Practice choosing a palliative technique and deciding when stereotactic body radiation therapy fits the clinical situation. Chapters00:00 Opening and two recall questions 01:36 Her case: two growing sites 03:29 The named set, its limits and her drugs 07:13 Simulation, liver motion and contours 11:17 Technique and the iliac site 14:08 Plan review: coverage, organs and her values 17:09 The duodenal maximum and the cross-checks 19:43 The board answer 20:56 Plans A and B: revise, accept, escalate 23:56 The bleeding breast and when to escalate 26:21 Traps, Board Blitz and closeThe patients in this episode are invented for teaching. For education only. This is not medical advice. Notes and practice oral boards: radoncsmartlearn.com
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Transcript
From the show. Tap a time to play from there.
Avery: Welcome back to Rad Onc Smart Review, Breast Oncology. Eden: This is Episode thirty-eight: Workshop: palliative technique and SBRT selection. Avery: So, a stereotactic liver plan comes back from the planner, and you bring it up on your monitor. The tumor is covered, and nearly every metric on the dose volume histogram passes. Eden: But then your eye catches one issue. The hottest speck of the duodenum is over its limit. It is just too hot. Avery: Yeah. And right beside that screen waits a second plan, this one for a right hip bone. It's a hip that already had radiation, and now loops of
small bowel are lying right up against the target. Eden: The question for both of these screens is simple. Do you accept, revise, or escalate? Avery: Today, we are taking two growing metastases from simulation to plan review against one named constraint set. And then we are going to finish with a palliative field for a bleeding breast cancer. Eden: But before we get into the simulation room, we have two recall questions for you, to test your memory. In Curb's breast cohort, what did stereotactic radiation to the growing sites do for progression-free survival? Eden: Pause and answer. Avery: Got your answer?
In Curb's small breast cohort, SBRT, or stereotactic body radiation therapy, to the growing sites did not significantly improve progression-free survival. Eden: Okay, moving to your second recall question. Which HER2-directed antibody drug conjugate carries a boxed warning for interstitial lung disease? Pause and answer. Avery: All right. The drug is trastuzumab deruxtecan, and lung inflammation of grade two or higher means stopping it for good. Eden: Yeah, that boxed warning is for interstitial lung disease, or ILD.
Avery: So we have navigated the recall, and now it is time to step into the clinic. Last time, we met our patient about four years after her cancer first spread, with spinal cord compression. Today we step back about two years. Avery: She was sixty-one when her cancer first spread to bone, and she is now about sixty-three. Her disease is estrogen receptor positive and HER2 low. Avery: For the past twenty-six months, she's been on a combination of letrozole and ribociclib. Eden: And here's where the
biology of her disease intersects with our radiation strategy. After twenty-six months on the systemic regimen, the rest of her metastatic disease is still quiet. Avery: Right. But two specific sites have started to grow. This is what we call oligoprogression. Eden: Exactly. So let's map out these two sites. Site A is a brand-new one point eight centimeter lesion located in liver segment six. Avery: And this area has never been irradiated before. But because of its location in segment six, it sits near the
hepatic flexure of the colon and the duodenum. Eden: Then we have site B. This is an enlarging lesion in the right iliac wing of the pelvis. This spot previously received an eight gray in one fraction palliative treatment for pain. Avery: Yeah, and that single fraction did its job. The pain settled. But now the lesion is growing again, and we have loops of small bowel resting near its medial surface. Eden: So she was presented at the multidisciplinary tumor board, and she chose stereotactic treatment to both of these growing sites, while staying on letrozole and
ribociclib. Eden: But the overarching goal here is vital to understand. Avery: We are not doing this to try and cure her metastatic disease, right? And we are not doing this with the expectation of extending her overall survival. Eden: Exactly. The goal is focused and pragmatic. We are trying to buy her more time on her current systemic drugs. Avery: To do that safely, we need a rigorous set of rules. We can't just guess what doses the duodenum or the previously irradiated bowel can handle. Her liver plan is going to be checked against one named constraint set. Eden: Specifically, we are using
the Sabr-Comet-ten protocol constraint table, and we are reading from its five fraction column. Avery: Right. It doesn't just give you one list of numbers. Eden: No, it is divided into a serial organ table and a parallel organ table. And within those tables, there are different columns depending on whether you are delivering the treatment in one, three, or five fractions. Avery: It is built on the foundation of two earlier clinical trials, NRG LU zero zero two and the earlier Sabr-Comet. Eden: And what makes this protocol interesting from a
planning perspective is how it handles the prescription. It prescribes by the number of fractions you are using, not by the anatomical site of the tumor. Avery: So whether you are in the lung, the liver or the adrenal gland, if you are using the five fraction column, the protocol prefers a dose of thirty-five gray delivered to the edge of the planning target volume, or PTV. Eden: But it provides a window of acceptability, accepting doses anywhere between twenty-five and forty gray. Centers will generally pick their own standard dose inside that range. Eden: For our patient's liver
lesion, we are targeting thirty-five gray in five daily fractions. Avery: That gives us flexibility on the target dose. Now let's say the set's limits aloud, because each one matters today. Eden: Right. Before we even get to the numbers, we have to acknowledge the context of the trial that adopted this set. The Sabr-Comet-ten trial was a mixed histology trial. Avery: It enrolled patients with various types of primary cancers presenting with four to ten metastases. Eden: Because it wasn't written for breast cancer alone, the trial itself won't be able to show us outcome differences based on tumor type.
