Pressurization is a common strategy for protecting spaces against the infiltration of smoke. However, the solution has a kind-of bad press as "not-working" or "incapable to meet its design goals". We know, that the systems are as good as their design, and in this episode with my guest, Grzegorz Sypek, we try to bust some myths around PDS systems. We touch on the important design points and the properties of modern solutions available in the market. We also discuss the standardization of PDS systems in Europe, giving a glimpse into incoming EN 12101-6 and EN12101-13. If you seek help with the design of pressurization systems for your buildings, feel free to contact Grzegorz @ gsypek@gmail.com LinkedIn: https://www.linkedin.com/in/teknolink-gsypek/ ---- The Fire Science Show is produced by the Fire Science Media in collaboration with OFR Consultants. Thank you to the podcast sponsor for their continuous support towards our mission.
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Transcript
From the show. Tap a time to play from there.
SPEAKER_01Hello and welcome to the Fire Science Show session forty-seven. Today the podcast is taking a little twist into world of engineering, more than science, but actually it's uh science-based and uh factual-based engineering, so it's very welcome in uh the podcast lineup. Uh we're gonna talk about pressurization systems or pressure difference systems, PDS as they're going to be referred in the episode a lot. And these types of solutions are used in the different types of buildings, especially on evacuation routes, on stairwells, lobbies, sometimes corridors, in order to create a pressure difference that prevents smoke from entering the space that's protected.
SPEAKER_01A very simple idea, very efficient potentially, and also an idea that is known to be quite difficult in employing in a real building. Many places of the world people just do not believe these types of systems can work, or there's a history of these systems not giving the performance they were expected of. And for that reason, there's a lot of happening in Europe. There's new standards that will be published very soon. EN 1211 Part Six and 13.
SPEAKER_01So this this will be an important step forward in creating a new future for pressurization systems. But it's not just standardization. We want to talk today more about the fundamentals of these systems and in a way a Polish twist in their design, which led to creation of very successful applications which have been used in practice in dozens, if not hundreds, of buildings, also very tall buildings, with great success. And uh yeah, that's the story we want to share with you today.
SPEAKER_01My guest for this topic is uh Grzego Slipek. He was an engineer at company SME who developed uh one of the first adaptive uh pressurization systems in Poland. And now he's an independent consultant who also works with PDS systems. He has worldwide experience uh from Middle East through Europe, and also he has been an active member of CEN committees that wrote the standards I've just mentioned. So he's definitely a good person to talk about uh systems being used in Poland, how they differ from the solutions around the world, and how can we actually provide safety through pressurization in very tall buildings.
SPEAKER_01So I hope this is an exciting topic. It's it is for me for sure. So I hope you'll enjoy it. And yeah, let's not prolong this, let's uh spin the intro and jump into the episode. Welcome to the Fire Science Show. My name is Vojcevinski, and I will be your host.
SPEAKER_01I'm here today with a good friend, Gzagosh Supek. Hello, Gzagosh, great to have you in the podcast. Hi, Vojtek, good to hear you. I'm glad to be here. Thanks. Uh I'm glad to have you in the show. Today we're gonna talk about the important thing that is pressurizations of various compartments in fire as a means to protect spaces. But before uh we start, I would like to say a few words. I would like to dedicate this episode and recording to our mutual friend Michał Kozak, who unfortunately went missing a year ago on Madeira.
SPEAKER_01Uh Michau was very active in the pressurization community in Poland and in Europe, a member of the CN committee working on the pressurization standards, member of SFP and a good colleague. So uh Michal, wherever you are, we're thinking about you and uh missing you, man. This is for you. Yep, exactly. This is for him. This is for you. Okay, Gzegosz. So there is this funny thing, pressurization systems, and in Poland, we routinely go into 200 meter tall skyscrapers, install our PDS systems in there, commission them, and they just work.
SPEAKER_01And whenever you step outside of Poland and tell that to someone, they go like, it's impossible, they don't work like that, it's not going to work. And yet here standing with I think 15 years of experience in applying these types of solutions, we seem to have built a national confidence in this field of protection. So I'm really wondering what is the difference between the Polish way of pressurizing buildings and some things you observe outside of Poland.
SPEAKER_01That's the same pressure. I just feel we're in like completely two parallel universes, one of which technical solutions are really advanced and amazing, and that is Poland. And in uh in the world when where people just don't believe in this type of systems.
SPEAKER_00Well, yeah, that's a very good question, and it's good to start from this particular question. You know, from my point of view, actually PDS, we can discuss a lot whether PDS works or not. That depends on the project, that depends on the quality of different works, and that depends on the variety of different factors. However, from my point of view, we don't have alternatives for the time being. So we use such systems regardless whether we like it or not. The only issue is that we can do it in the in the right way or we can do it in a little bit European way, sorry.
SPEAKER_00Well, in a global way, which is a little bit old school way from today's perspective. You know, the world is changing continuously. So the same thing uh happens when when we talk about the PDS. So if we discuss systems, multiple injection systems, multiple earths, multiple point air supply, systems, constant capacity fan, and a mechanical pressure relief tamper at the top of the stairwell, it may be not sufficient for advanced buildings. You know, look at the modern buildings. Say they are getting taller, they are getting more advanced.
