to 100x dilution. That series of dilutions is important whenever there's inhibitors potentially involved in the PCR because sometimes the 1x will give you an erratic result when there's an inhibitor that you don't see at 10x and 100x dilution. So you run all three. We also did this at three different targets in the plasmid. So we can see that all the regions in spike are coming out at a CT of 15,
SPEAKER_00and the regions in the plasmid vector are coming out at 22. That's a 7.14 delta CT. That means that's a 141-fold difference between the spike and the backbone. That is not an artifact. That is a real biological signal that there is a hundredfold more spiked DNA than canned DNA. So once again, the canned target that pharma is giving the regulators is meant to hide the ball. It's designed to. These are process two lots. This is not just a process one issue.
SPEAKER_00Over here are Pfizer lots. They have SV40. So in this case, there's no Moderna lots here. And you can see one of these artifacts occurring. Like in one case, we get a CT of like six. That's not real because we don't see one to 10 and one to 100 doing it. Whenever you get CTs that are below a CT of 10, the QPCR instrument is using that window from 0 to 10 to background subtract. And if you have signal come up there, it'll get confused. So this is why it's important to do the titrations. You really want to see each one of these bar graphs in the 1x
to the 1 to 10 to the 1 to 100.
SPEAKER_00They should be about 3.3 CTs apart. And then when you see that consistently, you know the assay is not inhibited. This is the right way to do an inhibitor reaction. You can't do an inhibitor reaction by putting DNA in here at CT of 5 or 10 because it's too hot for you to find an inhibitor. You have to do a serial dilution. The ox group failed to do this. You have to do a serial dilution to pick up inhibitors, and you want to measure that there's a 3.3 CT offset between all of these to gauge whether an inhibitor is there or not.
SPEAKER_00All right, so what we did in this study is we said, forget the 1x. There's too many artifacts in the 1x data, like this one here. So what we're going to do is go with the 1 to 10 dilution as the measurement for this, and then multiply all our numbers by 10 when we're done. And that will put us in the sweet spot of the dynamic range of the PCR machine. So again, the take-home message here is there's a large offset here, and that is biologically real. And Moderna knew this. They even wrote a patent saying, don't use qPCR because of this fragmentation problem,
SPEAKER_00and it doesn't measure everything that's there. So what's the mechanism behind this? We spoke about RNA-DNA hybrids, and we have a paper on this now that's coming out. RNA-DNA hybrids is after an in vitro transcription reaction. When you make RNA off that DNA, that RNA is self-complementary to the DNA, so it's wrapped up in a knot with the DNA. And when the DNase comes to chew this, it's like, I don't recognize that molecule. It's half RNA, half DNA. I'm not touching it. I'm going to go destroy the DNA that's double-stranded. That's my substrate. This isn't. So the DNase 1 does a great job destroying the can gene so you
don't find anything,
SPEAKER_00which is why they're pointing the regulators there. Well, all the spiked DNA is 100-fold higher, according to five different studies that have looked at this that are all peer-reviewed and published now. This is another way to depict the problem. The backbone gets degraded. You PCR can. You PCR spike. This is exactly what we see. You get about 100-fold difference. Here's another way to look at this. What we did is we took the vaccines, and then we treated them with Triton X. In this case,
SPEAKER_00the PCR does the heating for us, but we just treat it with soap, and that opens up the LMPs. And once you open up the LMPs, you can then ask, okay, what does DNase 1 do to that material? Can we get the CTs to move it all if we reapply DNase 1? And what happens when you reapply DNase 1 is you see spike stay the same, yet you see the ORI region, the vector, splits. So more DNA swan continues to erase their can region. It's not fully erased either. It's not zero, but it's below the limit. And it moves more when you add DNA swan back in again,
but it doesn't touch spike. If you go and grab the next enzyme down in the NAV catalog that's designed for IVT
SPEAKER_00reactions, for RNA-DNA hybrid digestion, you'll see spike move 6CT. Even blows apart the Ori region even further. Same thing is true in Pfizer and Moderna. You can see the ORI moves with more DNase 1. You add, the spike does not move, so it's protected. Put in DNase XT and bang, 12 CTs move when you add in the proper enzyme. So they're using the wrong enzyme. And this is not,
SPEAKER_00an accidental thing, I'd say, because these enzymes are sold by the same manufacturers, and there are many manufacturers that offer enzymes that are designed for IVT reactions. If you go to Thermo, they'll tell you to use EZDNase, which is known to hit IVT reactions. DuplexDNase out of NEB or DNA6T is really designed for IVT reactions. They chose an enzyme either being idiots or intentionally to leave some DNA behind because DNA is a nice adjuvant. They like adjuvants. Because of this, we're now getting 5,200 base pair pieces of DNA in these things,
SPEAKER_00and this is not non-functional DNA. This DNA, you can see, encodes all of this material with two different mammalian promoters. Mammalian promoters will signal the cells, the mammalian cells, to make RNA from here into spike and from here into NEO and CAN. So this is fully functional DNA, even though the regulators have told you it's not. And they've probably come to that conclusion because they've never actually measured the length of these molecules or they rely on a paper like the ox paper which uses alumina that can't actually amplify a 5,000 base per piece of DNA.