We are borrowing a general metastatic framework and applying it to our breast cancer patient. Avery: We also have to respect the exclusions that were built into this protocol. These constraints were designed for a stereotactic treatment delivered without concurrent targeted drugs. Eden: Yeah, the trial excluded targeted therapies around the time of the radiation. And the protocol excluded any target that had substantial overlap with an earlier radiation field. Avery: Now, other prior radiation was allowed in the trial, but with conditions. The added-up plan had to meet
the table limits using biologically effective doses, and it required consultation with a trial lead. Eden: That exclusion regarding targeted drugs brings us to a pre-simulation hurdle. Before we even schedule her for a CT scan, we have to check her drugs. Avery: She is taking ribociclib, which is a CDK four six inhibitor. Ribociclib is known for its potential to raise liver function tests. In fact, the drug's label asks for liver tests before starting and during treatment. Eden: So, as a practice step, we
check her liver tests before proceeding with liver SBRT. But checking the tests is only step one. Avery: On one hand, you have the Estro-endorsed radiation consensus, which says that CDK four six inhibitors could be offered with palliative or ablative radiotherapy outside the brain. Avery: That position is based on retrospective studies. Eden: Exactly. On the other hand, the trial behind our constraint table, Sabr-Comet-ten, kept targeted drugs away from the radiation. Because of this difference, you cannot make this decision alone.
Eden: You have to sit down with medical oncology, look at her liver tests, and make a shared decision. Avery: As for the letrozole, the hormone therapy, that continues. The protocol allowed hormone therapy during the radiation course. Eden: And just to close the loop on liver safety, the protocol also excluded treating liver lesions in patients who already had moderate or severe liver dysfunction. Avery: So assuming her liver tests are acceptable and we've mapped out the drug plan with medical oncology, we finally move into the simulation room. For a lesion in the liver, the protocol uses a four-dimensional
CT. Eden: The immobilization follows the earlier Sabr-Comet protocol. Positioning, the timing of the intravenous contrast, and the MRI fusion used to pinpoint the tumor all follow your department practice. Avery: The liver simulation is technical, but the simulation for the iliac bone site involves a different kind of challenge. You must request the old plan. Eden: Yeah. You need the original imaging, the old target volumes, and the complete dose distribution from that eight gray single fraction she received. You cannot plan the new course
blindly. Avery: Which brings us to the physical mechanics of treating the liver. Avery: When you look at her four-dimensional CT scan, which captures the anatomy across the entire breathing cycle, you see large craniocaudal motion of the liver lesion. Eden: It is moving significantly up and down with every breath she takes. Avery: So here is your first workshop question. What are your options and how do you choose? Pause and answer. Eden: Have your answer? Measure it first. Eden: According to AAPM Task Group seventy-six, if the motion
is greater than five millimeters and a method to manage it is available and the patient can tolerate that method, then motion management is appropriate. Avery: Right. And for stereotactic treatments, where margins are tight and the doses are ablative, that threshold for intervening might be lower than five millimeters. Eden: Motion management is also appropriate whenever it helps spare adjacent normal tissue, which in her case is what we need to do for the duodenum and the colon sitting right next to segment six. Avery: So once you've measured
it and confirmed it's moving too much, you essentially have two main approaches. You can either encompass the full motion, or you can actively reduce the motion. Eden: If you choose to encompass it, you create an internal target volume or ITV. This essentially draws a boundary around every position the tumor occupies during the breathing cycle. Eden: That is the task group's motion-encompassing approach, not a protocol rule. Avery: Alternatively, you can actively reduce the movement. You might use abdominal compression to restrict how deep
her breaths can be. Avery: You could use breath hold techniques, where she holds her breath at a specific point in the cycle while the beam turns on. Eden: Or, depending on your technology, you might use gating, where the machine only fires when the tumor falls into a specific window, or tracking, where the beam moves to follow the tumor. Avery: How do you choose among these? You choose based on what your machine is capable of doing reliably and what your patient can tolerate on the table. Eden: Once the simulation is done and we have managed the motion, we sit down to draw the
contours. Avery: For the liver lesion, the protocol adds no margin for microscopic spread. This means your clinical target volume, your CTV, is equal to your gross tumor volume, your GTV. Avery: The planning target volume, the PTV, is then added to account for setup uncertainties. Avery: Depending on the specific anatomical site, the immobilization used, and the overall setup accuracy, the protocol allows a PTV margin ranging from two to five millimeters. Eden: But for a liver lesion, the PTV margin is five millimeters.
