If You Spec Lighting, These 4 Numbers Don't Tell The Whole Truth.

Nov 3, 20261 hr 6 minAudio
ShareXLinkedInFacebookWhatsAppEmail

What happens when two lighting engineers with 30+ years of designing products and reading spec sheets reveal why the four numbers everyone relies on (CRI, CCT, IP ratings, and lumen maintenance) don’t tell the whole truth about how light performs in a space? In this episode of LytePOD, host Sam Koerbel sits down with Jeff Quinlan and Vince for an unfiltered conversation about what spec sheets tell you, what they hide, and why the industry’s metrics were built for a different era, a different light source, and a different set of problems. Jeff and Vince explain why CRI averages hundreds of wavelengths into one number. They also cover why metal halide and LED can share a CRI and look nothing alike, and why the CIE itself has said TM30 is more accurate. And they argue that the best measure of lighting quality isn’t on the spec sheet at all. It’s whether the space feels right. 💡 Key topics explored: Why spectrum matters most, and is the hardest thing to put on a spec sheet How CRI was built in 1962 for fluorescent lamps using eight pastel swatches Fidelity vs. gamut in TM30, and how both give designers control Why the same CCT can look different above or below the black body curve How thermal expansion stresses exterior products every single day Why IP ratings cover water, not steam or condensation Why sealed LEDs can fail in weeks from color shift and lumen loss Why lumen maintenance is extrapolation, not decades of real-world testing Why 99 CRI is overkill: above 95, you trade efficacy for a difference no one can see Why experienced designers trust brands over spec sheets Where AI and circadian, full-spectrum lighting fit next Whether you’re a designer frustrated by products that don’t perform as promised, a manufacturer looking to communicate quality beyond four numbers, or anyone curious why lighting still feels like guesswork despite all the data, this is an honest look at the metrics, the gaps, and the future of evaluating light. Listen now to discover why great lighting isn't about hitting numbers - it's about understanding what those numbers can't tell you. ❤️ Big appreciation for the partners who support this work and trust the vision. They believe in thoughtful conversations, strong community, and letting designers' voices lead. Grateful to build this together. 1️⃣ Peerless - https://watch.lytei.com/peerless 2️⃣ Kelvix - https://watch.lytei.com/Kelvix 3️⃣ LEDflex - https://watch.lytei.com/LEDFLEX 4️⃣ Diode LED - https://watch.lytei.com/diode 5️⃣ Targetti USA - 00:00 Opening: You're Never Staring at a Light Going, Oh Wow, That's 80 CRI 01:23 Sponsor Spotlight: Peerless, Kelvix, Ledflex, Diode LED, and Targetti USA 02:27 What You Can't Put on a Spec Sheet: The Spectrum Problem 05:34 Thermal Expansion: The Invisible Force Breaking Your Fixtures 07:26 CRI: The Metric We're Stuck With - And Why It's Broken 09:58 Same CRI, Different Light: Why 70 Doesn't Equal 70 16:27 The CIE Says Stop Using CRI - So Why Haven't We? 17:41 TM30: Two Numbers Instead of One - Is That Too Much to Ask? 26:03 All My Homies Hate CRI: Who Has to Lead the Change? 27:26 Sponsor Spotlight: Kelvix, Ledflex, and Diode LED 29:43 CCT: One Number, Infinite Variations - And Your Mom Understands It 33:34 The Black Body Curve: Above It or Below It, You'll See the Difference 35:16 The Cheap 3500K vs. The Good 3500K: What You're Not Being Told 43:17 IP Ratings: Protecting Against Water Doesn't Mean Protecting Against Steam 49:08 Lumen Maintenance: A Million-Hour Promise Based on Math, Not Reality 56:07 The Bottom of the Ladder vs. The Top: Who Needs Which Numbers? 59:35 The 99 CRI Trap: When Higher Numbers Stop Meaning Better Design 1:01:11 Circadian Lighting: The Future Metric That Doesn't Exist Yet 1:05:41 The Tyranny of Data: When Too Many Numbers Get in the Way

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show. Tap a time to play from there.

You're never staring straight at a light going, oh wow, that's 80 CRI. Even a metal halite can have a CRI of 70 and a LED can have a CRI of 70. And if you've ever seen those things side by side in an application, there is absolutely zero comparison. Jeff Quinlan has engineered lighting for over 30 years and vents make sure everything that needs to be in a product is there. I asked them which numbers on the spec sheets are actually telling you the whole truth. It's what the light emits. It's not how it makes the space feel.

The CIA, the body that created the CRI test published a thing that says we should get off of this because TM30 is more accurate. We're going to have CRI for a long time, not because it's a good metric that represents what we need, because it's the metric we've had for a long time and people are conditioned to use it. Under compact fluorescent, they were chestnut brown. And under daylight, they were olive green. LEDs do not want to be completely sealed. Color shift and lumen maintenance fall off was profound and quick.

I'm talking measured in weeks. Somebody's trying to hit a number, not trying to build a space. Okay. Who has to lead it? The specifying community. I have printed t-shirts at home that say all of my homies hate CRI. Before we jump in, I want to thank five companies that show up for this community. Peerless, Kelvix, Ledflex, Diode LED, and Targeti USA.

Because this show exists thanks to their belief in designers and the way they work every single day. Speaking of designers, ask them what lighting really is and you'll hear it's the experience, the emotion it creates, what people remember when they leave the room. Peerless has believed that since 1892, and now it's re-energized with an in-house team that didn't start with technology. They started with designers. They sat in focus groups and asked what you're trying to solve, then prototyped, tested, and threw ideas away until what was left looked simple.

Aptitude is the proof they mean it. It's clean, distinctive linear system that moves through a space, across ceilings, into walls, and side by side. People at the launch event said the team thought of everything and more. A fresh version of Peerless has arrived. People, light, and what comes next, the possibilities. Visit peerlesslighting.com. What's the one thing that you can't put on a spec sheet and why? Or what's the one thing you refuse to put on a spec sheet and why?

So I will say the thing I think about most that people don't fully always understand is spectrum. So we might show a spectral curve or we might talk about an LED curve. But when you think about all the products, especially as you get into color mixing, it is so overwhelming that you really can't simply show a bunch of curves and say, hey, figure this out. So this concept of what is a spectrum, how does it affect a space, that's the one thing I really can't put on a spec sheet. But that I wish people would understand better than they do.

Why do you wish they'd understand better? So, you know, standard jokes, I like to refer back to the old days. Everyone remembers when they were a kid in a roller rink or a disco and you're like under certain kinds of lights and your clothes look different than they look normally. Or when I was a kid and we'd go to Sears and you'd buy something, go outside and it would look different. or even the same color red in a pair of pants and a shirt goes outside and they're now two different colors. That's metamerism. And really understanding on how to manage that, both in an architectural sense and in any application sense, really comes down to spectrum.

And you can use CRI or CCT or things like that as proxies for it, but that does not necessarily represent what's really going on with the lighting and how it interacts with the space. Yeah. Couldn't agree more. I do think that it is really relevant to understand that spectrum as a whole is what the light emits, but it doesn't take into account what the light is bouncing off of and how that plays within the space. And spectrum is a great measurement. It's a great metric to be able to put on a spec sheet. I will argue in favor of it for certain.

