Skip to content
PodSubs
ShowsPeopleGuestsJobsNewsEvents
More
BlogPodCred
Menu
ShowsPeopleGuestsJobsNewsEventsBlogPodCredNetworksSign in
Join nowSign in
  • Shows
  • People
  • Jobs
  • News
  • More
    • Guests
    • Events
    • Blog
    • PodCred
    • Networks
    Join nowSign in

RadOnc Smart Review

RadOnc Smart Review artwork

Episode 26: Workshop, chest wall, reconstruction, and bolus planning

Nov 19, 202629 minAudioEpisode 26
ShareXLinkedInFacebookWhatsAppEmail

Practice chest wall planning in the setting of reconstruction, including target coverage, organ protection and the decision about bolus. Chapters00:00 Opening, the planning scanner and two recall questions 01:58 Her case, her targets and the named goal set 06:16 Simulation and setup 09:10 Contours: where the target ends over a reconstruction 14:07 Bolus: decide, then verify 17:46 Technique, protons and the metal port 20:29 Plan review against the named set 23:13 Accept, revise or escalate 25:44 Planning traps and Board Blitz 27:27 Patient explanation, back to the scanner and closeThe patients in this episode are invented for teaching. For education only. This is not medical advice. Notes and practice oral boards: radoncsmartlearn.com

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

Avery: Welcome back to Rad Onc Smart Review, Breast Oncology. Eden: This is episode twenty-six, Workshop: chest wall, reconstruction, and bolus planning. Avery: So picture this. You have our patient lying on your planning scanner. She has already had chemotherapy. She has undergone a mastectomy, and right now, sitting on her chest wall is a temporary tissue expander. Eden: Yeah, and it has a solid metal port built right into it. Avery: So where exactly does your target end when a device sits right under her skin? Does that skin need bolus to bring the dose to the surface?

Eden: And when you are sitting in the dark room reviewing the dose volume histogram, which specific numbers decide whether you can sign off on that plan? Avery: Well, today we are going to plan her from the initial scan all the way to the final review, accepting, revising, or escalating at each step. Eden: So I want you to think about these next two recall questions. First, consider her initial presentation. She presented with cN2a disease. Eden: If her nodes had cleared completely after her neoadjuvant chemotherapy, meaning a pathologic complete response, could radiation after her mastectomy be left out?

Pause and answer. Avery: No. Avery: For initial cT4 or cN2 to N3 disease treated with neoadjuvant systemic therapy, the twenty twenty-five Astro, Asco, and SSO guideline strongly recommends post-mastectomy radiation regardless of the pathologic response. Eden: Right. And that is a strong recommendation based on moderate quality evidence. Now, the NCCN takes a different angle in its phrasing as it bases adjuvant radiation on the maximal disease stage. Avery: The highest stage she reached. Eden: Right. And that brings us to the second

question. When we map out her nodes, which two atlas families define the nodal target volumes? Pause and answer. Avery: Well, the atlases are the RTOG atlas, which the twenty twenty-five guideline names, and the twenty fifteen Estro consensus, which NCCN cites. Eden: And having two distinct atlas families isn't just academic trivia. It alters where you draw your lines on the screen, which we will see later. Avery: So let's recap her baseline. Last time, our forty-four-year-old patient chose her reconstruction route, an expander with a metal port placed at the time of her mastectomy. Eden: Right, with radiation delivered directly to that

expander and then the permanent implant swapping in at least six months later. Avery: Exactly. So her baseline diagnosis was left cT3 N2a breast cancer, estrogen receptor positive and HER2 negative. She had residual disease after her neoadjuvant chemotherapy. Eden: And the surgical facts we are working with today shape every contouring and planning decision that follows. At her mastectomy, the surgeon performed a level one and two axillary dissection, which removed fourteen nodes.

