Episode 12: Pancreas Planning Workshop: Simulation, Targets, Motion, and Constraints.A pancreatic radiation prescription must fit the patient's anatomy and the motion seen at simulation. In this planning workshop, we work through simulation, image registration, target definition, respiratory motion, and organ-at-risk constraints. The discussion connects technical choices with treatment safety when the tumor lies close to the duodenum and other sensitive structures.
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Transcript
From the show. Tap a time to play from there.
Speaker 1Welcome back to Rad Onc Smart Review, Gastrointestinal Series.
Speaker 2This is Episode 12, Pancreas Planning Workshop. Simulation, Targets, Motion, and Constraints.
Speaker 1A confident pancreas prescription still has to survive a close look at the anatomy. A patient has locally advanced pancreatic head adenocarcinoma without progression after four months of systemic therapy. The referral says, please give 50 gray and five fractions.
Speaker 2Before we agree to that dose, what do we actually know about the duodenum and the scans?
Speaker 1Well, the tumor abuts the duodenum. And, you know, the diagnostic scan was acquired in a different breathing state from the simulation scan.
Speaker 2Oh, a different breathing state.
Speaker 1So, I mean, do you accept the prescription and start contouring?
Speaker 2Give me the 60-second board answer.
Speaker 1No. First, confirm the indication, clinical goal, fractionation... concurrent therapy, and the protocol or atlas governing targets and constraints. Review pre-treatment and post-chemotherapy pancreas protocol imaging. Simulate reproducibly with intravenous contrast, unless contraindicated, then slices, consistent preparation, and patient-specific respiratory motion assessment. Use motion management for SBRT and daily volumetric image guidance, preferably with fiducials and soft tissue verification. contour stomach, duodenum,
Speaker 1small bowel, and large bowel separately. Then build the target according to the selected strategy, postoperative atlas, conventional definitive field, gross disease SBRT, or the newer dose-escalated high-risk and low-risk CTV approach. Apply the constraint set belonging to that fractionation and technology. Protect critical hollow viscous before maximizing target coverage. If anatomy changes enough to violate constraints or compromise coverage, adapt, replan, de-escalate, or use more fractions.
Speaker 2And that's the planning pearl to keep beside the referral. A prescription is not a plan.
Speaker 1Now, let's return to our patient. Imagine Ms. Patel sitting across from you. She is 65 with a pancreatic head primary that encases the superior mesenteric artery. After modified fulfirinox, there's no distant progression and no surgical path to an R0 resection.
Speaker 2Got it. And where does it sit?
Speaker 1The tumor touches the second portion of the duodenum for about two centimeters, but it does not visibly invade or ulcerate it.
Speaker 2So abutment, not visible invasion or ulceration. What is the team hoping to achieve?
Speaker 1Honestly, the team wants durable local control and a chemotherapy break.
Speaker 2You know, I'd start by naming the treatment package. The ASTRO guideline supports 33 to 40 gray in five fractions for selected locally advanced disease.
Speaker 1Right, 33 to 40.
Speaker 2But the 2025 NRG dose escalation consensus describes a different strategy, such as 50 gray to a high dose volume and 33 gray to a low dose elective volume in five fractions. Those are not interchangeable prescriptions.
Speaker 1So what additional anatomy, expertise, and evidence qualifications come with the dose-escalated package?
Speaker 2Well, the second requires appropriate anatomy, planning expertise, stringent hollow viscous protection, and often adaptive or equally robust image-guided technology.
Speaker 1That's a tall order.
Speaker 2It is, and its clinical justification remains based on consensus and non-randomized evidence rather than phase 3 comparisons.
Speaker 1Yeah, and once the package is named, we can make the simulation match it.
Speaker 2So position the patient supine when feasible, with arms above the head, and individualize immobilization that is comfortable enough to reproduce. And no particular commercial immobilization device is essential.
Speaker 1Then the brand isn't really the point. What does the patient need to reproduce each time?
Speaker 2What matters is that the patient can maintain the selected breathing strategy for simulation and every fraction.