But all of that to say is, again, it's what the light emits. It's not how it makes the space feel. It doesn't tell you anything about how it interacts with the room that you're in. It doesn't tell you about what it's going to make this place feel like. And people will oftentimes misuse that metric because they think that, you know, oh, it's got a perfect spectrum. That must mean it makes these colors look perfect. And light just doesn't work like that. I mean, perfect's relative, right? Like the perfect spectrum is only perfect for the thing it's lighting, to your point, right?

When you think about your spec sheet... What's the one thing you want on there but doesn't end up there? Thermal expansion coefficients, and I did not expect to be able to bring that up here, but that's definitely one for me, especially doing lights on the exteriors, buildings and such. There is so much that happens to a luminaire or to a product on the exterior of a building that is the direct result of thermal expansion. Brick does not expand at the same rate as aluminum, which does not expand at the same rate as the polycarbonate or the PMMA lensing, which does not expand at the same rate as the copper that is the PC board substrate.

None of this stuff grows and shrinks at the same rate, and I wish that people could understand that. But there is no way that I'm going to be able to list that on a spec sheet without anybody else. Sure things move at different rates, right? They do. Can you give me like an analogy or something that helps me understand actually how often that becomes a problem? Every single day, temperature swings, right? We have a day and night cycle. It gets cold at night. It gets warm in the morning. And because of that, if I have a PC board made of copper that's on the inside of a silicone jacket,

that silicone jacket is pushing way bigger and expanding way further than the PC board on the inside of it. And so we have to take into consideration how these things are moving and how they're going to interact with one another. Let's say then I've got that silicone jacket inside of an aluminum channel. Now that aluminum channel is expanding at a different rate than the silicone jacket, and then they're both sat on a building that is also breathing and moving all day, every day, with the day and night cycles. I mean, this is literally every single day we put extra tension, extra stress, extra unnecessary forces on these products, and that is what leads to premature failure for some of these applications.

You know, the thing to think about is doors. Everyone's experienced a door. Like in your house in the winter, they tend to be sticky, right? And if you see doors, you'll see scrapes on the ground. But if the door's opening and swinging, fine. It's because of the change of the thermal expansion. And that's a seasonal thing, but everyone experiences that. No one's taking apart and inspecting a luminaire on the fly on the coldest day of the year and the hottest day of the year. So the issue exists, just people don't get to see it. And it ultimately manifests in, you know, potential connection going bad, a solder paste issue or something else where a part of it will fail.

And that's what ends up happening. Metrics are a big part of this. We look at CCT. We look at CRI. We look at IP ratings. We look at lumen maintenance. These are like four numbers that are table stakes. Maybe they're irrelevant because they're just assumed to be there. But there's a lot behind them, and I want to break all of them down. Which one should we start with? I pick. What do you pick? CRI. You good with that? 100%. Okay. I've got beef. You've got beef.

What is it? Why does it matter? Or why shouldn't it? So here's what I would say. Depending on where you are in the lighting experience thing, it can serve various purposes. So when my mom used to call me, say, five or ten years ago when LEDs were first coming out, and she's like, which LED should I buy? They had the lighting fax label on there that actually had the CRI and the CCT. And I could tell her, An 80 is better than a 70, right? And so part of it is understanding what that quality is.

It's just a single number. Like you said before, a lot of things are a single number that are supposed to represent a myriad of data. So just because you have a CRI of 80 doesn't mean it's the same as another product with a CRI of 80 in 90%. The example I was giving, a lot of that stuff was done with the first eight swatches of the original CRI. Vince is shaking his head. Yeah. So in that case, yeah, that was actually laid out, I think, in 1962. And the trick to it was they were trying to compare fluorescence because the world had all been incandescents. And after World War II, then we moved to fluorescence.

And the fluorescence, honestly, were very efficient. but not good at color rendering. Well, I got to stop you real quick because you said very efficient, but not, right? Efficient was measured in luminous efficacy in this case. Not light quality, just light output. No. Something that's really important to understand here. you're 100% spot on. And the trick to it is, as our country was exploding after the war, growth and manufacturing and distribution and homes and everything, the move was towards a more efficient because, frankly, just like today with data centers, our electric grid wasn't set up for that future demand.

And so moving to fluorescence gave us about a 10 times increase in efficacy, so lumens per watt. So it was great. The problem was it didn't do a very good job in color rendering. So industry, the IES and CIE and the major lamp manufacturers got together and they talked about how do we discern what's a good one or a bad one. And as I like to tell people, it's the pastel colors. So in the 60s, they thought, well, depending on how good you render these colors, we're going to give you a score from 1 to 100. And that today is still the core of a lot of people when they say, and this is the variance, people can say CRI.

They don't really always say which CRI they're doing. Is it the eight? Is it the next eight that came later? Or is it the full gamut that's available today? And by full gamut, we'll use relative terms. So it's a great way to compare a number. But even a metal halide can have a CRI of 70. And a LED can have a CRI of 70. And if you've ever seen those things side by side in an application, there is absolutely zero comparison. So for a number, they're the same. They are absolutely the same. But they don't represent the same performance.

So if they don't represent the same performance, what's going on? As we started off earlier, spectrum is the thing. It's not just that light in all of its wavelengths can be broken down into just one number. Sure, we can summarize and we can average these things based upon their strength at each wavelength. And we can do things like that to try to paint a picture. But the reality of it is visible wavelengths go from what, 390 to 630 or something like that. there's a few hundred different wavelengths of color and light that are absorbed in this spectral analysis.

And so, yeah, sure. We've put one number to represent hundreds of wavelengths. The composition of those wavelengths within that number can be vastly different from fixture to fixture. If they've, if this fixture has a higher balance in green, if this fixture has a higher balance in red, or if this one has a higher balance in blue, whatever have you, that spectrum can shift wildly, but that it can still arrive at that same overall average number of, oh, it's an 80. And so you can have completely different spectra, and as we talked about earlier, the light in the space bouncing off of other things is really what you see.

It's not the way that the source emits the light that you're looking at. You're never staring straight at a light going, oh, wow, that's 80 CRI. You're looking at what it does to the floor or to the walls or to the curtains. You're looking at those things and if there are different color mixes coming out of these lights, you're going to have a different impact on all of the environment around you. Even though they carry the same overall average number, the composition of that average leads to very different feels, same exact rating. And that's the reason why when LEDs first started coming out, they added the R9, which would be the next swatch after the 8.

And that's because LEDs generally did a poor job in red rendering, and the 9th swatch is saturated red. And so that became the LED – the leader in LEDs would refer to their R9 and talk about how good their R9 was. So they might say a CRI of – 80, but an R9 of 42, right? That was a way of saying, hey, listen, we've at least got a positive R9. And there are actually products that have negative numbers. Most people don't realize that, but you can actually get a negative number on any given swatch, not necessarily as a, so that's the trick is how do you, how do you take that one number and then carry it forward?