You also contour the organs that fall within five centimeters of that PTV. Avery: For a liver lesion, the healthy liver structure excludes the tumor itself. It is the total liver volume minus the GTV, as the UK consensus names it. Eden: But our protocol does not define one. Avery: Moving our attention to the contours for the iliac site. The task involves drawing out the recurrent bone tumor and the nearby loops of bowel. But the key step here is the dose overlay. Eden: You must overlay the old dose distribution from her prior
treatment onto today's newly acquired CT scan. Eden: The European re-irradiation consensus declares that a three-dimensional overlay is mandatory whenever the old plan exists in an electronic format. Avery: How to add an old plan to a new one, step by step, is its own topic. Eden: Let's talk about the technique we use to deliver these doses. For the liver, the protocol is adaptable. You can use static beams or rotational arcs. Both fit the protocol. Avery: But the internal dosimetry rules are specific. The protocol requires you to
prescribe to the sixty to ninety percent isodose line around the PTV. And it wants hotspots to exist inside the GTV. Eden: Yeah, a uniform, homogeneous dose across the target is not the aim. Avery: Achieving a sharp falloff toward nearby structures like the duodenum is good planning practice, though a specific gradient metric is not written as a protocol line in this set. Eden: We should also note that stereotactic techniques for the spine and the brain have their own rules, which are separate topics. Avery: Right. So the technique for the liver is about shaping the dose
gradient, but the iliac site presents a different problem. Site B is classified as type one re-irradiation. Eden: This means the new course of radiation overlaps the old radiation field. And that overlap includes the nearby loops of bowel. Avery: Which brings us to your second workshop question. Why can't you plan the iliac site from the same Sabr-Comet-ten table? And is a conventional retreatment the answer instead? Pause and answer. Eden: Okay, here is the answer. Because it is type one re-irradiation right next to the
bowel. As we established earlier, the named constraint set excluded targets with substantial overlap with prior fields. Avery: Yeah, and it sent any other earlier fields to an added-up plan review. And the UK consensus states that its SBRT constraints do not apply to re-irradiation. Eden: You might wonder if the Avatar trial gives us an out. Avery: Right. Avatar was a single-arm trial investigating stereotactic treatment in patients on targeted drugs similar to hers. Avatar did not exclude treating a site that had received a small
earlier dose. Eden: So technically, her old single treatment of eight gray did not rule out the iliac site based on target dose history in that trial context. But that trial rule says nothing about the tolerance of the adjacent bowel. Avery: So if SBRT is so complicated here, what about conventional retreatment? Avery: Astro strongly recommends a single eight gray treatment, twenty gray delivered in five fractions, or twenty-four gray in six fractions when retreating a symptomatic non-spine bone metastasis. Eden: But the key word there is
symptomatic. Those conventional courses are for pain relief. Our patient's iliac lesion is not painful today. She is asymptomatic there, and we are treating it for oligoprogression. Avery: When it comes to using stereotactic retreatment for a non-spine bone lesion, there are no prospective data available. Astro guidelines cite one retrospective series on this topic and ask for more study. Eden: So the optimal course of action for this iliac site is not settled yet. With those rules established, let's get to the plan review for the liver. We take this evaluation in a specific order. Avery: We always evaluate the
target coverage first. The protocol wants ninety-five percent of the PTV to be covered by the full prescription dose. Avery: It also wants ninety-nine percent of the PTV covered by ninety percent of the prescription dose. Eden: Beyond just covering the target, we have to evaluate the spillage of the dose. The volume of tissue receiving the prescription isodose should be less than one point two times the volume of the PTV itself. Eden: There are some minor exceptions allowed for small targets, but we want the high
dose tightly confined. Avery: And as a critical safety check, the protocol also has each plan peer-reviewed before the patient receives their first treatment. Eden: Once the target coverage is verified, we move our attention to the normal organs. Now we have to read the dose to these organs in two distinct ways because different tissues fail by different mechanisms. Avery: First, we look at the serial organs. Think of the duodenum, the small bowel, the stomach, and the spinal cord. Serial organs are protected by limiting the maximum dose.