SPEAKER_00If we collect a variety of different data out of those buildings, it is packed with electronical devices. So I don't see any particular reason that we shouldn't follow the same manner. I mean, that go the same way when it comes to fire safety systems, especially since this is not something which is only fancy, you know. Sometimes it is highly required to design fully functional PDS for given buildings.
SPEAKER_01Okay, I'll I'll give some background to our um our friends outside of Poland on what happens in here. So, as Gregos mentioned, constant uh capacity inlet fan and a pressure relief damper would be a common way to pressurize different compartments in many buildings. However, in Poland we have more active systems. I mean, it's it's funny when you think about it now. Everyone is talking about Internet of Things and uh advanced smart buildings and everything.
SPEAKER_01And in Poland, in terms of pressurization systems, wow, that that's exactly what we have. It's just we didn't call it like that 10 or 15 years ago when uh these things were burned. And now uh you say that they're not only fancy, but they truly have better capabilities than solutions that were used for decades over the world. Maybe you I I know you were there when these systems were invented, uh, developed, uh, designed, engineered. Uh maybe you can tell us the story how you went from uh or maybe how you didn't even go to the root of pressure relief Amber.
SPEAKER_01What was the thing that pushed you into these smart systems and and how this revolutionized uh the Polish market in the early 2010s? You were there, you've seen it.
SPEAKER_00Yeah, yeah. I I I've been there, you know. I I I I still remember it well. So it's you know, the basic idea was to really solve the problem, not to hide the problem. Because, you know, what we do globally in terms of pressurization or PDS, let's call it PDS, it is more comprehensive because this is not only pressurization. We wanted to solve the problem, and the problem was that in very tall buildings, especially in cold climate or very warm climatic zones, there were significant problems with stack effect, variety of different factors, I mean, very variety of different phenomena which are not discussed at all, actually, at the moment for the time being.
SPEAKER_00For instance, air flow resistance of the stairwell, we supply quite huge amounts of air to the stairwell, and we've got one opening at the top of the stairwell, so the air has to flow through the stairwell, and we've got some specific airflow resistance of the stairwell. And our objective, let's start with the objectives. Our objective is to have specific air uh pressure difference across the door or the fire compartment at the fire floor. So we want to have positive pressure in the in the protected space and some reference pressure, not necessarily negative pressure in the fire compartment or the fire floor.
SPEAKER_01Sorry, we with pressure in the protected space being higher than on the other side. Exactly.
SPEAKER_00Exactly. To keep vertical or not necessarily vertical, but but escape routes free of smoke to prevent infiltration of smoke and to have directed airflow from the protected space to somewhere else, outside the protected space, again to prevent smoke from coming in into protected space. And uh let's say standard PDS operates in two modes. One mode is pressure mode. Where when we have all doors closed, I mean the protected space is more or less airtight, and the other one is airflow mode when we open the door, and it strongly corresponds to the fire scenario or an evacuation scenario from the building.
SPEAKER_00So there is a huge discussion on how many doors shall be open simultaneously at the same time, and it depends. It is not like we each and every time we can open three doors, for instance, into the stairwell, it depends. And so we have started, let's say we have started from the scratch, we we made sure that PDS avoidable at that time are not sufficiently advanced to be applied or to be installed in very tall buildings, and that was the starting point for the entire discussion. Then we have decided to do some uh real-scale tests, and we have carried out such tests in Kraków in 90-meter tall tower.
SPEAKER_00It was actually a part of the high-rise building, which was like 30 years old at that time, but it was very useful because we were able to do that to do the tests for over two years in the real scale, which is quite unique in the global scale, because each and every time when I look at the PDS, I either see CFD or some analytical calculations, you know.
SPEAKER_01There are very few or small or small scale experiments. Exactly.
SPEAKER_00Exactly. And and we went for the huge project, which was it was very useful to develop and to design the final version or final shape of the PDS. So we wanted to solve a few important problems. We wanted to solve the stack effect issue problem, and we wanted to solve wind influence problem because both are very important and both are different, because you know, stack effect is rather static. I mean, it results from temperature differences inside and outside the building.
SPEAKER_00So, you know, the temperatures don't change that much. Whereas when we talk about wind, it is very dynamic. So we wanted to have a solution for both. So we went through the internet, we went through you know different design concepts or different PDS concepts available at that time, and we didn't find anything which was you know sufficient from our point of view to be installed in the building. So we developed a system, let's say active control system, which which is modular, that it's very important. Very often it happens that you know PDS are being designed for specific projects.
SPEAKER_00So we do we we take different components and integrate them on-site, which is not a very reasonable approach because it is very important, the interactions between components are very important. So we wanted to have the well-defined modular solution which would be suitable for different buildings, and the architecture of the PDS would vary depending on the height of the building, and the same system can be used to protect or to pressurize vertical escape routes, uh, lift shafts, and firefighting lobbies.
SPEAKER_00Because when we talk about PDS, it is very important to point it out that we are talking about a huge part of the building. We are not talking about the stairwell only. Because when I when I've been living in Dubai for two years, you know, and each and every time when I discussed PDS there, it was the stairwell. Stair pressurization system. That that that was how they called it. So it's way more than that. So, yeah, the system was developed basing on real-scale experiments, you know, supported by CFD analysis, and then laboratory testing of the components of the kids.