Avery: And two of those fourteen nodes held residual cancer. Eden: Right. However, there was no extranodal extension, and no tumor deposits were found in the axillary fat. Her surgical margins are negative. Eden: The skin itself is normal, and pathology confirmed there is no dermal lymphatic invasion and no extensive lymphovascular invasion. Avery: So based on those surgical facts, her targets are already settled. Today, we plan them rather than argue whether they should be treated. Avery: We are targeting the

reconstructed chest wall with the scar, the supraclavicular nodes, the level three nodes, and the internal mammary nodes. Eden: And that inclusion of the internal mammary nodes is an individual decision based on her overall nodal burden. Avery: Right. But I want you to look closely at what is missing from that list. The dissected levels one and two of the axilla are not on it. Eden: When a surgeon removes fourteen nodes and pathology shows clear axillary fat with no extranodal extension, the dissected levels one and two are not routinely targeted.

Avery: Okay, so let's talk about the schedule. We are looking at forty-two point five six gray in sixteen fractions. Eden: Right. And with a reconstruction in play, the guideline recommends moderate hypofractionation, which it prefers, or conventional fractionation. Avery: Yeah, and this schedule, forty-two point five six gray in sixteen fractions, is also the shorter arm of RT Charm, the Alliance trial. Eden: And the RT Charm protocol allowed a fluid-filled expander and required internal mammary treatment. Avery: And her initial nodal stage was not an exclusion for RT Charm. Eden: Right.

The trial did exclude T4 disease, N3 disease, and involved internal mammary nodes at presentation, but cN2a, which she had, was permitted. Avery: So what does this all mean for our goal tables? When you are staring at the dose-volume histogram, which set of constraints decides if this plan passes or fails? Eden: Well, we use the twenty twenty-five Astro guideline, specifically relying on the column for fifteen to sixteen fractions. Avery: Now, you might wonder why not just use the trial protocol's constraints. Avery: The rule is that a

guideline ranks above a trial protocol, and where the trial protocols differed from one another, the guideline took the more conservative value. Eden: Yeah, but it is important to name the limits of that guideline too. When you read those tables, several of the hypofractionated goals are extrapolated from conventional longer schedules. Avery: Right. Eden: Exactly. And because of that, the goals may not be achievable for every plan. However, for our contours, we use the protocol structures. Avery: Yeah, the reason is that the protocol adapts the RTOG atlas, and the guideline's own

tables cite this trial among their sources. All right, let's put it all together. Avery: Give me the sixty-second board answer: her targets and schedule, the set you judge the plan against, and whether she gets bolus. Pause and draft it. Eden: A forty-four-year-old with left cT3 N2a, ER positive, HER2 negative breast cancer, residual disease after neoadjuvant chemotherapy, and a tissue expander. Eden: Radiation goes to the reconstructed chest wall with the scar and to the supraclavicular, level three and internal mammary nodes. The dissected levels one and two are not routinely targeted. Eden: Forty-two point five six

gray in sixteen fractions, in breath hold if it lowers heart and lung dose. I judge the plan against the twenty twenty-five Astro goals for that schedule. Eden: The acceptable floor is ninety percent of each target getting ninety percent of the dose, or eighty percent for the internal mammary nodes. Eden: A mean heart dose of four gray or less, ideally two point four, and no more than thirty-five percent of the ipsilateral lung getting seventeen gray. No bolus, because she has no skin risk finding. Eden: A plan that misses an acceptable goal is revised, or kept with a documented physician decision. Avery: Now we move into the actual workshop. Step one, simulation.

We have our patient on the table. Question one, what has to be true about the expander before you simulate? Pause and answer. Eden: It is at the fill it will keep for the whole course, and it holds fluid, not air. The RT Charm protocol counts the expander as part of the target, and a target in air cannot receive the prescription dose. Avery: Right. Eden: Its volume may not change between simulation and the last fraction without a new simulation and plan. Eden: Also, the amount of fill is the treating physician's

call, and there is no consensus on whether the expander should be deflated. Avery: So let's talk about the setup mechanics to capture her anatomy. She lies supine, flat on her back, as the protocol requires. Eden: And we take radiopaque wire and outline the mastectomy scar and any clinically relevant drain sites. Avery: Right. The NCCN includes those drain sites in the target. We mark the chest wall outline from at least two o'clock to ten o'clock to give ourselves physical boundaries. Eden: Then we scan her from the