Avery: You always read the hottest small volume on the dose volume histogram. Eden: The second category involves the parallel organs, like the liver itself or the kidney cortex. Avery: Right. For these organs, what matters is how much of the organ you spare. Eden: So they are protected by sparing a critical volume, typically about a third of the organ. You are essentially asking the dose volume histogram, does enough of this organ stay at or below a safe limit? Avery: This is what we call a cold check because you are ensuring a sufficient volume
remains relatively cold, and it is read from the left side of the DVH curve. Avery: Let's run through the exact values for our patient's liver plan, pulled from the Sabr-Comet-ten table, five-fraction column. Eden: We will start with the serial organs. Each serial value represents the maximum dose that the hottest named volume of that organ is allowed to receive, starting with a structure right next to our target, the duodenum. Avery: The limit is twenty-six gray to the hottest zero point zero three cc. Moving to slightly larger
volumes of the duodenum, it is eighteen point five gray to five cc and fourteen point five gray to ten cc. Eden: Next, we look at the stomach and the rest of the bowel. For the stomach, the limit is thirty-five gray to zero point zero three cc and twenty-six point five gray to ten cc. Avery: For the jejunum or the ileum, the small bowel, it is thirty-two gray to zero point zero three cc and twenty gray to thirty cc. Avery: For the large bowel, the colon, the limit is forty gray
to zero point zero three cc and twenty-eight point five gray to twenty cc. Eden: Finally, we perform the cold checks on the parallel organs, specifically the healthy liver and the kidneys. We must ensure that at least seven hundred cc of liver receives twenty-one gray or less. Avery: And we need at least two hundred cc of kidney cortex, both kidneys together, receiving eighteen gray or less. Eden: Which brings us to workshop question three. Which constraint on the liver plan do you check first, and why that one specifically?
Pause and answer. Avery: All right. The answer is you check the duodenal maximum first. The duodenum is a serial hollow organ right next to our target in segment six, and it fails by its hottest small volume. Eden: So you verify that it receives no more than twenty-six gray to the hottest zero point zero three cc, from the Sabr-Comet-ten table, five-fraction column. Avery: You then cross-check the tables from a breast trial, NRG BR zero zero two. The limits in that trial were adapted from earlier protocols. Eden: If you look at Table
five-nine, the five fraction table in that protocol, it gives a limit of thirty gray under half a cc of the duodenum and eighteen point three gray under five cc. Avery: Yeah, that eighteen point three gray to five cc from the breast trial is slightly stricter than our named set's limit, which was eighteen point five gray at five cc. When you find a stricter cross-check, you must flag it. Eden: You check the duodenal max, then you check the rest of the bowel, and then you check the parallel liver to ensure enough volume stays cold. Avery: Now, these constraint
sets differ not just in the dose limits but in the exact volumes they measure. For instance, the UK consensus lists thirty gray to the hottest tenth of a cc of small bowel as its optimal level. Eden: That may be stricter than our named set's thirty-two gray to zero point zero three cc of jejunum or ileum. And the UK values are for stereotactic treatment alone, not for re-irradiation. Avery: It's also important to realize that these constraint sets often share a historical ancestry.