SPEAKER_00We'll talk it over a little bit later.
SPEAKER_01Yeah, okay, let's go back to fundamentals. You've mentioned it was designed to battle stack effect, and we know that many design guidelines recommendations would say that you're ought to subdivide your vertical route into smaller sections, say sections, yeah, 30 meters or something uh to prevent the stack effect. I think the underlying physics is that over 30 meters the stack effect will not develop into very huge pressure because in in a very tall building you can have easily 100, 200 Pascal from the stack effect only.
SPEAKER_01So if you sub the the idea was to cut it into subsections, but we also know that this is wishful thinking. If you have a stairwell and people are evacuating in it, and someone opens doors to both of them, which are interconnected with some compartment, the stack effect will not uh wait patiently until the path is sealed, but it it will just form. And I think this is a major problem in the systems that often wishful thinking is part of the design. You would omit some of the physics, omit some of the consequences, because otherwise it's it's very difficult to prove the system will be working.
SPEAKER_01And now you're telling me you're designed a system for 90 meters there well. I should be surprised, but I'm not because uh as a consultant on the Polish market, I I've seen buildings twice that high which had modern PDS systems in them. Uh, more than that, I've been doing CFD and commissioning of these systems, and they just worked. So uh if possible, maybe you can share the magic how stack was handled.
SPEAKER_00Yeah, there is very actually there is very little magic in the overall concept for the for the PDS because it is strongly based on science and technology. And I hope you still remember that we had a chance to meet in Dubai in 2016 at the SFPE conference, and for one of the projects over there, and actually in Dubai, for a 220 meters toll tower, we did a design concept and carried out some CFD simulations to prove that you know, for this very, let's say for this extremely warm part of the world, the system will work as well.
SPEAKER_00Because in in Europe, in the US, we mostly have problems uh during the winter time where it's colder outside than inside. So when the stairwell or the vertical escape routes operate more or less as chimneys in in buildings, so the move there moves from the bottom to the top of the building, but in the warm climate, we've got a reverse stack effect. And if you go to the hotel in Dubai and you take a look at the stairwell, you will see that there are swinging doors at the bottom of the stairwells, you know, and they are not closed all the time because they are partially open due to the stack effect.
SPEAKER_00So, you know, the system the problem is clearly visible in the buildings. The issue is that there is very little real-scale tests and good commissioning of the of the systems across the entire world, more or less, because the knowledge about PDS is relatively low. But that that's a different story. You know, coming back to your to your question, the magic, the magic, there is no magic, as I said. The overall idea is to deliver to supply air to the negative pressure zone and to exhaust it from the positive pressures.
SPEAKER_00Because in each every building, we will have both zones where there is a difference uh of air temperature outside and inside the building. So we supply air at the bottom in the winter time and exhaust it uh at the top, and we do opposite uh during the summertime when the temperature differences are opposite. So we wanted to create airflow, directed airflow resistance throughout the stairwell to produce specific pressure drop or airflow resistance throughout the stairwell, you know, to compensate the stack effect. The structure and the architecture of the system is relatively simple because you've got air supply, you've got reversible fans at the bottom and at the top of the stairwell, and you've got pressure differential sensors and you know some control panels to control the airflow inside the stairwell, to produce specific pressure difference over pressure in the protected space, and to create specific airflow resistance in the stairwell.
SPEAKER_00Where uh during the times where we've got pressure temperature differences outside and inside for you know isothermal conditions where there is no temperature difference, you just pressurize the stairwell in the in the common way. But you have to keep in mind, you have to remember that the system, the architecture, capacity of the system strongly depends on air leakage rate of the protected space, it strongly depends on airtightness of the building facade, and it strongly depends on air release provided, because you know, air release it is critical in in most of the cases, and sometimes it is highly underestimated, because in Poland we mostly use mechanical air release for PDS, right?
SPEAKER_00It results from our national regulations, whereas in different countries it is being done and carried out in different in different manner. For instance, in Switzerland or in Germany, they mostly use net natural air release. So, you know, it it is that therefore I'm talking about PDS, not only about pressurization, because from my point of view, pressurization is just air supply side.
SPEAKER_01Yeah, I'll I'll I'll take you there just in a second. Uh any sufficiently advanced technology is indistinguishable from magic, and I'm sure what you just described uh as something you commonly use will be considered magic for many. And the realization that to create the necessary overpressure, you sometimes have to remove air. That's a kind of a brilliant thought and not uh one that you immediately get, but it it really works to remove the air from the positive pressure zone in the part of the building where it is created.
SPEAKER_01Basically, you with this simple move, you reset the stack effect in the building, bringing it under control and have being able to provide uh the pressurization, the designed pressure over the the whole height of the building. That that's brilliant. And now you you've brought me into a very important subject what do we do with the air that we supply? And uh this is extremely interesting because as you mentioned, uh some people would consider it stairwell protection system or stairwell pressurization systems.