Okay. So what does this number mean right now in the current state of architectural lighting? So here's what I would say is, um, good for it's good. And I'll give you an example. If you take a standard or a fixed type of led. So I'm going to pick one, a standard blue pump with a YAG phosphor that creates the white light, right? Those are the most common. So like, what is that? Sorry. That's just a normal white LED. The one that we all think of when we think of white LED, the most common.

With the yellow phosphor on the top of it? Yep. That's that one. And so for that one, when you're comparing 70, 80, and 90... you can actually visibly see the difference. So, but once again, that's without changing the type of source. And really the spectrum, regardless of even color temperatures, are very similar, right? Now, if you go to a red, green, blue color mixing, That's a different thing. The CRI, it could be an 80, but it won't have the same visual experience as a CRI 80 with a standard blue pump and yellow phosphor, if that makes sense.

So once again, once you're in a space, and since the majority of the commercial and specification LEs still use today are that blue pump and the yellow phosphor, when you're comparing those, you get a good representation of what people experience in the field. It's going between the technologies that it really falls down. But if CCT was built around these fluorescent samples, that's not right. Thank you. If CRI was built around these samples that were catering towards the light source of fluorescent, what good does it do for LED?

It's a metric developed around a completely different light source. Yeah. I will say that the way that the test was developed, right, back in 1962, the CIA put together a test that said, hey, how accurately does this render this color in comparison to the sun? Because I think we can all relatively agree that the sun is what provides the light that we're all trying to match. And that's what the concept behind CRI is, is that, hey, how accurately does this light source represent this color in comparison to how the sun would represent that color?

And so, yes, it was developed for fluorescence, but the same test overarchingly is still going to get used. The big difference that they've made is how many additional colors now that we are attempting to represent accurately. As Jeff noted, the first test, CRI picked eight colors and they were all pastels. And as it turns out, there's not a lot of those in life that just naturally occur or that we deal with in an interior space. So they added then real colors like the ninth reference value, the R9 value. That one suddenly has red and it focuses on red.

And you know what else is red that people don't think about? Skin tones. And all of a sudden people look prettier because we focus harder on red. All of this to go back to the test itself was developed for us to use any light source with it because what we're comparing to is the sun. But I will argue that CIE republished the original CRI test and they added a whole new subset of colors to it. So now there's 15 colors to the CRI test. But then TM30 came along and TM30 said, why stop at 15?

but let's do 99. Heck, let's round it up. Let's make it 100, right? But they said, let's get a lot more colors because we need to understand the actual accuracy of this. And because of that, even just last year, the CIE, the group that put together the original CRI test, published a paper and said that TM30 is a more accurate version of this exact same test. We should stop using CRI. The CIE, the body that created the CRI test, published a thing that says we should get off of this because TM30 is more accurate. So what good is CRI doing for us right now?

So the industry, the entire industry is slow to move. It's just really that simple. So I always talk to people about bug ratings versus cutoff and non-cutoff. Everyone gets cutoff and non-cutoff. Only people who use bug ratings get bug ratings, right? So people still say, oh, it's full cutoff. And what they mean is light doesn't go up. That's what they mean. Or you zero. And the CRI will be the same way. So while I think it's great for communicating to my mom, and I don't have to give her a TM30 answer to the question. As you get to a, let's call it, climb the professional ladder, eventually it's a far better way of describing.

And what's hard about it, and this is a good and a bad. So the bad is it's not just one simple number. The good is it's not one simple number. So there's a fidelity, which is similar to what we do with the CRI. And then there's the gamut. So you can be highly saturated. And let's be honest, in the specification end, we want to make places pop. We want to make things look good. Sure. Controlling that gamut is a lever you can't differentiate in CRI, but you can differentiate through the TM30. So if the case of the simple argument is CRI is one number in terms of representation as a specification, but TM30 is two numbers, you're effectively doubling the question and answer session there, right?

Moreover, you're... multiplying the amount of data that is captured within those, because just like CRI's number is one number to average out of hundreds of wavelengths, we're doing the same thing with fidelity and with gamut. These two numbers, sure, you're doing good work to bring in additional considerations, but you're still using a single number to average, boil down hundreds of wavelengths and what they actually represent. But you have to be able to do this as a manufacturer, right? Like you can't expect people to know everything about everything and have the time to go down and sit down and research it.

Is it, is it the right thing to ask or is it too much to ask for people to think about two numbers versus one? So what I like to think about is self-selection, right? So I like it when people tell me I'm a more sophisticated person. I need to have a more sophisticated answer. So if someone calls us today, and you can do a polar plot with TM30 that does a great job describing the areas of saturation. If someone calls up, we'll prepare a TM30 report for them. Right. Because if you're really a professional, then you need to have that information in certain applications.

And when you do, we can provide that information. But just like the spectrum where we started, it's all about understanding the spectrum. We test the spectrum on every single product we make. But we just it's too much information. So we pretty much target what people need to know when they need to know it. So when do people need to know more than one number? You go first, I'll go second. When do people need to know more than one number? I'm going to actually go back to Jeff's climbing the ladder analogy. I really like that. The further on you get, the more that you understand about the space that you're building and the more that you understand about how you're going about designing, the more multiple numbers become significantly more relevant.

The less time that you are spending intimately loving a project or the less experience that you have within the industry, I think at that point it's a lot easier or if the budget's low, right? I think at that point it's a lot easier to want to rely upon a single number and single point of reference. But the more time that you need to spend intimately working with that space, the more time that you have spent understanding your role within the industry, I think the more relevant, more numbers become. I'll use, let's just say, a standard office building as an analogy. The stairwell. We provide stairwell lights. You don't need – a CRI-70 is absolutely fine for a stairwell.

You do not need to have a TM-30 report on that stairwell light. You just don't, right? Because what you need to have is visibility to get out of the building in a safe and an emergency. When you think about the other applications, like in an office, the CEO's office, yeah, you want to have high-quality wood, marble materials, nice carpet, and you want to be able to make those things look good. You want to understand that more complex TM30 to know that what you're putting in the office is going to look good, whether it's daylight coming in or electric lighting at night or in the afternoon.

So there's the two ends of the spectrum, and then you can blend in between. Hallways, yeah. Do you need to have a TM30 for the hallway? I don't know if that's required. If I was in a hospital, I would say you do because they transport patients who might be in emergency medical care. And we want to render them because medical practitioners do look at skin tone and colors and blood matters. And so having great visibility in a hospital hall makes sense. In an elementary school, maybe not so much. But when you're doing learning in the classroom, once again, I would lean in towards when it's the most important space, we want to put the right kind of lighting there so that people have the best possible experience.

Now to play devil's advocate for a second, do people need to specify two numbers if you know the products intended for that application and you've, quote, taken care of it already? That's a good one. I love how much responsibility comes back to you to just figure it out. I love this question because I think that this is one of the mechanisms that we as manufacturers actually get to. Right. Because a lot of times we're putting numbers on spec sheets for the audience. Right. We're doing it because a lighting designer needs it or because a specifier needs to have it written down somewhere because that's their control mechanism to make sure that all of their stuff is uniform.

But for us, we get this mechanism where we can craft a product and where we can put it and know exactly what its intended use case is. You know, a step light or stair light. We know exactly what it's doing. We know exactly what we want to look and feel like in that moment. And because of that, we have the capability to actually fine tune it to what we believe the best use case in that scenario is. And then some designer will inevitably come along and say, oh, can we improve this or can we improve that? But this is the first moment that we really get to say, okay, we know this space. We know what you want to do with it.