jaw or above using CT slices thinner than five millimeters. And locating and marking the metal port on the skin is department practice too, so we know where that high-density object lives. Avery: And because she is left-sided, we also scan her in breath hold. Eden: Yes, deep inspiration breath hold. We use it when it lowers the heart and lung dose compared with free breathing. Avery: Think about the anatomy. When a patient takes a deep breath and holds it, the lungs inflate and push the heart down and away from the chest wall. Eden: Right, which requires real-time monitoring and

image-guided verification to ensure she takes the same size breath every time. Surface guidance can be used to watch the hold as long as it falls within your clinic's tolerances. Avery: However, the guideline finds the data lacking for using surface guidance alone in daily post-mastectomy treatment. Eden: Right. So image-guided verification stays part of the breath hold. Avery: Okay. Now, what if we throw a wrench in the setup? What if she had a pacemaker or an implantable cardioverter defibrillator? Eden: The AAPM task group report on cardiac devices sets the

steps for that. First, you locate the device. Second, you estimate its cumulative dose from your planned beams. Eden: Third, you ask cardiology whether she is pacing dependent. Avery: Yeah, those two facts, the estimated dose and her dependency, set her risk category. From a physics standpoint, you must avoid using photons above ten megavolts, and you must avoid protons. Eden: Because photon beams above ten megavolts can trigger photonuclear reactions, generating stray neutrons, right? Avery: Exactly. Neutrons are heavy, uncharged

particles that scatter unpredictably and can interfere with the electronics of a cardiac device. Protons bring neutrons too. Eden: And finally, you must measure the device dose on the first fraction of treatment if it lies within ten centimeters of the treatment area. Avery: Right. Now, step two, contours and the implant. Before we can tell the computer where to deliver the dose, we have to map the terrain. Eden: Because the chest wall is not a single structure, it has distinct anatomical layers. You have the skin, the subcutaneous tissue, the pectoralis muscles, and then the

deep boundary of the ribs and intercostal muscles. Avery: Exactly. By the protocol, the chest wall clinical target volume, or CTV, runs from the skin down to no deeper than the front of the ribs, leaving out the heart and lung tissue. Eden: And the scar CTV is defined as the physical scar itself plus a one centimeter margin. Avery: Right. And the planning target volume, or PTV, adds an expansion of five to seven millimeters around the CTV to account for daily setup errors, typically guided by your department's practice.

Eden: An evaluation structure is then created in the software to trim the first five millimeters under the skin. It stops at the back of the ribs. Avery: Right. This drops the buildup region from the dose volume histogram. The chest wall dose goals are read on this evaluation structure, and it is not used to shape the radiation beams. Eden: Right, the buildup region. If the computer includes the cold spot at the surface in its evaluation, it skews your data, making the plan look underdosed. Avery: So the actual target reaches the skin. We are still aiming radiation there, but the crop is for

evaluation only. Eden: However, we must be aware that the atlases differ. The RTOG atlas runs the chest wall down to the rib-pleural interface, meaning the pectoralis muscles and the ribs themselves are inside the target volume. Avery: The twenty fifteen Estro consensus is different. It stops five millimeters under the skin and leaves the pectoralis major and the ribs out of the target unless they were invaded by the tumor. Eden: But that consensus was written for early stage disease. It asks the physician for individual adaptation and delineation in locally advanced cases like hers.

Avery: And if we look closely at the Estro-ACROP authors, they issue a specific warning. They advise against using that five millimeter evaluation crop over an implant. Eden: Let's think about the mechanics of a reconstructed breast. You have a thin skin envelope stretched over a saline-filled expander. The lymphatic channels under the skin can lie close to the surface. Avery: Right. In a natural breast, you have a buffer of subcutaneous fat. In a reconstructed breast, that skin envelope can be thin. Eden: So a five millimeter crop can leave that lymphatic layer

out of the evaluation, and a thin envelope can make the crop impossible. Avery: Because of these differences in philosophy, you must state which atlas your plan follows. That brings us to question two. We are drawing our borders. Is the implant inside your CTV, and which document answers that? Avery: Pause and answer. Eden: For her locally advanced disease, yes. The trial protocol puts expanders, implants, and autologous flaps inside the chest wall CTV.