SPEAKER_01And for me, I always thought that the stairwell is in a way the most important thing we protect, and in the same time the most difficult thing to protect, because during the evacuation and rescue operation processes, you cannot you just cannot be sure that it's going to be sealed in a way you expect it to be, or the standards would expect it to be. And but this is not the end of the protection. In Poland a common thing would be a lobby or vestibule, however you call it, a small compartment next to your next to your opening to the stairwell, to the um elevator shafts where you would have additional point of protection, being a secondary PDS system or a secondary inlet designed in a in a very special way to always make sure this lobby is positive pressure against the corridors.
SPEAKER_01You so you s you gain like an airlock uh part of your system, like in spaceships in movies, it's just you don't have to wear a spacesuit to enter that airlock. And and uh now you open the doors to your uh fire room, and we know fires make a lot of products, a lot of hot air. If there's water, it is gonna evaporate. So these whole things are adding to pressure being in a way produced, goddamn it.
SPEAKER_01I'm a scientist, I shouldn't say like that, but for the podcast, yeah. The pressure is being produced in there. So it's necessary to make sure that the route the air flows is from the staircase from the lobby through the floor and somewhere. Now you've said a popular thing in Poland would be to provide mechanical outlets at the space that the fire is. So you basically suck the air from there in a mount that lows this flow path of air always form.
SPEAKER_01In other solutions, you can open the windows, uh, but what's the issue with that? Does the wind uh trouble you or why are you worried with the systems based on natural exhaust?
SPEAKER_00As you as you already said, we are each and every time in in very tall buildings and even in relatively low buildings where we use the PDS, we are dealing with phenomena that influence our PDS dynamically, I mean, in an active way. So it's hard to imagine that we can you know fight those those phenomena and those those interferences in a passive manner. You know, we have to react to what's Happening in the building. So if anything is passive by default, it is very hard to imagine that it can counteract something which is highly dynamic.
SPEAKER_00You know, when we talk about the air release, it has to be provided to have the airflow from the specific airflow because each and every time we will have some airflow from the positive pressure zone into the fire or five floor. But it has to be, you know, specific value of this airflow because it's also defined by the standard. Actually, we are talking about airflow velocities from 1.0 meters per sec up to minimum, up to 2.0 meters per sec, depending on the fire scenario. I mean evacuation scenario and you know intended use of the PDS.
SPEAKER_00Because we are talking about evacuation or we are talking about evacuation and firefighting on site. So this is the phase of the of the fire, depending on the phase of the fire. In the initial phase, we assume that it's 1.0 meters per second is sufficient, whereas when the fire is fully developed, we need at least 2.0 meters per second from the pressurized and protected space into the fire floor to prevent smoke from coming in into the protected space. What troubles me is that every solution has some bright sides and dark sides, and it when we use mechanical air release, it's more comfortable from the design point of view because when we suck air from the from the fire floor, from the fire compartment, from the air release path, it will flow from the positive pressure side to the air release, mechanically supported.
SPEAKER_00But when we talk about natural air release, we have to keep in mind that the shafts would be significantly bigger. There is no fan at the top of the of the shaft to you know to suck smoke and suck air and smoke from the from the fire floor. And it is even worse when we are opening the windows because PDS tend to work properly where the building facade is airtight. Because if it's very tight, as for most of the modern buildings, because we are talking about different things that influence the airtightness of the facade.
SPEAKER_00And airtight facades are highly required at the moment because of energy use and things like that. But when we open the window with the given floor, we will equalize the pressures inside the building and outside the building, but only at this floor. So it is additional interference for our PDS. Because when the building is airtight, I mean the entire facade is closed and tight, then we will have stack effect because it is very important to understand that that stack effect happens and occurs not only in the vertical escape routes, it occurs in the entire building, in I mean, inside the building.
SPEAKER_00So when we are opening the facade to the ambient, we've got additional uh uncontrolled interference. So, from my point of view, mechanical air release is is is a very good option, robust and very reliable.
SPEAKER_01I'm also in favor of controlling, however, it it sometimes is I will admit uh with Xagosh here, we only touch the pinnacle of the engineering that goes into PDS systems. And even though we we seem to make it quite easy that we have grid solutions, we have great systems in Poland, we can manage that. It's not that you go into PDS shop, uh pick a box from the shelf, drop it on your building, and it works. There's a whole hell of design that goes along with that. And I mean here it's not that uh we uh magically possess the knowledge uh to do that.
SPEAKER_01It's as Grzagosh mentioned, they have spent years in a real building playing out, trying out solutions, testing what works, what does not work, and and finding the correct combination of systems to finally create the first kit that went onto the market. Now, a decade later, we have multiple uh multiple companies that specialize in in delivering these types of systems. There's um uh a lot of engineers who specialize in designing them in Poland. So by saying it's easy, I I think in in a way it's like uh in mathematics, you know, if there's a if the problem exists and it was solved, it's easy.
SPEAKER_01If it was not solved, it's hard. Same here. You solved it so it's easy, but in for to engineer it, it's a whole lot of work. Now I wanted to switch a bit to the much more fun aspect of designing new technology, new system, and that is standardization. I know you've been involved in in uh writing the EN 1211 part six and part thirteen standards for like uh probably one-third of your not very long life.
SPEAKER_01No, the standards are a compliment, yeah.
SPEAKER_00Thank you, thank you.