Let us run wild. I do think that there are application-specific products in which we actually do put ourselves into a position in which the metrics would be significantly less useful. Most people have, I'll just call it brand loyalty. I own the same brand car that I've owned since I got out of college. Right? You get comfortable with that. And I would say, as you get in the top half of the ladder, people become comfortable with a brand that they know. They become comfortable with the product's performance. And if it's a brand new product that they're uncertain about, they'll ask to see it.

And I've gone and shown people products and I've gone into the office and they look at how the lighting product interacts with the space they work in. If they need a visual check. As a rule, they understand the... sort of like performance levels that different products bring. So a stairwell light, they're not going to check because they know that it's not necessary. As you climb that ladder once again, then they're going to spend the time and they want to make sure that they're getting that right kind of product that's going to perform so that they're well represented with their customers, which is what it's really ultimately all about.

So where do we sit as an industry from a manufacturing perspective? On CRI. Is it, let me rephrase that question. From a manufacturing perspective in the commercial lighting industry, is CRI something that we still need to confirm and promote? Or does it need to shift? I think any sophisticated end user needs to understand or specifier needs to understand what their true performance is.

But once again, because so many people live on that bottom end of the ladder, once again, a wall pack on the back of the local grocery store. There's a lot of products that are transactional. You want to still be able to tell if it's decent or not. But then after that, you don't have to worry about it. So really, I think we're going to have CRI for a long time, not because it's a good metric that represents what we need, because it's the metric we've had for a long time and people are conditioned to use it. I would hope by the time I end my career, it will have sunsetted. Especially if the governing body who wrote it said don't use it.

you would think that would be a big push in the right direction. Is there, oh man, I hate to even ask this, but I'm totally going to. Is there like someone lobbying about this? Is there like a... Is there something in the DOE or, you know, is there something, is there a bigger force than the lighting industry controlling CRI that keeps it around? When they did it, ANSI was involved because they wanted it to be an ANSI standard. So I think there was a recognition that the CRI at the time did not do a good, just it's a fence that I've been talking about, which once again, and it's gotten better, but even despite that better, it's not good enough.

And they recognized that, I think at this point, 11, 12 years ago. And so there was a big, and I'll call it mostly industry-driven, but an effort to try to clean that up so that we got a better representation of what the product really does. And I'll jump in here and to Jeff's point earlier. I don't know that CRI will ever really die truly until we can convince people that RF is the actual functional equivalent of CRI. I'm not sure that it'll ever die because it's one number that's easy to use and that's simple to discuss. And going back to his analogy about when I want to tell my mom about what lights to use and what box she should pick off the shelf at Home Depot, yeah, we should use RF instead of CRI.

We absolutely should. But everybody's used to it and they functionally represent a very, very similar value. personal opinion, not what your company's going to do. Do you want CRI to stick around or do you want it gone? I have printed t-shirts at home that say all of my homies hate CRI and I gave them to all of my best friends. And I really hope that someday regardless that it's gone. TM30 is a significantly better metric. It gives us a lot more data, and I would love to see the world go that way.

But again, I do understand the value. I do understand its ease of communication. I see why CRI is probably not going anywhere, but the way that you phrased the question is beautiful. All my friends hate CRI. Do you want a T-shirt too? Yeah, it would be nice. And I 100% going back to that bug rating thing, right? We only publish bug rating. We don't say cut off, full cut off, right? We only publish bug ratings. That's the right thing. And that's where we'll end up. We'll get away from this. It just takes the industry moves at a very measured pace. I'm going to go there. Who has to lead it?

The specifying community, large manufacturers, you know, probably have to jump off the cliff. I don't think there's a, and by the way, I've been teaching about TM30 myself for about 10 years. I don't see that we've hit the critical mass of people in the marketplace understanding it well to put, to substitute one for the other at this stage. Yeah. I think it's a very fair point that you can't introduce something until there's a majority that's not only asking for it, but actually understands it. Just because 10,000 people took a TM30 course or lecture doesn't mean they understand it.

Yeah, exactly. Before we keep going, I want to spotlight a partner who shares the same obsession with design detail that this podcast is built on. And it's where Vince works. Kelvix doesn't just move fast, they move with purpose. Helping the design world turn ambitious ideas into seamless, buildable realities. The Kelvix team works at the pace of your project. Delivering tailored solutions backed by people who know how quality, timing, and precision elevate the final outcome. In every spec and every collaboration, Kelvix proves lighting is more than illumination.

Lighting protects design intent, sharpens the details that matter, and brings spaces to life with clarity and ease. See what's coming from breakthrough products to standout projects at kelvix.com or on their social channels. Every designer knows when the light is done right. You know? It disappears into the experience. And that's where LEDFLEX starts. At LEDFLEX, linear light is designed to do more than illuminate. It's engineered to shape how spaces are experienced.

Rooted in British manufacturing, Leadflex works alongside lighting designers, interior designers, and architects worldwide, supporting projects with detail, precision, and execution matter. They're not just a manufacturer, they're a technical partner, providing bespoke solutions, rapid prototyping, commissioning, and long-term support from early concept through final handover. If light is integral to your architecture, choose a partner who stays with the project. Learn more at ledflexgroup.com. And you know, I know, and you know, that every designer knows the success of a space depends on what actually shows up on site.

And that's where diode LED comes in. Lighting performance isn't an add-on. It's the foundation of every successful linear lighting project. Designers need solutions that carry ideas smoothly from specification through installation. And diode LED is built to support that reality. With industry-leading inventory... reliable delivery, and responsive support, DiodeLED keeps pace with real project timelines, not theoretical ones. Real solutions for real projects, no matter the scale. Learn more about what's happening in Reno, Nevada at DiodeLED.com.

Let's talk about something else people understand, which is color, color temperature. Sure. People understand this. I think like personally, I think one of the greatest things that's ever happened for our industry was the sale of terrible, cheap LED lighting in Home Depot and Lowe's and the basic consumer education of daylight and warm white. Like CCT wasn't there.

It wasn't there. But like in the world that we all live in now, people actually do somewhat say, oh, that's like warm or that's daylight. Right. But this is CCT. I bring you back to the top. What is it? Why do we use it? And does it matter? Yeah. So it is the best way to pinpoint a spot in color space where we can benchmark against. So once again, the incandescent, right, as it glows, you can see, and by incandescent, I mean any metal, as it glows, it moves up this curve.