They borrow from earlier papers and older protocols. Avery: Therefore, if you see two different guidelines agreeing on a specific row of numbers, that agreement is not independent proof of safety. Eden: You have to compare like with like. You must name the set you are using and state the exact column or table you are pulling from. Avery: When a cross-check from another major protocol is stricter than your named set, you flag it to your physics team and you escalate the discussion. You never just swap the limits silently in the background. Eden: And why do we take this
level of care? Avery: Because in the earlier randomized phase two Sabr-Comet trial, three out of the sixty-six patients treated in the Sabr arm had a death that was judged to be possibly, probably, or definitely treatment related. Eden: Okay, it is time to synthesize all of this. Avery: Give me the sixty-second board answer. The examiner asks how you plan and check her liver SBRT. Pause and draft it. Eden: This is a woman of about sixty-three with estrogen receptor positive, HER2 low metastatic breast cancer on
letrozole and ribociclib, with a growing one point eight centimeter lesion in liver segment six near the duodenum. Eden: The aim is more time on the same drugs, not longer survival. I check her liver tests and agree the ribociclib plan with medical oncology. Letrozole continues. Eden: I simulate with four-dimensional CT, measure the motion, and manage it if large or if that spares the duodenum. The CTV is the GTV, with a five millimeter PTV margin. Eden: I prescribe thirty-five gray in five fractions to the PTV edge and review against the
Sabr-Comet-ten table, five-fraction column. Coverage first, ninety-five percent of the PTV at full dose with hotspots in the GTV. Eden: Then the duodenal maximum, twenty-six gray to the hottest zero point zero three cc. Then the bowel, then whether enough liver stays cold. I state the set's limits. Eden: It was adopted by a mixed-histology trial of four to ten metastases, run without targeted drugs around treatment. I flag any stricter cross-check to physics, and the plan is peer-reviewed before treatment. Avery: Now for the drill. Let's look at the plans the
planner sent over, starting with plan A one for the liver. It covers the target well, but as we noted, the duodenal maximum is over the named limit. Eden: The action here is to revise. You lower the dose within the protocol range, or you allow the PTV coverage to give way right where it touches the duodenum, all while keeping the GTV itself covered. Avery: You might consider adding a planning risk volume or PRV around the duodenum to help the optimizer push the dose away. But be aware that a duodenum PRV
is a local institutional choice. Avery: The protocol's own rules for creating a planning risk volume apply to the spinal cord. Eden: You also cannot just dilute the dose by spreading it over more days. She is already planned for five fractions, which is the protocol's longest allowed schedule. Avery: Going to any longer fractionation scheme means leaving the named set, and that would be an escalation, not a revision. So to execute the revision, here's the text you would send back to the planner. Avery: Hey, on the liver plan,
the duodenum max is over the Comet-ten five fraction limit. Can you add a duodenum PRV and let coverage give a little where they overlap? Everything else the same. Eden: Now, if Plan A two comes back and this time it meets the set, the action is simple. You accept it right after it goes through peer review. Avery: But then we turn our attention to Plan B, the iliac site. On this new plan, a small loop of bowel that sits inside the old radiation field is receiving a high dose. Eden: The action here is to escalate, and we do this without
a fixed answer. You pause the iliac plan. Avery: You review the added up dose with your physics team and the attending physician, and then you decide on the path forward in a shared discussion with the patient and the multidisciplinary tumor board. Eden: The steps for this escalation process are very specific. You have to retrieve the old plan. You overlay it onto the new anatomy. You convert both the old and new doses to equivalent doses. Avery: You add them up. You compare that total dose
against established limits. Crucially, you do not count on tissue recovery. Eden: And finally, you decide with her if the risk is worth the potential benefit. Eden: If the electronic file of the old plan cannot be found, the re-irradiation consensus does allow for a cautious estimate, which assumes that the old prescription dose was given evenly across the region. Avery: If during this process the iliac site becomes painful, you fall back on the established guidelines. Conventional retreatment is the
guideline option. Avery: Stereotactic retreatment for this non-spine bone lesion only comes up as an option after that review, and it rests on retrospective evidence. Eden: So here is the text you send to the planner for this one. Hold off on the iliac plan for now. I want to look at the old plan with physics first. Avery: Let's shift gears for our third case. We are stepping away from stereotactic ablation and looking at a completely different patient profile. Avery: An eighty-four-year-old woman presenting with a bleeding, fungating right breast
cancer. This is a purely palliative scenario. Eden: One of the treatment schedules drawn from the Royal College range is six gray once a week, to a total dose of thirty to thirty-six gray. Eden: However, because this regimen rests on a retrospective series and carries a low-grade recommendation, it is one option, not a standard. Avery: In the clinic, department practice for this type of bleeding superficial lesion involves using simple radiation fields that are shaped to the symptomatic tissue. Eden: Because this is a