Speaker 1And then use consistent stomach and bowel preparation. The NRG Atlas discusses fasting for treatment and avoiding excessive oral contrast or fluid that distends the upper gastrointestinal tract.
Speaker 2Can a small amount still help identify bowel, though? I mean, as long as that anatomy is reproducible?
Speaker 1It can. A small amount of oral contrast or water may help identify bowel. But honestly, reproducibility matters more than creating an impressive simulation image that cannot be repeated.
Speaker 2For CT-based treatment, use intravenous contrast, unless contraindicated. And the 2025 NRG Atlas suggests a triple-phase approach when feasible.
Speaker 1Triple-phase. Walk me through it.
Speaker 2Approximately 25 seconds for arterial imaging, 40 seconds for the pancreatic phase, and 70 seconds for portal venous imaging.
Speaker 1And realistically, if only one contrast scan is practical?
Speaker 2If only one contrast scan is practical, then, you know, approximately 40 to 50 seconds can improve tumor and vessel visualization. and keep slices at two millimeters or less through the target.
Speaker 1When we bring in the diagnostic CT or MRI, where should we check that the fusion really fits?
Speaker 2Fuse the diagnostic pancreas protocol CT and MRI when they add information, but confirm registration around the tumor and vessels rather than trusting a global fusion.
Speaker 1Motion assessment is required, but one method is not required for every patient.
Speaker 2So which methods?
Speaker 1If treatment will use free breathing, four-dimensional CT is a standard way to measure respiratory excursion. Breath hold, abdominal compression, respiratory gating, and tracking are alternatives or complements.
Speaker 2Let's keep the recommendations separate, though. What does ASTRO say for SBRT? And what threshold does NRG use for dose escalation?
Speaker 1ASTRO recommends a respiratory motion management technique for pancreatic SBRT.
Speaker 2Sure. And the other group?
Speaker 1The NRG Dose Escalation Atlas calls for a strategy when target movement exceeds 5 millimeters.
Speaker 2Does conventional treatment have to use that exact threshold and technique, though?
Speaker 1No. For conventional treatment, the threshold and technique can differ, but measured motion must match the ITV, PTV, and intrafraction verification plan.
Speaker 2Think of motion management like selecting a lane on a bridge.
Speaker 1Okay, I'm with you.
Speaker 2You may use breath hold, gating, tracking, or an ITV, but the lane markings, guardrails, and daily verification must describe the same route.
Speaker 1Oh, I like that bridge analogy. So in an actual plan, what would a mismatched system look like?
Speaker 2A breath hold scan with a free breathing treatment margin. That's a mismatched system.
Speaker 1Right. Fiducials are highly valuable for CT-guided SBRT, and ASTRO recommends daily guidance with fiducials and volumetric imaging.
Speaker 2Mm-hmm. And the atlas?
Speaker 1The NRG atlas highly recommends fiducials, but it permits a metal biliary stent as a surrogate when needed.
Speaker 2Permitted, yes, but is the stent an equivalent surrogate? And what about just matching bone?
Speaker 1No. A stent can shift relative to the tumor, so it is not equivalent to multiple well-positioned fiducials or direct soft tissue visualization. And bony alignment alone is honestly a poor pancreas surrogate.
Speaker 2So how do we inspect both the target and its neighbors and then kind of keep watch during delivery?
Speaker 1You use cone beam CT, CT on rails, or MR guidance to inspect the target and adjacent organs. Then use intrafraction monitoring appropriate to the platform.
Speaker 2Before drawing an optimistic target, let's make the organs at risk explicit.
Speaker 1Contour the stomach, duodenum, small bowel, and large bowel separately. Contour liver, kidneys, and spinal cord.
Speaker 2Each separately, even the bowel?
Speaker 1Yeah, a combined bowel bag can be useful for low-dose review, but it cannot replace a dedicated duodenum contour when the target sits against the duodenal sweep.
Speaker 2And which biliary and vascular landmarks? Tell us about extent and high-risk pathways.