And eventually you get to the point where they just extrapolate the curve out to 12,000, 14,000, 17,000 kelvin. But it was a great benchmark, and the incandescent being a key benchmark in our industry for, well, over 100 years. So the trick to it is it's a way of saying how close are you to what's considered full spectrum, which an incandescent largely is, especially down in the warmer color temperatures, and how close can you get to that? And that's really, at the end of the day, what it is. Now, the problem is in some levels it becomes a proxy.

without boring anyone about perpendicular lines and the black body locus, we'll skip all that. But just say, if I have a spot that's 3,500 Kelvin and I have two light sources that are 3,500 Kelvin, sometimes the inherent assumption is those two will look the same. And I'll take the really high road that most people understand. Go back to the blue pump with the yellow phosphor that creates the standard white. Another way to create white that we've all seen is a red-green-blue mix. If you pick out, let's say, near-perfect white, 4,000, 4,100 Kelvin, and you do an RGB and a blue pump yellow –

Those products do not look the same. If we lit ourselves up one half of our face with one half of the other, it would not look the same. They're the same CCT. And I'm talking about even if they're in the exact same position in color space. The other problem is there is some tolerance to it. So you can be above the black body and below the black body, be the same color temperature, but be so noticeably different that I always use my mom as the benchmark, that my mom would notice those two things are not the same and they should be. And if my mom can notice as an untrained professional, anyone can notice, right?

I mean, at the end of the day, that's why I think about it. So here we are talking about one number again, but it's just representative of something. And it can be the same but different. Same, but noticeably. Okay. And I think that's a really good note to make here that these things can be noticeably different, right? I don't want to dive deep into that black body curve, but like that, that's what makes this difference is whether you sit above it or whether you sit below it, because we graph colors into a space and then we draw this line in it, right?

And most of us have seen this line on this graph here. We draw this line in it. And if you're above it, your colors are more green, more yellow. If you're below it, your colors are more red, more orange. And even though the line in the middle is what we're correlating to, and it's this one finite point or infinitely small point that we're trying to correlate to, if I sit below it, well, that's my correlated point. If I sit above it, it's still the same correlated point, but the mix of the colors that lead into this are very different, noticeably different, even to the untrained eye.

Who's deciding where it is on this line? So I would say, um, The thoughtful luminaire design, of which there are lots of people that do a good job, the thoughtful luminaire designers try to bundle their products around whatever point they're picking in CRI space or in color space. So if you're going to be on the Blackbody Locust, you're going to be on the Blackbody Locust. And what you really want… is whether you're doing a panel, a troffer, a downlight, whatever.

Whatever that product is, you want them all to be with the same technology at the same spot. Because what you don't want to do is have a specifier order. And this is actually a challenge sometimes when you mix across lines. You don't want them to order a downlight that's washing the wall and then general ambient lighting for the rest of the room. And there's a color difference between the two. And it's just because one's above the black body and one's below the black body. Jeff, you work at Acuity Brands. There's 20 plus companies behind it. You guys don't get all your LEDs from the same place?

We spend an unbelievable amount of time that no one actually realizes. It's one of those things like no one knows what goes on, but we spend a lot of time doing what I just try to describe. We select just a very small subset of LED suppliers, and we put them through rigorous testing, not only initially, but even color temperature over time or DUV. and then also over the life of the LED. So we try to control those things, and there's ways you can get to a cheaper product by overdriving. There's ways to do that.

We avoid that because we want our products to stay not only consistent when we ship them, but pretty much over the life. They will eventually, depending on how long you use them, they'll usually be a little bit of color shift, but we're talking about something that should be on the decade or more. Everybody thinks it's as simple as what color temperature do I want my lights to be? And it's really not. There is a whole world to unpack about what's acceptable to purchase. Yet I don't think that's on the spec sheet. Like we spent money on the good $3,500 versus the cheap $3,500.

Can you take that and run with it? Yeah. So once again, I think that's where you go back to the brand stuff. Right. You know, everyone knows that when I was in high school, I had Nike sneakers and I wore Nike sneakers for years and years and years. They were great. They were comfortable. They were consistent. They always felt the same. I was I was a believer. Right. The same sort of thing can apply here. Once you get to a set of luminaire providers that you consistently see deliver, then you go with them. It's when you start to experiment away from that. And I'm not saying there's anything wrong with experimenting away. You just have to be able to be thoughtful about is that same level of care there as you've experienced with my Nike shoes.

If that makes sense. It completely makes sense. Yeah. So that's, I mean, I think to me, that's the key. And once again. But nothing's limiting manufacturer A or B or supplier A or B or shoe company A or B from putting a different version of, quote, the same thing in it. And there's no, so to speak, disclosure out there for someone to understand that. So... How many different manufacturer spec sheets that you say you do see with the asterisk and a footnote at the bottom that says specification subject subject to change at manufacturer discretion?

And why does that happen or have to happen? As we're on the topic, right? I mean, because sometimes there's a shortage in supply chain or sometimes there's a natural hurricane that happens and knocks out the only facility in the world that builds piezoelectric actuators. And you have to do other things and you have to find a different vendor. And you have to make changes to the way that you build your product or not necessarily to the way that you build it, but to the components that you use. And you have to maintain that same quality that people are expecting of you. There is that brand loyalty.

You need to be able to produce the exact same type of product every time. But there are lots of things that are totally out of our control where we have to find ways around it. And that's why we get those asterisks at the bottom of our sheets that say, hey – Sometimes we're going to need to make a change and you guys will need to trust that we are still going to deliver you the product that we promised we were delivering you, the promise that we've delivered for the last decade. We're going to deliver you that same product, but you have to trust us to make good decisions about what light engines, what sources, what components, materials, et cetera.

And I would add to that – Sometimes there's a positive upside that people don't always – like when we sell a product, 8,000 lumens. If I have another generational change in either the driver or the LEDs or whatever, and I could actually push it to 82, but then eventually if I ship that 82 as 8,000 and someone's got a room filled full of 8,000 and they want to replace one, they won't look exactly the same. So our strategy is you just do 8,000. And what you do is instead of being 30 watts, it's 29.4 watts.

And there, it doesn't match what the spec sheet said, but we've just given you a little less energy consumption. And we reserve the right to give you a better energy efficient product without necessarily having to rewrite the entire specification or break all the work that the entire chain from independent salespeople all the way down to the contractor have to change everything that's already established. Yeah. Because sometimes we expect jobs that go out years and years and years, and we're making continuous improvements. And if it's going to be relevant to the customer, we always expose that.

If it's going to change anything that's on the specification sheet in a negative way, we always expose that. Yeah. But you don't want to have to do that, obviously. Nobody wants unexpected bad news. That's correct. And we view it as a commitment to the customer about what we're going to provide. Sure. So we're going to stick by that commitment. So – Where are we at with this one, with CCT? Is it? It won't go away. It really won't go away. Now, I will say this.

As you get into certain applications, as you think about healthcare facilities, areas where they really think about circadian rhythms and that sort of work and matching. There's ways to really take it to its limits in order to do a better job of circadian matching, and there's a lot of benefits in that. That's a space that's going to need to be explored, I believe, over time as that technology gets better. But realistically, CCT is always going to be there because it's the most comfortable, and there really isn't another better proxy other than a full-spectrum analysis.

And then you need people who can understand that. I wince immediately as you say it because I'm going, oh, yeah, but nobody... Let's go into La La Land for a second because it's one of my favorite places. AI exists. Does that change maybe the ability? Could you just feed spectrum? AI could read it. Someone could ask questions and there's something that interprets it. I would love to jump in and answer this. And I'll go back to something that I said earlier too, that at the end of the day, what you're reading on the spec sheet is what the light source is emitting.