SPEAKER_01You're welcome. But but that's true, that the standards have been written for more than the last decade, and uh you've been there for for a long time. So so and now today, many friends from UK, many friends from other European countries are reaching out. They hear that we have experience with the 1211, the uh part six and part thirteen already. Because we have, in fact, for the last decade, thanks to espionage of you and your colleagues been working with the principles in of these standards, and we we've put them into buildings already.
SPEAKER_01So people are reaching because the standards are about to be published, people are reaching to us to to know our experience. So maybe you can tell us a few words about the standardization process of this standards, uh what's changing, what what what's the the key differences, and do you think if this standard can uh truly open a new era for pressurization systems in Europe? And before you start, I will just think about your clever answer, and I I'm just gonna briefly give introduction to why Alt 12101 Part 6 was horrible and created nothing but issues.
SPEAKER_01So there was a standard, I think it was 2005 or 6 published. Uh certif harmonized. It was a standard that allowed to give CE marking to kids. The only issue is it did not give an answer how to do it. And that created a hell of a problem. It was more like a design standard on how to design a pressurization system to your building. By design I mean calculate leakages and choose whatever performance criteria you want to achieve, not really how to design it. And that was a source of very, very big problems because suddenly you have a harmonized standard in EU that means you can see mark with that, but you really could not.
SPEAKER_01And yeah, we we had to find a way out. We found a way out through the projects of the new standards, through national uh assessments, and building our own uh laboratory following the new procedures that were being born at the time. And uh Josh, tell us how how were they born and what's changing? What was the big fuss about?
SPEAKER_00Yeah, actually, you've already touched the point. We used to have already with Tronly and 1211 Part 6 from 2005, based on BS, former BS standard, and it was a it was a funny thing because it was a product harmonized European product standard, which mostly dealt with uh design of this PDS.
SPEAKER_01Fantastic. So thank you so much.
SPEAKER_00It should have never been published actually. So that was a decision, and it is very common. It was very common in Europe, it is still very common in Europe that we talk a lot about different things and we would do it very slowly. So now we've got a new European EN revised EN 1201 Part 6, which will be a pure product standard, which probably it's it depends, but I'm not sure if it's gonna be harmonized European standard or not. But this is a different story.
SPEAKER_00We need reliable and decent products to be installed in buildings when we are talking about fire safety, so it is clear for me. And we've got this set of European EN101 standards. We built our PDS and not only PDS, different fire ventilation systems out of those components. So there is a huge discussion whether we can use this product or not, and we need harmonized European standards for different products. And the idea of EN101 is very good, so it gives us clear recommendations and requirements for products installed in buildings.
SPEAKER_00Uh when we talk about design, it is a new European standard EN12101 Part 13, which will cover design, acceptance testing, commissioning, different things for the PDS in buildings. But um there are some significant changes. The idea was it should be simpler, I mean, easier to apply, easier to use for designers, because we had we used to have different classes. I mean, six classes of PDS in the previous EN 2011 part six. Uh now there are only two classes A and B, and there are some changes. I'm not sure if it's revolution, but it's definitely easier to be used and to be understood from designer's point of view, and it is actually the most important thing for this standard to be successful on the on the market.
SPEAKER_00I have, for years I've I've heard that you don't have to use this standard because it is not obligatory to use this standard because it is not possible to harmonize or or to standardize the design process. However, when I looked you know across the world, I mean in different countries where I had the chance to work, I see that designers strongly prefer to use some standard, some design standard, because it's easier for them, it is safer for them, it is simply better. So I think this is very important that we have the standard in Europe which is way more detailed than, for example, N FPA standard, which deals with PDS or whatever in America, in the US.
SPEAKER_00So I think this is the step ahead. It is not perfect, it is to be developed for over a decade, as you as you already mentioned. So it I think in many cases, I mean in many ways, it's already outdated. So I'm I'm expecting that you know the revision of the standard will start soon. So this is the problem of Europe, you know, it is quite passive, and we need a lot of time to introduce important changes and updates. But but nevertheless, I think it is a step ahead, and I think it's gonna be useful because there are some problems mentioned and listed, and there are some solutions for those problems as well.
SPEAKER_00So I think it is it's it's gonna be it's gonna be a step ahead once published, and it's gonna happen soon.
SPEAKER_01That's great. I I certainly appreciate the changes to 12.1 Wild Part 6 where it gives uh testing methodology. Uh, as I've mentioned before, in the time where there was no good regulation, meaning that the existing standard was useless and we had to pursue the national assessment pathways to put these fire safety solutions on the market safely, we were heavily inspired by the work ongoing in in your committees. And in in fact, we back then we've already implemented all the electromagnetic, all the environmental compatibility tests for the parts of the kit to make sure from this perspective they are safe.
SPEAKER_01And we have built a hydraulic laboratory to test the the hydraulics aspects of this of these devices where we test its reliability and uh the capabilities of the system to achieve their performance points in terms of pressure or flow within a certain uh time from opening and closing the doors between the protected and and the fire compartments. So there there is quite advanced laboratory base already existing very second oldest in the world, actually.
SPEAKER_00So congrats on that. You know, it's it's a huge achievement. Thank you.