Speaker 1You review the common bile duct or stent, portal superior mesenteric venous confluence, celiac axis, common hepatic artery, superior mesenteric artery, superior mesenteric vein, and aorta, because these structures define disease extent and high-risk pathways.
Speaker 2With those organs and landmarks visible, you choose the target definition strategy deliberately.
Speaker 1For classic five-fraction SBRT under the 2019 ASTRO framework, treat gross tumor and involve nodes with a small margin.
Speaker 2Just involve nodes?
Speaker 1Right. Elective nodes are not routinely treated. Huh.
Speaker 2So what was that smaller field strategy trying to preserve?
Speaker 1Well, that approach grew from prospective multifraction SBRT studies designed to limit gastrointestinal toxicity and minimize time away from chemotherapy.
Speaker 2But for dose-escalated treatment under the 2025 NRG consensus, you create a high-risk CTV and a low-risk CTV. The high-risk CTV contains gross tumor plus the abutting or involved vessels.
Speaker 1And the low-risk CTV?
Speaker 2The low-risk CTV addresses recurrent perivascular and neural pathways.
Speaker 1So for a head, neck, or proximal body tumor, describe where that lower risk volume begins and ends.
Speaker 2For a head, neck, or proximal body tumor, it starts about one centimeter above the celiac takeoff, and it continues inferiorly to the first jejunal branch of the superior mesenteric artery.
Speaker 1And which structures and perivascular margins belong inside that description?
Speaker 2It encompasses the pancreatic head and approximately 5 to 10 millimeters around relevant portions of the celiac axis, superior mesenteric artery and vein, common hepatic artery, and medial portal vein.
Speaker 1But that newer atlas does not mean every pancreas SBRT plan must include an elective triangle volume. It is a consensus for dose-escalated treatment and future standardization. Good.
Speaker 2That's worth saying out loud.
Speaker 1And the authors acknowledge variation in elective coverage and the absence of randomized evidence defining the best volume.
Speaker 2So what happens if we borrow a dose here, an elective field there, and constraints from somewhere else?
Speaker 1Yeah, that's the trap. The wrong move is to take the high dose from one protocol, the elective volume from another, and the constraints from a third.
Speaker 2And the pre-chemotherapy extent also matters. Tumor vessel contact may become difficult to see after response. Hmm.
Speaker 1So what do you do?
Speaker 2You review and fuse the original imaging, then decide which initial high-risk interfaces belong in the target.
Speaker 1But that reconstruction still isn't permission to expand through bowel, is it? No.
Speaker 2Do not expand indiscriminately through stomach or bowel. Reconstruct the disease pathway with the treating surgeon and radiologist.
Speaker 1Hmm. And the same anatomy-first reasoning looks different after an operation. So let's contrast post-operative treatment.
Speaker 2Postoperative chemoradiation is selective, as discussed in the prior pancreas episodes, but when it is chosen for a pancreatic head cancer, the RTOG 0848 consensus atlas uses reproducible regions of interest rather than a vague tumor bed circle.
Speaker 1Not a vague circle.
Speaker 2Good.
Speaker 1So walk me through the imaging, surgical landmarks, and vessels we reconstruct.
Speaker 2Fuse the preoperative imaging. Identify the preoperative tumor location, surgical clips, and pancreatic ojejunostomy, and margin at risk.
Speaker 1And the vessels?
Speaker 2Contour the celiac axis, proximal superior mesenteric artery, portal vein, and aorta. Then generate the atlas-defined perivascular and nodal CTV.
Speaker 1The principle is more important than memorizing an isolated expansion. Anatomy reconstructs where microscopic disease was likely to remain after a Whipple operation.
Speaker 2Oh, I like that.
Speaker 1And ASTRO recommends about 45 to 54 gray and 1.8 to 2 gray fractions with fluorouracil-based chemotherapy for selected adjuvant conventional treatment.
Speaker 2I mean, five visits would be convenient. But can adjuvant SBRT simply replace that conventional course? No.
Speaker 1Adjuvant SBRT belongs on a clinical trial or multi-institutional registry, not as a convenient five-fraction substitution. You know what?