SPEAKER_00That stuff can maybe amplify a 500 base per piece of DNA and sequence it. Can't do 5,000. They can't see it. They're intentionally not looking with the right tools. Now, this should piss you off because Biontech knows about this. This is their paper, and they spell it out right here. The specific activity of DNA-S1 for RNA-DNA hybrids, however, is at least 100-fold below that for double-stranded DNA, and they cite Sutton et al. 100-fold. That's the number we're seeing in five different studies. They know the problem,
SPEAKER_00they're aware of it, and they're still pointing regulators to look in the wrong place. So they need to be taking the manufacturer's own advice on this. Read their patents. QPCR only attempts to measure 100 bases of DNA, and then there's a bunch of mathematical bullshit that goes on afterwards to try to claim how much DNA is there by saying, well, take 100, multiply it by 78, and that gives you an estimate for the full plasmid, and we'll just forget about the fragmentation issue that's going on here and how many primers drop out because of that.
SPEAKER_00That's probably immaterial when, in fact, it could be 90% of the DNA. It can't measure the E. coli DNA that's there. It can't measure small DNA that's beneath the size of the amplicon. And it can't look for unexpected DNA. It also assumes this uniform fragmentation, which doesn't occur. So, as I mentioned before, there could be a 100-fold error here. There could be a 100-fold error here. That gets you up to a 10,000-fold error rate. That's why when people are measuring this, there's nothing but argumentation in the literature because
they say you have to
SPEAKER_00use PCR, you can't use fluorometry. Well, that's an interesting comment because if you look through the docs, they use fluorometry to measure the dose of the drug, the RNA, and they try to claim that that's legitimate. You can use RNA or fluorometry to measure the RNA, but you can't use it to measure the DNA because there's crosstalk in the DNA. Let's go over that crosstalk argument. The important thing to know about fluorometry is it doesn't use primers. It has dyes that bind to these minor grooves, which means you have to have double-stranded material.
SPEAKER_00RNA is usually single-stranded, but in the case of these Pfizer vaccines and Moderna vaccines, the RNA is actually designed to fold back in itself and make double-stranded minor grooves. They do that so that RNA lasts forever. And that does mean that there's more crosstalk than the manufacturers have reported on these dyes, but we can measure that and account for that by using enzymes that erase it. Okay, there's a limitation here that Giorgio spells out. Even using fluorometry, we're only going to get 30% of the DNA signal when you chew it with DNA spawn. And when you make these molecules shorter, the dyes don't bind as well.
SPEAKER_00That's the summary of the paper. So you have to compensate. Now, we haven't been applying this compensation factor because it's already over the limit, so multiplying it by 1.7 isn't going to make it that much more of a difference, but people should know that this limitation exists, that after your DNAs chew something, if you take a 23 kb molecule like they did here, measure it with pico green, you'll get one number. DNA is treated, the same amount of DNA now is still in the vial. DNA does not destroy it, it just cuts it into smaller lengths. So it should stain to be the same amount,
but only stains to be 30% of the signal.
SPEAKER_00That tells you the dyes are not behaving on smaller DNA as well. Now, they'll say qubit's not standardized, whatever. The most expensive molecular biology we do today is running luminous sequencers because those runs are $20,000 a pull. So if you get the DNA concentration wrong, you've just blown 20 grand. And how do you get it wrong? Well, if you underestimate it and put too much on, you'll over-cluster the sequencer and it can't read anything. And if you under measure it by a factor of 10,
you won't get a whole lot of sequence out and your $20,000 run will effectively
SPEAKER_00feel like a $200,000 run. So it's very important to get this right. And if you go to Illumina's manufacturing and recommendations and thermos, they'll tell you to use a qubit to get this thing right. In fact, the ox paper that tried to refute our work very poorly tried to claim you can't use the qubit to measure the RNA, and what do they do when they actually go sequence the vaccine? They measure it with a qubit and put it on their luminar, because they do not want to use their qPCR data to make that mistake. They know the qPCR data is all over the map,
SPEAKER_00and it could easily over-cluster or under-cluster, and they get nothing. So that's a major contradiction in the ox paper. They claim you can't use qubit to measure this, then they turn around and use it when they want to sequence the vaccine, all right? That should tell you all you need to know. They are in fact conflicted and funded by pharma. So Sensible Biotech funds them and they're an mRNA company. So when we do this properly with qubits, the one thing we do do is we put in 200 fold more RNAs A than the manufacturer recommends to really make sure there's no question that we've
eliminated the RNA And we do that over a time series to make sure that its reaction's gone to completion.