SPEAKER_01Thank you very much. And and hit it has been extensively used already. I think we've went through at least 10 manufacturers of PDS systems in Poland and in Europe, in fact. And this also gives us a good basis uh of experience on how to uh how to deal with this uh with these systems. And uh, if any of you listeners are interested in testing your PDS, uh you're very welcome to send me an email and we are very ready for you uh to test this for the new standard, not yet accredited because the standard does not exist, but I can promise you that day one, when it's possible, we're gonna opt in for accreditation for that test trick.
SPEAKER_01Uh so a little a little insert of my marketing in in the podcast episode. But I think it's important that there is a basis of knowledge that that exists based on experience.
SPEAKER_00Actually, there is it is again very important to mention that we've got components, we've got kits, and we've got systems. Um we very rarely test real-scale PDS in the lab, but we have to clarify what is the intended use and what is the intention of the lab tests. It is to assess and validate whether a specific combination of predefined components is capable to meet some design objectives. If it's not capable to do that in the lab, in the smaller scale, we can really doubt that you know it's gonna work out in the in the real building.
SPEAKER_00So this is this is this is this is that was one of the most complex and long-lasting discussions in the in the comedy because people tend to not understand what's the difference between kit component and system. Once it is tested in the lab and it passes the tests, it can be installed in the building, more or less, you know, right? And then if once it's installed in the building, it's it has to be tested again. This is not instead, this is additional tests to provide and to guarantee.
SPEAKER_01I will tell you something funny that will not surprise you at all because you were involved in that. But we already have been testing kits that were designed for particular buildings undergoing refurbishment. When you have a new building, it's very, let's say, easy to engineer the system based on the existing market solutions for it. But when you have a 50-year-old skyscraper or 30-year-old skyscraper, you work with what's available in the building. It's uh you cannot go to the owner and tell them, okay, I need five new shafts in the core of the building.
SPEAKER_00Or I need to uh or I need to, you know, test it for two weeks or or a month in your building, you know.
SPEAKER_01Or I need to close the building and test it for two weeks. Yeah, exactly. So we've done that. We have been modifying the testing uh station to as closely as possible mock up the existing building and test the capabilities of the system as close to what's gonna be in the real building in terms of leakages and stuff like that. The only thing that is very hard is the stack effect, obviously. But but still, outside of Stack Effect, everything can be pretty much uh modeled on the rig. So it's it's funny, we we don't even have a standard published, and we've already gone into performance-based engineering pathways with that.
SPEAKER_01And I think this segues me to one of the questions I really wanted to ask you. From the in the beginning of the talk, you said that uh it's a kit, it it contains pieces that you can use at buildings as necessary. I wonder how did you how do you determine what's gonna be needed on the building? What type of engineering analysis that you pursue to design a system for a building, or you just go to a catalogue and uh pick a system for 170-meter uh tall building. That that would be cool, actually.
SPEAKER_00No, yeah, it's it's not that easy, but pretty much it works pretty much like this. We each and every time you have to start with design objectives, right? Architecture of the building, I mean the tall height of the building and and and building parameters are just one group of input parameters for the for designing the PDS. We start with the design objectives, and we also define design pressure differences, desired airflows, and you know, all the parameters which actually describe the PDS.
SPEAKER_00So, and basing on this database, we designed PDS, but what I wanted to say is that we don't experiment with combinations of different components from one project to another. So today I'm working as an independent consultant for over two years. So, you know, I'm mostly based mostly on my experience because we we had a chance to work on some tallest buildings in Poland, and also I had a chance to work on some projects in the in the Middle East. But so I work using my experience, uh practical experience, but it has to be calculated by the design stage.
SPEAKER_00You have to prove, and this is also one of the requirements of the new EN 1211 Part 13, that for buildings taller than 60 meters, you have to prove at the design or at the design concept stage, you have to prove that the system is capable, your PDS is capable to meet some specific design parameters. So there is a door open for CFD analysis, which are still not very common when we talk about PDS, because we model fire, we we model spread of smoke, temperature differences, but we don't most in most of the cases we don't do CAFD for PDS.
SPEAKER_00And I think this is a very good tool to prove at the design stage that the system works properly, because the parameters of assessment of the PDS are very clearly defined. There is a pressure, specific pressure difference, there is specific airflow, and that's more or less it. Uh and this pressure difference corresponds to the opening force, which is which is actually critical in most of the cases when we talk about PDS, because we don't we we are not allowed actually to exceed 100 newtons in in Europe and 133 newtons in the US.
SPEAKER_00Maybe US guys are stronger than Europeans, or I don't know what's the reason for the difference, but we don't want to have pressure differences that result in exceeding 100 newtons of door opening force. And this is really the most important parameter. So just to put it all together, we want to have some specific pressure difference across the door at the fire floor. We want to have direct airflow from the protected space into the fire compartment to prevent smoke from coming in to the protected space, and we want to have the possibility to evacuate from the building, so we don't want to have any doors closed due to the exceeded door opening force.
SPEAKER_01And with the CFD, I assume that you don't model just the compartment where the fire is taking place or the floor. It's more like a simulation of the whole building to model the stack effects and other effects um involved.