Avery: Now, the Estro-ACROP guideline, which again was written for early disease, leaves the implant itself out of the target, but it widens the target behind the implant when adverse factors are present, such as residual disease after chemotherapy. Eden: Right. For locally advanced disease, it asks for individual adaptation. And when staging is unclear, it includes the whole mastectomy site along with the implant. Avery: Because she has residual disease, the conservative clinical error is to not shrink

the target, so her CTV covers the entire reconstructed chest wall with the expander included. Eden: So the expander is in the target. Now for the regional nodes as defined by the protocol. Eden: The undissected axilla is typically defined as the high level two and level three nodes, and its CTV starts at the top of the surgical dissection bed. Avery: The protocol does add the full axilla when fewer than six nodes were removed. But remember, that is a specific trial definition, and our patient had fourteen nodes removed. Avery: The guideline applies

axillary goals only to the targeted axilla after a completion dissection. Eden: As for the internal mammary CTV, it covers the first three intercostal spaces alongside the sternum, and its PTV adds five millimeters medially and laterally. Avery: You must ensure there is no expansion into the lung tissue, because we do not want to target healthy lung. Eden: And while we are contouring targets, we cannot forget the organs at risk. The protocol requires you to contour both lungs, the contralateral breast, the heart, and the thyroid. Avery: The guideline sets no specific numerical constraint

for some vulnerable cardiac substructures, such as the left anterior descending artery, or LAD, but it still advises contouring them. Eden: So to be thorough, we outline the LAD, the left ventricle, the brachial plexus, and the esophagus. Avery: We also have to draw a contour around that metallic port inside the expander, and not just draw it, but give it a material assignment that physics has verified for your treatment planning system. Eden: We will get into why that matters for the photon dose calculation a bit later. Avery: Right.

But first, let's move to step three, bolus and skin risk. This is an area of debate. Question three, would you bolus her? And what single finding would change your answer? Pause and answer. Eden: No. For cT1 to T3 disease, Astro does not recommend routine bolus, which is a strong recommendation based on moderate quality evidence, and NCCN agrees. Avery: Yeah. An international consensus panel on early breast cancer rejected routine bolus for post-mastectomy radiation, regardless of whether reconstruction is present or absent. Eden: Any one skin risk finding

would change the answer. Skin involvement by the tumor, a positive superficial surgical margin, dermal lymphatic invasion, or extensive lymphovascular invasion. Avery: The evidence behind that no routine bolus rule is quite thin when you dig into it. Eden: Yeah. A pooled review found similar crude local recurrence rates both with and without bolus, but it found more severe acute skin reactions when bolus was used. Avery: Right. A large cohort of women without skin involvement found that adding bolus was not linked with better local control after

statistical adjustment. These are pooled, retrospective, and cohort data. Eden: This is not randomized level one proof either way. Avery: And when we look at placing bolus over a reconstruction specifically, the stakes are even higher. Reconstruction in and of itself is not a bolus indication. Eden: We know that bolus raises acute skin toxicity in general. Skin and wound healing problems are linked with reconstruction complications. Avery: Over a reconstruction, no gain from bolus has been shown. Eden: In fact, in Danish test plans, standard six megavolt photons gave full skin dose over most reconstructed breasts

without any bolus at all. Avery: Okay, now let's change one critical fact about our patient. The final pathology report comes back, and it shows dermal lymphatic invasion. What happens to your bolus strategy? Pause and reason it through. Eden: Bolus is now recommended, not just considered. Astro recommends it for dermal lymphatic invasion, which is a strong recommendation that rests on expert opinion, and NCCN says bolus should be used. Avery: The presence of the

reconstruction does not cancel out that recommendation. However, it does mean that the skin envelope and the reconstruction carry more risk, so the bolus must be planned and applied with care. Eden: Let's explore that tension for a second. In the general case, without bolus, because of the buildup region of megavoltage photons we discussed earlier, the surface dose may reach only seventy to eighty percent of the prescription. Avery: We are trying to protect a vulnerable, reconstructed skin envelope. But dermal lymphatic invasion means the cancer is in the lymphatic channels of the dermis