Speaker 2Let's return to Ms. Patel. and select the NRG dose-escalated five-fraction approach for teaching purposes. A representative dual prescription is 50 gray to the high-dose volume and 33 gray to the low-dose volume.
Speaker 1And if the anatomy favors a more protracted approach, what other paired prescriptions does the consensus describe?
Speaker 2The same consensus describes 67.5 and 37.5 gray in 15 fractions. or 75 and 45 gray in 25 fractions. That's for situations where a more protracted approach better fits the anatomy and technology.
Speaker 1So just pick whichever you like?
Speaker 2No. These examples are not a menu from which dose is chosen by preference alone.
Speaker 1Right. And honestly, margins must belong to the delivery system. The NRG group suggests approximately a 3-millimeter PTV for adaptive treatment, and 5 millimeters for non-adaptive treatment, depending on motion management and intrafraction verification.
Speaker 2And how should we think about a planning risk volume around the hollow organs?
Speaker 1Outside a trial, a 1 to 5 millimeter planning risk volume around stomach, duodenum, and small bowel may be used according to technology and monitoring.
Speaker 2And when things are less certain?
Speaker 1Larger uncertainty demands a larger margin or a more conservative prescription. It does not justify pretending the uncertainty is absent.
Speaker 2So now attach the protocol label before quoting a constraint.
Speaker 1For a non-adaptive, dose-escalated five-fraction plan, the 2025 NRG Atlas suggests the following. For each of stomach, duodenum, and small bowel, D0. 5 cubic centimeters should be no more than 33 gray, and D5 cubic centimeters no more than 30 gray.
Speaker 2Okay. Keep those small volume metrics distinct, though. What does this same non-adaptive five-fraction set say for large bowel, liver, and cord?
Speaker 1For large bowel, D0. 035 cubic centimeters should be no more than 40 gray, and D5 cubic centimeters no more than 33 gray.
Speaker 2And the rest?
Speaker 1Mean liver dose should be no more than 15 gray, and spinal cord D0. 035 cubic centimeters no more than 22 gray.
Speaker 2But those numbers are not the universal pancreas constraints. They belong to a named consensus, fractionation, and non-adaptive planning context.
Speaker 1So what might differ in an institutional protocol, even if the prescription sounds kind of similar?
Speaker 2Well, an institutional protocol may use different PRVs, point volume definitions, delivery schedules, or adaptive rules. So a board answer should say the source of the constraint set before quoting it.
Speaker 1Consider a duodenum V33 limit of less than one cubic centimeter. The newer NRG table uses D 0.5 cubic centimeters, no more than 33 gray, and D 5 cubic centimeters, no more than 30 gray for duodenum, stomach, and small bowel. Similar-looking metrics are not interchangeable. Huh.
Speaker 2They sound close. What is each metric actually asking us to measure?
Speaker 1V33, less than 1 cubic centimeter, asks how much organ receives at least 33 gray. Right.
Speaker 2And the other?
Speaker 1D0. 5 cubic centimeters, no more than 33 gray, asks whether the hottest half cubic centimeter stays at or below 33 gray. So know which question your protocol asks.
Speaker 2Now, suppose the target and duodenum compete. Which priority governs the plan?
Speaker 1Holovisca safety takes priority. The NRG consensus advises that dose-escalated five-fraction treatment generally not be used with frank invasion or ulceration of stomach, duodenum, or small bowel.
Speaker 2Okay. And short of that?
Speaker 1Limited abutment does not automatically exclude five fractions.
Speaker 2But the length and degree of contact still matter, right? So what makes abutment a relative contraindication and what are our alternatives?
Speaker 1Long segment abutment, especially more than roughly three to five centimeters or wrapping more than 180 degrees, is a relative contraindication.
Speaker 2Got it. And the options?
Speaker 1Options include accepting deliberate undercoverage at the interface, using 15 or 25 fractions, lowering dose, or choosing a different local strategy.
Speaker 2So for Ms. Patel's 2-centimeter duodenal abutment without invasion, you do not reject 5 fractions from contact alone. You generate the plan and assess whether the selected constraints can be met with meaningful target coverage.