SPEAKER_00In this case, when you do 200-fold more RNAsa, it's done in two minutes. Plateaus. Same signal at two minutes as at 10. In fact, you can do this and watch it in real time. It gets destroyed in seconds. The curve just drops right in front of your eyes. You can see it. And so we erase all the RNA, and we measure how much DNA is there. And in subsequent experiments, we've then gone further and said, okay, if it's truly DNA, hit it with DNase1XT and measure how much signal disappears after that, because that's a very specific enzyme for just DNA.
SPEAKER_00And that drops 240 nanograms when we do that. So we know this is DNA because the RNA has erased it, and then we subsequently follow up and erase what's remaining with the DNAs, all right? That's the best way to do this. And you'll see when you do this, you do not get a big difference between spike and Ori. And some might say, well, wait a minute, you guys said the vector gets fully destroyed. It gets cut into smaller pieces that still can stain, but it does not disappear like it does in PCR because it gets cut below the
SPEAKER_00amplicon size. Remember, the amplicon size in PCR, the closest you can get those primers is probably 63 bases because you need to have a probe in between the two of them. 25 bases for each primer and 25 bases for a probe. That's as tight as you can get PCR to go. Thermometry, however, can pick up 20 bases. All right, so we are seeing the same signal in ORI as we're seeing in spike because it is cut below the size the PCR can measure for how much we see is both. And then you can see the PCR in blue is all over the place, all right? This is why people are arguing over what PCR does because it's
entirely dependent
SPEAKER_00on the fragmentation process and the distance the primers sit. So what does pharma use to measure the RNA? They use something called ribo green. So when people say you can't use fluorometry to measure the DNA, well, you're using it to measure the dose of the drug. And they'll say, yeah, but there's crosstalk with the DNA dyes. It's not true. This is just to, you know, solidify this point. This is the EMA document showing they're using fluorometry. And then when they go to identify the RNA, they use that RT-QPCR on spike,
which is weird.
SPEAKER_00That's Pfizer showing it as well. Here's the EMA measurements of 10 vials that Pfizer cherry-picked for them. They vary by 815-fold, and the one outlier they claim has an incorrect DNA stock. You have to wonder how many times that is happening in production if they can't manage to get this straight on the 10 vials they cherry-picked for the EMA. It's probably wider than that, and then 815-fold variance. So this is a known problem, and they've been cited for it. Okay, so let's look at ribo green. They say the crosstalk in the DNA side is too great.
SPEAKER_00What is it on the RNA side? If you use ribo green, you get twice the amount of signal for DNA than you get for RNA on that dye. The crosstalk is 200-fold over the RNA signal. So here is 10 micrograms of RNA. You put in 10 micrograms of DNA and you get twice the RFUs. And if you mix RNA and DNA, you end up on the top curve up here. And if your DNAs treat that, it comes right back down. There's two lines actually here superimposed at the bottom line. All right, so this dye has 200% more signal for DNA than for RNA.
And then they turn around and claim you can't use fluorometry to measure DNA when
SPEAKER_00the documented crosstalk is this. This blue line is the RNA, right? It's like 7% of the signal that you get for DNA on the green line. If this were ribo-green, the DNA signal, the crosstalk, would be twice as high as the RNA signal. So we're talking about probably two orders of magnitude difference in crosstalk on the dye that they're using to measure the dose.
So they use fluorometry to measure the dose with a dye that has orders of magnitude
SPEAKER_00more crosstalk and then turn around and say, you cannot use these dyes to measure the DNA when those dyes have orders of magnitude lower crosstalk than what they're using to measure the dose of the drug. This is a very incoherent argument that they have. It doesn't make any sense, all right? So this is easily addressable by using RNAs and enzymes, okay? So hopefully that gave you some understanding of what's going on in process one versus process two and why there is a big charade going on here. But once you understand how they cherry picked assays to mislead all the
SPEAKER_00regulators, you realize that they did this quite intentionally. They pointed them toward CAN during process one knowing they'd find nothing. When they went into process two, they knew they had to have CAN. However, they also know that that's not going to find everything because the RNA-DNA hybrid stuff is documented in their own papers. And it's been known since 1997. So I won't go through the rest of the presentation because I think you've seen this. But that hopefully explains the game of hide the ball that's going on that the
SPEAKER_00regulators have not been quite getting their head around. So best of luck.
POWERFUL MOMENT with FAUCI in the docket. The good doctor can’t even LOOK at the people he impacted. Sen. Bernie Moreno confronts the megalomaniac with the impact of his TERRIBLE Covid policies. JUST. TURN. AROUND....
3 years ago, this day. Jenny Erikson & I teamed up with Restore Chilhood and lead a Rational Ground delegation to Capitol Hill. That delegation included Jay Bhattacharya. We voiced our opposition to terrible Covid...