itself. Eden: To apply the bolus, you place it on the patient at the time of simulation, so it is in the planning CT and the dose calculation. Avery: A thickness of three to five millimeters of tissue equivalent material is usually enough to pull that surface dose up. Avery: You use it daily for the whole course of treatment, and it must be shaped to cut any air gaps over the curve of the reconstruction. Eden: Air gaps are the enemy of bolus. If the bolus does not conform to that curve, you can lose some of the dose buildup effect. Avery: In those cases, you have

to consider using a 3D-printed bolus or another conformal bolus. Eden: We know clinically that daily bolus brings more skin toxicity than applying bolus on alternate days, and the consensus panel answers that by keeping bolus for high skin risk cases like this one. Avery: Once you implement it, you must check what the skin gets. Avery: You use in vivo dosimetry like optically stimulated luminescent dosimeters directly on the skin during the first fraction, relying on your clinic's specific dosimeters and established tolerances to verify

the computer's prediction. Eden: Okay, we have defined our targets, we have drawn our contours, and we have our bolus strategy locked in. We now move to steps four and five, technique, plan review, and the drill. Avery: For technique selection, we start with CT-based 3D conformal planning, which Astro strongly recommends as the baseline standard. Eden: When we say 3D conformal, we are talking about partially wide tangential beams that include the internal mammary nodes, plus a matched supraclavicular field. Avery: Electron beam options for

the chest wall do exist in the guideline and the protocol. Avery: But if 3D conformal cannot meet the coverage goals or the organ at risk limits, Astro recommends stepping up to intensity-modulated radiation therapy, or IMRT, including its rotational form, volumetric modulated arc therapy, or VMAT. Eden: It is vital to note the trade-offs here. While IMRT and VMAT can solve high dose conformity issues, bending the dose around the heart, they do so at a cost. Avery: Yeah. They use many beam angles, which

may raise the low dose exposure to surrounding healthy tissue, bathing the contralateral breast and the healthy lung in a low dose of radiation. Eden: Because of that complex delivery and steep dose gradients, they require daily imaging and regular 3D volumetric checks, such as cone-beam CT, to ensure the patient's anatomy hasn't shifted. Avery: And what about protons? Eden: Because of their physical properties, the Bragg peak, they deposit most of their dose at a chosen depth and little beyond it, which can lower the dose to the heart. Avery: But the guideline calls proton therapy under

investigation, and the randomized comparison trial has not yet reported its main cardiac endpoint. Eden: The particle therapy consensus lists protons as an option after immediate reconstruction, but it does so at low levels of evidence, and trial enrollment should be considered. Avery: Furthermore, when dealing with a tissue expander, proton use is limited and selected. Remember that metal port? The high density of the metal port distorts the planning CT through artifact. Avery: This creates uncertainties in calculating the proton stopping power. If the computer calculates the

density wrong, the proton beam might stop short, underdosing the tissue behind it. Eden: It complicates the dose calculation so much that our patient is planned with photons. Avery: And make no mistake, that metal port matters for photons, too. The RT Charm protocol requires heterogeneity correction in the planning system. Eden: In one planning study, ignoring the density of the port made the dose coverage behind the port look better on the screen than it actually was. Avery: The dense metal was physically attenuating the photon beam, absorbing the radiation, but the computer didn't know it, so it painted a

falsely optimistic dose map. Eden: So the port must get its verified material assignment in the system, so the physics engine can account for the attenuation. Avery: Now, let's walk through the dose-volume histogram, or DVH, in order. We are checking the plan against the guideline-specific goals for this three-week hypofractionated schedule. Eden: We look at the targets first. For the chest wall, the supraclavicular nodes, and the targeted axilla, the ideal metric is ninety-five percent of the PTV volume getting ninety-five percent of the prescribed dose.