And what you are building and designing is a space for light to bounce around in. AI could read all the spectral data that it wants to, but what it cannot do is be physically present in that space and help you make a good decision about what it's going to feel like given the texture of your drapery. What if I give it all that information too? Exactly. The answer to that is, then yes. And I think it's going to be where AI could get. I used to have a pair of pants I used to wear when I trained people. And I loved the pair of pants for one particular reason.

Under compact fluorescent, they were chestnut brown. And under daylight, they were olive green. Just pause and think about that for a second. Those are two very distinct colors. Very different. And that's the point that I think is well made, is when you think about the space, you really need to understand what's going on in the space. Sadly, where lighting is on the total curve of the building, things like the carpet, like the material finishes on the furniture, all of that will matter, but they don't always know that at the design phase.

So that's probably the gap in the progress of how lighting plays out in an architectural development. It doesn't always have the answers that it needs to know to take the full benefit of what you asked and what we were talking about. I do also want to jump in with, I do think that AI has great uses and I don't want to be just the first guy to jump in and be like, no, AI is not going to work for this. Just because I have a pretty good rebuttal right off the rip doesn't mean that I don't see good uses for AI, for spectral analysis, for data analysis, for manufacturers largely.

I mean, honestly, for generating spaces and for beginning foundational design work, there are plenty of utilizations for AI within our industry. I just don't think that it will be able to replace a person in a space and the feelings. We're talking about design and creating spaces for people, right? CRI, CCT. Okay. I can be on board with that.

I want to take a moment to recognize a team that understands what every designer already knows. Light isn't a fixture, it's the soul of a space. For almost a century, Targetti has shaped how people experience architecture, using precision optics, performance, and that unmistakable sense of Italian design to elevate every moment a space offers. Because light isn't just seen, it's felt. It drives emotion, guides the eye, and transforms intention into atmosphere. For Targeti, light isn't simply the medium, it's their identity.

It's the craft, the legacy, and the commitment behind every solution that they create. Check them out and discover more lighting that inspires at targetiusa.com. Now I'm going to make you pick on two of the most boring things and how that relates back to people. Right. IP ratings and lumen maintenance. Wow. Like it's crazy to think about this is something that actually also still matters. Right. For very different reasons. I would argue it very much matters.

And I believe kind of like the journey we've gone on with color and light, I think if I pick IP, which IP is the one that kind of sits outside of those because the other one falls with the other ones. But for the ingress protection, I think the challenge is It's a great way of doing a number. It's done on a finite number of samples. It can't take into account a lot of variation. And there's been a lot of other attempts at different standards, NEMA 250, which gets you there, NEMA 4X. Or there's ISO ratings for things like clean rooms.

What's interesting is those all are other ways to approach the same problem. But at the end of the day, they're still not covering what a lot of specifiers want to know. And they just don't know how to articulate it. We might be able to answer it. But it's, how do I keep stuff out of my Luminaire? Right. The worst thing you can do in a health care space is have materials that are airborne in that space somehow get into a luminaire. Because when the luminaire has to be serviced, if it ever has to be serviced or has to be replaced, that is a huge burden on the health care facility because you don't know what contaminants could be up there.

So trying to make those things sealed really matters and doing it in a way that works well is really important. But there's not really a great metric in place today to do that well. So right now we're stuck with IP like we were stuck with CRI, not because it answers all the questions that people want to have the answer to, but because it's a standard we can all refer to and there's some consistency. But there's room to be better. What is IP? It stands for ingress protection. It is a two-digit number. The first digit is how protected against dust and other particulate matter it is.

The second digit is its protection against water. Oh, boy, is that exciting. As you get higher up in number, the more protected against either of those – types of, of ingress. There we go. Thank you. And you, and you say more, not completely. Correct. Because water is a nasty monster. It will get everywhere and you cannot stop it from even IP 69 K, which is like a ridiculous number.

Uh, most things in our, in our world will go from IP, you know, IP 20 to IP 68 and 68 is where we'll stop. Uh, because 68 is where you're submerging things more than a meter underwater and you're doing it for more than 30 minutes. At that point, you're probably waterproof, right? And so our industry kind of stops there. But 69K is for high-pressure jets at like 1,300 PSI with 150-degree water out of a nozzle that's like a millimeter and a half wide from no greater than three inches away from the product. We are talking water jet cutters are not this powerful, and your product has to be able to prevent water from ingressing

At that rate. And I think what makes them fallible is that it tells you, will water get inside the unit? Will water getting inside the unit damage the unit? And that's all it says. But steam and water are two very different things. And I made a joke earlier about, you know. Yeah, it's totally okay. We can put something that's IP65 in a shower or in a steam room because, you know, hey, it can stand up to high pressure jets. That's what the IP65 rating tells us. But steam is far more invasive than a high pressure jet.

And no, you should not want to default to something that's only IP65. in a shower scenario or in a steam room because they are going to get water ingressing inside of them. And even though these metrics exist, just like we've been talking about in the whole point of the episode, is that these metrics are flawed and fallible and that you have to be able to understand more about your space than just the number on the spec. And it's important to understand LEDs do not want to be completely sealed. So there is a air reaction in LEDs that has to take place.

One of our earliest learnings in LEDs is we worked with a partner and we built a perfectly sealed luminaire. We can put it under a meter of water. It would go on forever, but it didn't have enough interaction with air. There was very little air in the system because why would you put air in there? And what we discovered is the both color shift and lumen maintenance fall off was profound and quick. I'm talking measured in weeks. Whoa. Yeah. So most people, and that's the reason why hermetically, using a common term, or an IP68, you have to be thoughtful about how much air is in there.

Is the air recycled? So if you're working on pools or, what do they call them, fountains, You want to have some sort of interaction back out. And it can come through the conduit into the back. The conduit is not necessarily always sealed. There's ways to design around the problem, but you don't want to just simply seal it, which is a different problem once again. And we have one number that represents what's going on. We started off talking about variation with temperature and the ambient. All those things can have an effect.

And you need to layer on UL because UL then takes into account some of that. Oh, and UL doesn't use IP ratings. It's dry, damp, and wet, right? That's right. Now IPs are completely out the window, and the only nationally recognized testing laboratory that's got a list for this says dry, damp, or wet. And those are super specific. Yeah. Why should it be there? Because it's the best current proxy we have to compare products. It's not a perfect proxy. It's the best proxy. Yeah. That's why it's going to be there. And compared to what we've been talking about, it's farther down the cycle for being changed.

So, if that makes sense. And then you asked about lumen depreciation. I did. Let's just qualify that for a second though, right? We have light sources and historically they burned out. So when LED came along, some people stood up and said, well, it doesn't really burn out. So we got to reinvent the conversation of burning out. Like before we even talk about lumen maintenance, why do we care about when something burns out if it doesn't?

And I would say effectively, and I'll use two different terms, right? There's the will it burn out? Statistically, effectively, no, right? But what you really care about is are you getting still enough consistent light at the right color temperature in the long run? So as they degrade. There is a substantive DUV that usually occurs. And let's say this is dependent on a lot of variables, number one being the one we started out talking about, which is temperature. I actually did a calculation on a job we worked on in a walk-in freezer where they store meat in a facility.