Speaker 1And if we can't achieve both meaningful coverage and those duodenal limits, what has to change?
Speaker 2If they cannot, you change the plan rather than changing the definition of acceptable bowel dose.
Speaker 1Daily changes in that relationship are where online adaptation can justify its complexity.
Speaker 2At each fraction, acquire high quality daily imaging. For adaptive treatment, contour the relevant targets and organs as visualized on the anatomy of the day.
Speaker 1Then what?
Speaker 2Then evaluate whether the scheduled plan remains acceptable on that anatomy.
Speaker 1And if today's anatomy makes it unacceptable, what has to happen on the table?
Speaker 2Right. If it does not, you perform on-table adaptive replanning with platform-specific quality checks and monitoring.
Speaker 1And how often is that?
Speaker 2The multi-institutional SMART trial adapted 93.1% of fractions, showing how frequently upper abdominal anatomy made the scheduled plan suboptimal. Wow.
Speaker 1Still, adaptation is not automatically better treatment. It requires adequate imaging... Contouring accuracy, time, physics support, quality assurance, and control of anatomy that may continue moving after the adaptation image.
Speaker 2Right, but the anatomy can still move after that image. So what do we do about that?
Speaker 1A beautifully adapted plan delivered after the stomach shifts is not robust. So recheck anatomy and use gating or tracking when available.
Speaker 2You know, let's appraise the finished plan in an order that makes those priorities visible.
Speaker 1First, verify preparation and registration. Second, inspect luminal organ maximum and small volume dose.
Speaker 2Huh, in that order.
Speaker 1Yeah. Third, inspect target coverage, especially the tumor vessel interface and any deliberate underdosed region.
Speaker 2Preparation, bowel dose, coverage. So where do your eyes go next?
Speaker 1Fourth, locate the hotspot inside tumor and away from bowel. Fifth, inspect intermediate dose spill, liver, kidneys.
Speaker 2And cord. Mm-hmm. Keep going.
Speaker 1Sixth, Test whether the plan remains credible under respiratory and day-to-day variation.
Speaker 2And beyond the number on the prescription, what dose do we need to document?
Speaker 1Finally, document what dose the target actually receives. I mean, in pancreas dose escalation, the prescription may overstate delivered tumor coverage because bowel-sparing forces undercoverage.
Speaker 2And honestly, supportive care is part of safe delivery. Give prophylactic antiemetics. Acid-reducing medication is reasonable in selected patients, and monitor acute gastrointestinal toxicity and clinically relevant symptoms during treatment.
Speaker 1But can medication compensate for an unsafe duodenal dose?
Speaker 2No, medication does not make an unsafe duodenal dose safe.
Speaker 1If the patient asks why five treatments can take longer than expected each day, a useful version is the pancreas sits beside the stomach and bowel, and those organs move and fill differently every day. We image you before treatment and may rebuild the plan so the high dose follows the tumor while avoiding the bowel as it appears that day. The extra time is part of making a short course precise. If the anatomy is not safe, we change the plan rather than forcing the scheduled dose.
Speaker 2Those choices lead directly to the three oral board traps.
Speaker 1Trap 1. Quoting a pancreas constraint without naming the fractionation, organ definition, volumetric, and protocol. V, 33 less than 1 cubic centimeter, and D, 0.5 cubic centimeters, no more than 33 gray, are not identical rules.
Speaker 2Trap 2. Treating a biliary stent or bony anatomy as a perfect tumor surrogate. Prefer fiducials and volumetric soft tissue assessment. Compensate when the surrogate is less reliable.
Speaker 1Trap 3. Forcing 50 gray in 5 fractions through frank duodenal invasion because the BED is attractive. Protect hollow viscous and choose undercoverage, de-escalation, more fractions, or another strategy.
Speaker 2Here are the 5 board pearls to carry into plan review.
Speaker 1Pearl 1. The indication, target atlas, fractionation, constraints, margins, and image guidance method must come from one coherent treatment package.