Avery: The acceptable floor is ninety percent of the volume getting ninety percent of the dose. Eden: For the internal mammary nodes, the ideal is ninety-five percent of the volume getting ninety percent of the dose, and the acceptable floor drops to ninety percent of the volume getting eighty percent of the dose. Avery: Then we evaluate the chest wall hotspot. We are not just looking for a broad area of high dose, we are looking for the hottest tenth of a cubic centimeter. Eden: Having that zero point one cc volume at one hundred seven

percent of the prescription dose or less is ideal, and up to one hundred fifteen percent is considered acceptable. Avery: Moving from the targets to the organs at risk, for a left-sided plan like hers, the mean heart dose is ideal at two point four gray or less, and acceptable at four gray or less. Eden: But regardless of the number, it must be driven as low as reasonably achievable. Eden: For the ipsilateral lung, the lung on the left side, the volume getting seventeen gray is ideal at twenty-five percent or less and acceptable at

thirty-five percent. Avery: After we clear those primary hurdles, we check the contralateral breast and the right lung, followed by those substructures we drew earlier, like the LAD, that do not have firm numerical limits. Eden: For context, the RT Charm trial's own tiers were actually looser. The trial accepted a mean heart dose up to five gray, whereas the guideline we are following today accepts only four gray for this exact schedule. Avery: So we are strict about this heart limit because

decades-old data show that in women treated in the past, major coronary events rose by about seven percent for each gray of mean heart dose. Eden: And a safe threshold, a number below which there is zero risk, has never been shown. Avery: Furthermore, we know that the mean heart dose does not perfectly track the dose to specific critical substructures like the LAD or the left ventricle. Eden: You could have a low mean heart dose but still have a localized hotspot directly over a major coronary artery.

Avery: In planning studies, it was the inclusion of the internal mammary nodes, not the presence of the reconstruction itself, that drove up the dose to the heart and the lung. Eden: So if achieving that internal mammary coverage costs you heart dose, that trade-off must be documented in the patient's chart, not just accepted silently. Avery: Let's run the drill. We are sitting in the dark room, and we have plan A, plan B, and plan C in front of us. Plan A is a 3D conformal plan utilizing deep inspiration breath hold. Eden: We look at the DVH, and the internal mammary coverage falls short in the top

interspaces. Less than ninety percent of that PTV is getting eighty percent of the dose. Avery: It is below the guideline's acceptable goal. The action here is revise. Eden: So we send a clear, concise message to the dosimetrist. It reads, "Plan A is short on internal mammary coverage in the top interspaces, below the guideline's acceptable line. Eden: Can you try a hybrid or VMAT version, same coverage goals and same heart limit? Thanks." Avery: A few hours later, plan B comes back as that hybrid version, mixing tangents with small modulated arcs.

We walk the DVH again. Eden: Every target meets at least its acceptable goal. The mean heart dose is four gray or less, and the left lung volume getting seventeen gray is thirty-five percent or less. Avery: The action is accept it and document each metric that meets the acceptable threshold but falls short of ideal. Avery: Had its mean heart dose been above four gray with no documented reason, plan B would fail, even though the trial's tier would allow it. Eden: Then we review plan C. Plan C was calculated without

the port's material density assignment. Avery: The region directly behind the port looks fully covered on the computer screen. The action here is escalate to physics for recalculation and verification of the material properties. Eden: Question four. What would make you escalate to physics rather than asking dosimetry to revise? Pause and answer. Avery: Escalate when the dose calculation itself cannot be trusted, or when the fix is outside the planner's control, as with plan C and the missing material assignment. Eden: Revise when the calculation is physically sound,

but a clinical goal simply fails to be met, as with plan A's short internal mammary coverage. Avery: And some changes during a patient's course mean going all the way back to square one, a new simulation and an entirely new plan. Eden: A change in the expander fluid volume is a protocol rule that demands a replan. But there are other changes. Eden: Swelling from a postoperative seroma or an infection, significant patient weight change, setup drift beyond your clinic's tolerance on cone-beam CT or surface

imaging. Avery: And bolus that once fit snugly but no longer fits flush against the skin. Those are all calls of clinical judgment against your department's tolerances. Eden: Exactly. Avery: So let's look at the three planning traps. Trap one, quoting a constraint without its source and schedule, or passing a plan on a trial's looser tier when it fails the guideline's goal. Avery: The same trap applies to borrowing the Fast-Forward whole breast or chest wall set for a regional nodal plan. That set has no nodal goals, and even its nodal substudy set had no internal mammary target