We put a light in there. Someone asked the question, well, how long should the LEDs last? And I did the math. It's minus 60. And without going once again down a rabbit hole of technology, there's a simple model that says every 10C you move, you either double or half the life, depending on whether you're moving up or down. So if my fixture is rated for, say, 60C and I'm at, let's say, minus 40C, that's like order of magnitude longer life. And I actually calculated it out to almost a million hours.

The LEDs will be fine for a million hours. And frankly, the driver and all the electronics, once again, same sort of model, they'll last a long time. The only problem is power cycling. When you power cycle either the LEDs, which can affect thermal shock again, right back to where we started, on the boards and in the electronics, but short of that, they'll last a really long time. The problem is people will be like, okay, well, if that's the case, why don't we use a really push the LEDs and push the driver because we're going to have the benefit of this.

And it's that mentality of how do you get to cost optimization that then affects what that drop-off is. So all the time, I would tell people all the time, if you see a spec sheet and it goes from, let's just say, 7,000 to 10,000, the 7,000 will have more consistent performance over a longer period of time than the 10,000, assuming the driver and the LEDs are the same, if that makes sense. So when we think about that degradation, what people care about, and we're starting to see some of it, what people care about is how long is my light going to look the way that my light's going to look.

And that's where that change will come. And I would tell you, based on history, it'll probably occur in 11 to 13 years. So if you think about LED technology becoming commercially environmentally relevant, let's just say a little over 10 years, the conversation around lumen maintenance and meant more back then versus now, yes or no? It was a deal then. It's less a deal now, but it is still a deal. Yeah. Why was it a bigger deal over a decade ago versus now?

The LEDs themselves were just fundamentally less efficient. Right? We'll take the efficacy, right? Because the LED itself produces only two things. light and heat. And basically, as we've gone up that from, say, some of the early LEDs I worked on that were literally 60 lumens per watt at the LED level to something closer to like 200 plus, right? And it's a, once again, the functional relationship between temperature and life, it is a much, much less of a deal now because we've taken so much of the heat out. When I first designed for LEDs, we had to look at the electronics temperature and the LED temperatures.

I would tell you now we don't spend as much time on the LED temperatures as we used to. And you can see that in heat sinks. You can see that in the way people design products because the LEDs themselves have gotten so efficacious. I'd say from our standpoint too, you know, lumen maintenance is one of the things that we use when we're weighing our warranty periods and things. And how long do we want to stand and claim that this product is going to operate exactly as it did the first day we shipped it? The problem that I have with it is much like with the rest of the numbers that we're discussing over the course of this episode is that the tests in and of itself are just extrapolations, right?

Like it's – what does it mean for something to have a 70,000-hour lumen maintenance period? I mean running 10 hours a day, heck, I've got kids that aren't old enough to have seen these lumens depreciate. It's a – It's a heck of a math game that we play to bring some people, some specifiers, some comfort. And to the point that we were making earlier about, you know, this used to be more important. When we didn't have a good understanding of the lifetime of an LED, it was more important for us to try to extrapolate and for us to try to guess.

But now that they've been out for a little while and we've actually watched them degrade and we've actually watched these things change their color temperatures and their outputs to a level that is notably different from when they first shipped. Now that we have seen that, we've done enough engineering work to be able to mitigate those things. And so it doesn't mean quite as much as it used to when this number first came out. It still does mean something because, hey, this is the proxy number that we claim represents roughly the lifetime period of this product.

But just like all the rest of the numbers that we're talking about here, it's just a proxy. And heck, realistically, most of these LED strip companies haven't had product on the shelf long enough to be able to actually see the end of their lumen maintenance period. And so largely, it's a number that we're taking a guess at for some younger companies. When you look at all four of these, you have to report them. Is that a fair word? You have to confirm them. You have to state them. We calculate them and we provide them to customers because they're common asks.

It behooves us to state them. Okay. So you state these. How much does this impact coming up with the products, designing them and bringing them to market? I would, it's a meaningful impact. Each one of those tests take time and designing them to be the right way takes time. You know, I don't want to, I mentioned the LEDs have gotten far more efficacious. The drivers have gotten far more efficient, but there's still consideration about the temperature of the drivers. Some of the fundamental components within a driver are more thermally sensitive than many of the other components in a luminaire.

And so when we think about it, yeah. They've got capacitors, man. Capacitors hold chemicals. Yeah. And so realistically, understanding that, and that really affects more probably life in some cases than really what we're talking about. I worry a little bit. I would say my priority would be some of the electronic components and then probably color shift and then probably lumen depreciation, probably in that order. And just people need to understand that. And by the way, that's not something that's changed because electronic fluorescent drivers or ballast that we sold in 1988 had the exact same issue. Right. I mean, that was the fundamental limitation.

Yeah. Lots of opportunity in the industry. So like you said, it behooves you to provide that information to your customers, right? They have an expectation of what they want. Is that characterized by what's been provided or their own self-evaluation? That's a really good question. What drives that expectation? I think largely, and the way that you called out the question is beautiful because it really is their own expectations. This is why we pay these people lots of money for them to have good design opinions, right?

They come to this with an expectation. But as we've noted throughout this, all these spec points that we have mentioned are just if you're staring directly at the light source. It's most important to see how they actually fit within the space and what they do to the room that you're in. And so there is this, yes, it's part the designer. Yes, it's part the space. Yes, it is part the spec sheet. But the spec sheet is the best tool that we have to communicate these things. And so we use these proxy numbers. I do think that all of these things are relevant and we'll need to continue to work towards them.

They'll need to be foundational design tests for us because these metrics are the language that we use to communicate with consumers and customers. Yeah, but the problem is a contractor can do design without having any design mind, and they just look at those four numbers. They sure can. So then what you're publishing, I feel like, carries a lot more weight. So we talked about the ladder before. I think towards the bottom of the ladder, these things matter a lot because they're trying to make sure that their stuff looks fundamentally consistent, and 5,000 is not 3,000 Kelvin, period.

So they have the ability to make an intelligent buying decision that gets them generally very correct. Right. As you get farther up that ladder and you get to people who actually care about rendering the spaces, how things look, true performance, differentiation, that's where asking the question, what about the TM30? What about these other things? And we do feel tons and tons of questions from people. And if we get enough questions on a product… We'll put it on the spec sheet. So we learn, we learn. And that's how spec sheets grow to be those 12 page monsters is because over time we absolutely just get tired of answering this same question.

So this is a surprise question that's come to me through this conversation, but here it comes. Does another metric need to actually be developed to serve the bottom of the ladder that doesn't exist? So I would say the metrics we have serve the bottom of the ladder well. Yeah. I think the things we've talked about, the TM30, changing the IP metric, I think some of those improvements, providing real spectral data, that's for that top half of the ladder. That's for the people that really have the sophistication to know how to apply that information in an intelligent way for a lighting design.

And we can provide all that data. I mean, we test and collect all that data. It hasn't hit a critical mass that you say we should just put it on the spec sheet yet. Like is it going there or is it just – is the top of the ladder too lightweight to ever get there? No, because we do answer these questions for lots of people on the top half of the ladder. I mean we have tons of sophisticated customers that ask very detailed questions that go into all of these topics we've been discussing today. And we provide a lot of extra technical information that would just overwhelm the 30-page spec sheet.