SPEAKER_00Um, exactly, exactly, exactly. The best option would be to model the entire building. This is not always possible because the models are getting bigger and bigger and it's very time consuming. So it depends how much potential and how much time you can spend. But um, at least we need to model vertical escape route, which is protected, and representative floors in the building. And this is when we talk about the building, this is more or less it.
SPEAKER_01And what about shafts? Like what about like elevator shafts? Sure, definitely.
SPEAKER_00You know, we we we need to model all parts of the building which strongly influence the pressure distribution across the building.
SPEAKER_01So, like all the possible paths of the city.
SPEAKER_00Exactly, exactly, exactly. You know, when we talk about outside of the building, it is even more complex because we are dealing with dynamic changes of wind speed, and also the location of the building is important if it's located in downtown. We've got a variety of different tall buildings around the building, you know, it also influences the pressure distribution on building facade. But what is, from my point of view, what would be the most important thing, I'm not talking about the wind tunnel testing of the some specific part of the city, rather talking about pressure distribution on the building facade.
SPEAKER_00Because what is important for me, for me, from my point of view, is the pressure difference between protected space and some reference space in the building, and to the outside where there is an air release, for instance, at the building facade. Because when the facade is airtight and I don't open it for the means of PDS, so there is no particular need to model the outside of the building. So I can only limit the model to the building inside.
SPEAKER_01Yeah, here is an another point why mechanical exhaust would be maybe uh better than actual openings on the facade, because you would have the outlets at the roof level usually, or at the technical floor, which hopefully would be the same floor when you have inlets, just maybe opposite side of the building. But this simplifies both wind and both stack effect because these effects will uh often even cancel out or or have that that yeah that they can be compensated. So so a good point.
SPEAKER_01And have you considered I I know uh for American audience, they are pretty much going like what the hell? These guys are doing CFD for precious. We have content for that. And have you considered like a simplified models to model that?
SPEAKER_00They well actually they do more or less the same in Switzerland. It's even more common in Switzerland because especially around Zurich, there is a canton Zurich, they require the they've got some local regulation. Uh these are not even national regulations, these are just canton regulations for some part of Switzerland where they require to do CFD to do numerical analysis, not necessarily CFD for the PDS, uh, for buildings taller than 60 meters, and they are quite quite advanced. Uh and they mostly use quantum for that.
SPEAKER_00But this is not that the this is not that this is definitely not the equivalent for the full-scale, I mean fully advanced CFD, because this is like a part a kind of simplification of the of the nature of the real world. So I think it is somewhere in between. We do analytical calculations, hand calculations for the for the PDS all over the world. And most of the cases, unfortunately, though those uh hand calculations are limited to the capacity of the fan only and to you know sizing the mechanical pressure relief temperature top of the building, and that's it, which is way too less.
SPEAKER_00I mean, which is way too little to assess the PDS in the real building. So we do it commonly like this. On the other hand, we've got CFD advanced. CFD simulations, which is the perfect way to once it is carried out properly, this is another issue, but let's not go into too many details on that. The CFD is very good to uh analyze the processes when it comes to PDS in various buildings. Somewhere in between, we've got this contam zone note models, right?
SPEAKER_00So it is way better than hand calculations, but it is definitely not the CFD.
SPEAKER_01I think I have to ask some expert on contam for the podcast. I have a few people in mind, maybe. Look forward to towards the east. There will be an episode one day coming.
SPEAKER_00What would be uh Vojtek, what would be the difference? What's the advantage? Is that even if you don't have very powerful computers like you do, you've got a huge number of licenses, you've got big computers and stuff like that. So you've got all the required infrastructure to carry out advanced, big-scale, large-scale uh CFD simulations. In most of the cases, we have to limit the size of the model because we are not able to do the to perform the the fully advanced CFT simulations. So ChromTom gives you the advantage that you can model entire building.
SPEAKER_00Even outside the building, you can do some some you know calculations. So you don't need to have you know that much advanced computers for that.
SPEAKER_01So you can always outsource it to us, we'll handle it. We're cheap.
SPEAKER_00Actually, I don't use CromTam actually. We're not cheap. So you know, I do have I do hand calculations. I do hand calculations, so no worries. I will not outsource it.
SPEAKER_01The thing to take out of this episode if you need help and engineering a system called Jagosh and And I will go vote to do CFD for that. And we'll we'll do CFD for you. So you have a full you have a full package there. One last thing I wanted to ask you because uh we we've touched a little when talking about laboratory. So you've said that laboratory tests are like prerequisite for uh that the system will work on a building. We know that uh if it well, the fact that it works in lab does not mean it works in a building, but there's a good chance it will.
SPEAKER_01If it doesn't work in the lab, then I'm sorry it's not gonna work anywhere. But when you go into a building, you've designed all this system, how do you prove it works?
SPEAKER_00Yeah, actually there is a um let's say testing procedure, real scale testing procedure, commissioning of the PDS procedure described in EN 1211 Part 13, which gives you clear requirements on how to test it, you know, and what has to be measured and what is the required accuracy of the measuring equipment. So it's relatively well described and it is quite easy to be carried out in the building. The only thing it may be time consuming.