fungating mass on the surface of the skin, we often need to use bolus, a tissue equivalent material placed on the skin to raise the surface dose. Avery: A bolus consensus advises placing the bolus material on the patient during the simulation scan, and making sure it is cut and shaped for the best possible fit to reduce any air gaps. Eden: While that consensus document was originally written for post-mastectomy treatment of early-stage breast cancer, its statements on managing a fungating mass reach into metastatic disease. Avery: So we reviewed plan C,
which is her breast field. But when we look at the setup images, we see a distinct air gap trapped underneath the bolus, right over the ulcerated tumor. Eden: The required action here is to revise. You must refit and reshape that bolus material, and then you must check the fit and the surface dose according to your department's protocol. Avery: The reason we must revise this is rooted in fundamental physics. Eden: As a matter of general physics, a gap between bolus and skin can lower the surface dose that the bolus is there to raise. Avery: Which brings us to
workshop question four. Looking at all these scenarios, what would make you escalate rather than revise? Pause and answer. Eden: Ready? You escalate when the target substantially overlaps an earlier field, which our named set excluded. You escalate when earlier radiation requires an added-up plan review, or when the old plan is missing. Avery: You escalate when meeting a serial organ limit would cost you GTV coverage, pushing you beyond what the protocol's levers allow. Or you escalate when a cross-check from another protocol is stricter than your
named set. Eden: You only revise when a protocol lever can fix the problem while keeping you inside the boundaries of the named set. Avery: Now let's run through three planning traps you need to avoid in the clinic. Trap one. Eden: Applying the Sabr-Comet-ten table to the iliac site as if it were untreated tissue. That site is type one re-irradiation, and the bowel dose from both courses is reviewed before any plan is set. Avery: Trap two. Eden: Using a free breathing PTV for a moving liver lesion
without measuring the motion. Measure it on four-dimensional CT first, then choose how to manage it. Avery: Trap three. Eden: Starting liver SBRT on ribociclib without liver tests or a joint decision with medical oncology. Avery: Let's move straight into the Board Blitz. I am going to give you two quick cases. Answer each one before we do. Case one, name the constraint set you used for her liver SBRT and its main limit. Pause and answer. Eden: The answer is the Sabr-Comet-ten protocol constraint table, read from the five fraction column for a five
fraction plan. Eden: It was adopted by a mixed histology trial evaluating patients with four to ten metastases, not by a dedicated breast cancer trial. Each value belongs to its own set and its own fraction column. Avery: Case two. On her liver plan, the breast trial's five fraction table is stricter than the named set at one duodenal volume. What do you do? Pause and answer. Eden: You name both values alongside their volumes. Eighteen point three gray under five cc against eighteen point five at five cc. You flag the stricter one to physics and you escalate.
Eden: Choosing either value silently hides the difference. Avery: Finally, let's talk about how you translate all of this into a conversation with the human being sitting in the exam room. Eden: If she asks what happens next, try this. We plan focused radiation to the liver spot, in five treatments, after we check your liver blood tests, and your cancer doctor and I will agree how your pills fit around it. Eden: The hip bone had radiation before, and some bowel lies close to it. So before we treat it again, we will look at your old plan with
our physicist and decide with you. Avery: To summarize today's workshop, we started with two plans. The liver plan, which had the hot duodenum, is revised using the protocol's own levers. Avery: The iliac plan, because of the overlapping bowel and the prior dose history, is paused and escalated. Eden: For each plan you evaluate, you name the set, name its column, name its limits, and then decide whether to accept, revise, or escalate. Avery: In the next episode,
Episode thirty-nine, brain metastases and leptomeningeal disease, we meet a new patient, a woman with HER2 positive breast cancer and new headaches, and we decide how to treat the metastases in her brain. Eden: Get show notes and complete practice oral boards at Rad Onc Smart Learn dot com, and subscribe for our next episode. Thanks for tuning in!
Test your reasoning in a comprehensive breast oral board. Pause at each question, commit to your answer and compare it with the discussion. Chapters00:00 Opening and the first patient's case 02:04 First patient: surgery...
Practice reading breast trial endpoints and explaining absolute benefit and uncertainty to a patient. Chapters00:00 Opening and two recall questions 01:46 Her case, three questions and the board answer 04:00 Endpoints:...
Explore how endocrine therapy, menopausal symptoms and access to care shape the patient’s experience after initial treatment. Chapters00:00 Opening and two recall questions 02:31 Her case and the board answer 05:07 Why...
Plan the transition from active treatment to surveillance, including follow-up visits, symptoms to evaluate and responsibilities at the survivorship handoff. Chapters00:00 Opening and two recall questions 02:23 Her case...
Review the presentation and management questions raised by Paget disease, phyllodes tumors and other uncommon breast tumors. Chapters00:00 Opening and two recall questions 01:22 Her case and the board answer 02:41 What...