That once again, if you don't recognize that's an important consideration for you, then we're not going to overwhelm you any more than we may already today by providing that information. But if you're a discerning customer, then we want to provide that information that helps you to make the right decision. We've talked about four numbers, replacements, alternatives to them. What's a number that you get asked to make better that doesn't actually matter? I started with this one earlier. 99 CRI. It's so, at a certain point, there is no ability for humans to tell the accuracy, the difference in color accuracy between 96 and 99.

I mean, at a certain point, you just can't even see it. The only way that this even becomes possible to recognize is with spectral measuring tools and other sophisticated equipment to be able to actually see the difference between these light sources. Anything, I would argue, 95 plus, anything above that, guys, we're just asking for silly diminishing returns here. We're not actually designing products. Somebody's trying to hit a number, not trying to build a space. Because to go from 95 to 99, you can comply, you can achieve that.

But upstream of that, what has to happen for you to be able to put that in your product and what does it cost? That's really like more – not even just the cost but the efficacy. We've spent so much time on this. The higher your color quality, the lower your lumens per watt. And at a certain point, you're jamming so many different phosphors into this mix that you wind up with a really inefficient thing. Sure, I can make the perfect color as it correlates to the sun. But again, that's perfect color correlation in terms of the sun.

What if I want it to feel warm? Just because color is accurate doesn't mean it feels right. I think there's still a huge opportunity around circadian rhythms, health, that whole segment that isn't easily articulated in a spec sheet. But I think as we look over time, I believe there'll be an increasing move towards two things, full spectrum. So in other words, you can make an LED, which is less efficacious, but that does a better job doing full rendering across the entire spectrum. And there are applications where that has value.

And I think there's times when you should use that. And then this sense of dynamic lighting over time. You can do it well. You can do it poorly. But the opportunity to do it combined with what's really going on in the natural world, I think, is an opportunity. I think we've got the technology here today. We don't yet have the pull in the marketplace for doing that level of better lighting. So I think that, to me, is the one thing that's not on there that I look forward to hopefully seeing in the future. I have a question. How would you represent that with a simplified number on a spec sheet?

Is it a matter of... you know, CRI at temperature A and CRI at temperature B? Or is it that we, you know, that we have to now list a graph where we show CRI through the color temperature curves? Like, how would you go about listing that on the sheet? Or if you think about the natural cycle of spectrum or color temperature to use a proxy is over the day, how close do you match that over the day? They're just boiling it down to one number. Statistically, how far are you off of the ideal circadian rhythm for your place? Which, once again, can be geographically specific.

I'll tell you right now, the circadian experience in Ireland is not like the circadian experience in Arizona. Those are two different things. And then the question is, which one should we really match and why would we match it? Should we match the locals? Should we match just some generic Dubuque, Iowa circadian experience? And those things are the things that we have to figure out before we can get to... And I don't want to say just a number, but we'll say, by proxy, a number that represents doing a good job of that. And I think there's a lot of research that's going on there. I think there's a lot of opportunity to provide.

I'll give you my favorite thing I like to tell people. Incandescents were profoundly more efficient and changed the entire world. Since the day of the incandescent, every technology we did in lighting, so I'm going to march through them, incandescent, fluorescent, really hard to believe, but compact fluorescent, metal halide, high-pressure sodium, and low-pressure sodium, constantly got better and better and better and better at efficacy. But I would argue, and I think almost anyone would agree with me, the thing they trade for efficacy was quality.

The thing LED gave us back is it gave us the efficacy, and gave us back the quality of light. And so how can we take that quality of light to the next functional level? That's where I think the opportunity is. Across not just what we've talked about, but everything in the space of metrics, is there a number we can get rid of that we don't need? Sitting with the engineering group all day, I would argue absolutely not. That there is no such thing as a useless number. That's why they exist. And that's why spec sheets consistently grow and grow and grow.

It's because over time we realize that there is more and more useful data out there and that I'd be hard pressed to find a number that I didn't love. Right. One over 157 is the best of them. Is it useful or is it just like we can create it? I think answering that question is unimportant, right? Like CRI, is it useful? It depends on context. Is it useful is always such a contextually loaded question. And so to that end, somebody will find a context in which that number is useful.

And I would argue that we just put it on there. There might be someone who hunts me down when I say this. Coefficients of utilization based on room cavity ratios on a chart on a spectrum would be – and I'll say a lot of them have gone away, but they're not all gone. The lumen method we can do away with? We could probably get beyond the lumen method. I'm pretty sure we could do that. But that would be the one thing that I've seen that still exists in some places that probably can go at this stage. So I would love to meet the contractor who uses the lumen method. Who cares about that one?

I mean – Yeah, to poke fun at it. I sit corrected, by the way. Yeah. To poke fun at it, there probably is one contractor left who still actually understands what that number means and uses it. And effectively, they're doing some form of design by leveraging that data. That's right. But you don't want to overwhelm. Tyranny of choice, tyranny of data. Too much data can interfere with the ability to make an intelligent decision. So we have to be thoughtful about how much information we provide and the method in which we provide it.

It's my final two cents. That was good. I just had a teary of choice lines coming.

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Is a Label Real? 2 Lighting Leaders on Compliance, What It $$$, What They'll Never Tell a specifier

    Nov 17, 202659 minAudio

    Anyone can put a compliance icon on a website. Signing your name to it is when it gets real. Host Sam Koerbel sits down with Donna Sumner (Sr. Director, Strategic Operations, Acuity) and Tom Howe (VP Sales, Kelvix) for...

    Credit the people on this episode

  2. The Group Writing the Rules for Lighting + Keeping Them Alive | CEO + Associate Executive Director

    Nov 10, 20261 hr 17 minAudio

    For six straight years, the Illuminating Engineering Society couldn't finish a year in the black. Last year, it finally did. This is what it cost. Colleen Harper (CEO, IES) and Brienne Willcock (Associate Executive...

    Credit the people on this episode

  3. Beauty as Medicine? A Hospital Designer Talks Neuroaesthetics, Design & Healing | Brooke Horan, HDR

    Oct 27, 202630 minAudio

    What happens when a hospital designer reveals why beauty isn’t a luxury - it’s medicine - and why neuroaesthetics proves art, light, and design are critical to healing? In this episode of LytePOD, host Sam Koerbel sits...

    Credit the people on this episode

  4. Why Some Rooms Just Feel Good — A Top Interior Designer on Lighting’s Secret Power | Sarah Kuchar

    Oct 13, 202638 minAudio

    What happens when a top interior designer who's spent a decade crafting unforgettable spaces reveals why lighting isn't just another layer in the design - it's the secret weapon that makes or breaks whether a room feels...

    Credit the people on this episode

  5. Why Billionaires Hire a Lighting Designer as Insurance | Pete Romaniello, IALD [4K]

    Sep 29, 202658 minAudio

    What happens when a lighting designer who's lit more than 2,000 homes explains why billionaires hire him as insurance - and why the most powerful design tool isn't complexity or technology, but simplicity, trust, and...

    Credit the people on this episode