constraints. Eden: Trap two. Avery: Adding bolus over a reconstruction with no listed indication. The reconstruction itself is not an indication, and over a reconstruction, bolus has shown no gain. Eden: Trap three. Avery: Accepting a dose distribution near the metal port without a verified material assignment, or treating the patient after the expander fill has changed without initiating a new simulation and plan. Eden: Now for the Board Blitz. Two quick cases. Answer before we do. Avery: Case one, a woman with cT3 N1 disease and normal skin

has a mastectomy with clear margins, no dermal lymphatic invasion, no extensive lymphovascular invasion, and no reconstruction. Avery: The resident wants to add bolus to the plan because the tumor was large. Do you agree? Pause. Eden: No. Size is not a skin finding, and routine bolus is not recommended for cT1 to T3 disease. Bolus is kept for a skin-risk finding or inflammatory disease, and she has neither of those. Avery: Right. Case two, a left-sided post-mastectomy plan includes the internal mammary nodes, and no photon plan meets the heart

goal without losing that node coverage. A colleague says protons are now standard. Avery: What do you say? Pause. Eden: Protons can lower heart dose, but they remain under investigation, and the randomized comparison has not yet reported its main cardiac endpoint. They are an option to weigh case by case, not a standard. Avery: Finally, we have to explain all of this to the person sitting across from us. Eden: Yeah. If our patient asks why she has to hold her breath during treatment, try this. Avery: Your cancer was on the left side, close to your heart. Holding a deep breath during

each treatment can lower the radiation dose to your heart and lungs. Avery: We test it at your planning scan and use it if it lowers that dose for you, and we watch each breath hold during treatment. Eden: So, back to the scanner. Her target runs all the way to the skin with the expander inside, and her skin needs no bolus, because she has no skin risk finding. Avery: Each plan is accepted, revised, or escalated, with the reason written down in the chart. Eden: In the next episode, Episode twenty-seven, Late

effects, lymphedema, and rehabilitation. Two years after her radiation, her arm feels heavy by evening and her reconstructed breast feels firm. Avery: Get show notes and complete practice oral boards at Rad Onc Smart Learn dot com, and subscribe for our next episode. Thanks for tuning in!

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Episode 48: Comprehensive breast oral boards

    Nov 19, 202624 minAudio

    Test your reasoning in a comprehensive breast oral board. Pause at each question, commit to your answer and compare it with the discussion. Chapters00:00 Opening and the first patient's case 02:04 First patient: surgery...

    Credit the people on this episode

  2. Episode 47: Reading breast trials and explaining benefit

    Nov 19, 202636 minAudio

    Practice reading breast trial endpoints and explaining absolute benefit and uncertainty to a patient. Chapters00:00 Opening and two recall questions 01:46 Her case, three questions and the board answer 04:00 Endpoints:...

    Credit the people on this episode

  3. Episode 46: Living with treatment: endocrine therapy, menopause, and access

    Nov 19, 202635 minAudio

    Explore how endocrine therapy, menopausal symptoms and access to care shape the patient’s experience after initial treatment. Chapters00:00 Opening and two recall questions 02:31 Her case and the board answer 05:07 Why...

    Credit the people on this episode

  4. Episode 45: Follow-up, surveillance, and the survivorship handoff

    Nov 19, 202628 minAudio

    Plan the transition from active treatment to surveillance, including follow-up visits, symptoms to evaluate and responsibilities at the survivorship handoff. Chapters00:00 Opening and two recall questions 02:23 Her case...

    Credit the people on this episode

  5. Episode 44: Paget disease, phyllodes, and other uncommon breast tumors

    Nov 19, 202636 minAudio

    Review the presentation and management questions raised by Paget disease, phyllodes tumors and other uncommon breast tumors. Chapters00:00 Opening and two recall questions 01:22 Her case and the board answer 02:41 What...

    Credit the people on this episode