Speaker 2Pearl 2. Measure respiratory motion. Do not infer it from tumor location or a single CT phase.
Speaker 1Pearl 3. For CT-guided SBRT, fiducials plus volumetric imaging are preferred because bone and stents are imperfect surrogates.
Speaker 2Pearl 4. The 2025 NRG Dose Escalation Atlas uses high-risk tumor and vessel coverage plus a lower-dose perivascular volume, but randomized proof for that strategy is lacking.
Speaker 1Pearl 5. Online adaptation recalculates and may re-optimize the plan on daily anatomy. Ordinary repositioning is image guidance, not adaptation.
Speaker 2Let's put the constraints and motion logic to work in Board Blitz. Case 1. A free-breathing 4-dimensional CT shows 9 mm of pancreatic tumor excursion. Can you use a 3 mm PTV because daily cone beam CT is available?
Speaker 1Not without a motion solution. Daily imaging corrects setup at one time point. It does not erase respiration or intrafraction drift. Use breath hold, gating, tracking, compression, or an ITV-based strategy. Then select a margin supported by that system.
Speaker 2Case 2. A non-adaptive NRG-style 5-fraction plan has duodenum D0. 5 cubic centimeters of 34 gray and D5 cubic centimeters of 29 gray. Does it meet the example constraints?
Speaker 1No. The D5 cubic centimeter metric meets the suggested limit of 30 gray, but the hottest half cubic centimeter exceeds the 33 gray limit. Reoptimize or modify the treatment package. Do not average the two metrics into a pass.
Speaker 2Case 3. The stomach is farther from the target today than its simulation, but the duodenum is closer. The scheduled plan violates the duodenal limit. Is shifting the patient enough to call the fraction adapted?
Speaker 1No. Repositioning is image guidance. Online adaptation requires recalculation on the daily anatomy and, when indicated, recontouring and reoptimization, followed by the required quality checks. If a safe, adapted plan cannot be produced, do not deliver the scheduled plan.
Speaker 2So let's bring the final takeaways back to the coherent treatment package.
Speaker 1Start with the named treatment package, not an isolated prescription. Use contrast and thin-slice imaging, measure motion, and align simulation with delivery.
Speaker 2Simulation, matching, delivery. Yeah.
Speaker 1Prefer fiducial-assisted volumetric guidance or direct soft tissue visualization. And keep postoperative, gross disease, SBRT, and dose-escalated dual-volume targets distinct.
Speaker 2And, I mean, even with an attractive BED, what keeps the plan honest?
Speaker 1Quote constraints only with their protocol and fractionation. Protect stomach, duodenum, and bowel before chasing coverage or BED.
Speaker 2Bowel before BED.
Speaker 1Nice. And adaptation is a real replanning workflow, and its value depends on imaging, contouring, quality assurance, and intrafraction control.
Speaker 2In the next episode, we will begin hepatocellular carcinoma with diagnosis, liver function, staging, transplant, and liver-directed pathways, and multidisciplinary treatment selection.
Speaker 1Get show notes and complete practice oral boards at radonksmartlearn.com and subscribe for our next episode. Thanks for tuning in.
Test your reasoning in a comprehensive breast oral board. Pause at each question, commit to your answer and compare it with the discussion. Chapters00:00 Opening and the first patient's case 02:04 First patient: surgery...
Practice reading breast trial endpoints and explaining absolute benefit and uncertainty to a patient. Chapters00:00 Opening and two recall questions 01:46 Her case, three questions and the board answer 04:00 Endpoints:...
Explore how endocrine therapy, menopausal symptoms and access to care shape the patient’s experience after initial treatment. Chapters00:00 Opening and two recall questions 02:31 Her case and the board answer 05:07 Why...
Plan the transition from active treatment to surveillance, including follow-up visits, symptoms to evaluate and responsibilities at the survivorship handoff. Chapters00:00 Opening and two recall questions 02:23 Her case...
Review the presentation and management questions raised by Paget disease, phyllodes tumors and other uncommon breast tumors. Chapters00:00 Opening and two recall questions 01:22 Her case and the board answer 02:41 What...