SPEAKER_00Therefore, I'm 100% for active controlled systems, active control PDS, because I've got a chance, even if it's installed in the building, I've got a chance to recalibrate it, to reset it, to introduce different settings for different components. When we talk about mechanical solutions, which are you know pre-defined and pre-configured, for instance, on the production side, there is very little chance to change and to adjust anything in a building. And additionally, you touched on a point that I want to mention again that in the lab we do tests in a relatively small scale.
SPEAKER_00But what is the major problem in most of the cases when we talk about PDS? This is not necessarily the stairwell because the pressure distribution inside the building strongly depends on the uh on the temperature differences outside and inside. But the most important part of the, I mean the most critical part of the PDS turns out to be the firefighting lobby because we've got relatively small, uh small room, I mean small space, right, where we supply quite a huge amount of air, right? And we open and close the door, and that this is our interface between the air release path and the protected space, as you said at the beginning.
SPEAKER_00The airlock, yes. The airlock. So it is it is that the smaller the spaces and the more airtight the spaces, and the more air we supply into this specific space, the harder to control pressure differences in this in this specific space, because we've got huge pressure jumps when we close the door, and we then we we open the door and we have to increase capacity of the fan very fast. So it has to be very well controlled and very stable, on the other hand.
SPEAKER_01Yeah, you you you you you can literally have uh hydraulic hits in the system, like the waves of pressure formed by by closing the the system. And we we've seen that in lab that we we we've seen in lab kits that were jumping from this actually, like literally jumping into air because of the of the force that was in there. And that was not due to some miscalculations or wrong design. It was just because you're trying to put a lot of air into very small space, which is very airtight. And this is critical. This is critical.
SPEAKER_01I agree. This is a challenge. This is a challenge.
SPEAKER_00Therefore, you know, the the the the let's say standard PID controllers are perfect. Uh, when we talk about maybe perfect, when we talk about the stairwells, and when we talk about firefighting lists, which are relatively big and the airtightness of those spaces is relatively low. But when we talk about uh the lobbies, which are small, normally small, uh I would even say tiny, so we need to have something more advanced when we talk about controls. The PAD controller has this characteristic that the faster it operates, the less stable it becomes and opposite, right?
SPEAKER_00So it's it is not possible to configure it properly. So for firefighting lobbies, we've got the option to use at more advanced control systems and actuators for the system, I mean the control devices, or to go for, let's say, more or less constant capacity PDS, regardless of the position of the evacuation door, whether it's open or closed. So I'd like to say that uh from my point of view, basing on my experience, if when something is advanced, it doesn't necessarily have to be very complex.
SPEAKER_00It also can be relatively simple. The architecture of the system can but can be relatively simple and understood from my point of view. But for instance, when we use electronically controlled components, it is a matter of reliability of the system, right? So in the systems I recommend and design, all electronic components are continuously monitored. We cannot be sure that the system will work properly or not unless we don't monitor the entire system continuously. This is not like we will start the system once per year during the periodic testing of the of the PDS.
SPEAKER_00We need to be sure that it will operate uh more or less throughout the not more or less throughout the entire year. So in the systems we developed, for instance, it it normally goes through routine testing. It is a self-testing system. So for instance, air supply fan is being started once per day with a very little, very low capacity, not to interfere with the use of the building, and we also open and close mechanical shuttle dampers.
SPEAKER_01What I mean is that during the tests we sometimes change the leakages a little bit, not a whole lot, but a little bit, because in the in the building it's enough that someone puts a carpet in uh in a corridor to change the leakages. And so we don't want to have a system that works only fine-tuned to particular leakage, and when the leakages change a little bit, it goes into oscillations or something. So usually clients have to develop some sort of systems that every now and then test the leakages and adjust the parameters of the PID controllers to match the thing they they see in the building.
SPEAKER_01And Ghagosh, well, time fly is great when you're having fun. You said it's it's a boring topic and we're gonna wrap it in 30 minutes, and uh an hour has passed and we could talk for another one. But uh I will stop you there. But uh I will give you a chance for like a final statement. If you have a message to our friends outside of the Poland who want to design safe uh PDS systems, outside of calling uh you and me, what should they do?
SPEAKER_00I do, you know. Please do not believe that PDS in general don't work. Because they are PDS. Uh they don't work because this is our fault when they don't work, actually, you know, because this is in most of the cases, this is a result of bad design or bad quality of components. So the the overall idea is good from my point of view, and if it's properly designed, it it has a chance to be very useful in terms of saving people's lives and in supporting firefighters on site.
SPEAKER_00So, besides, I don't see any alternative for the time being to replace PDS with anything else. We've got two ways to design good PDS or to design bad PDS. So I'm definitely for uh designing good ones. And I think it doesn't have to be very, very complex and very hard tasks to do. And we have to keep in mind that we've got different buildings, and each and every time PDS has to be tailor-made to the building. So when we talk about simple projects, let's not go into CFD analysis, let's not go into some advanced, some complex systems, let's use what we normally use.
SPEAKER_00But when we talk about buildings taller than let's say 100 meters in harsh climate, I mean climatic zones, in in parts of the world when it's cold outside and when it can be very warm outside, let's don't underestimate problems with PDS and let's not copy. We if we have a building which is 30 meters tall, let's say, let's not multiply PDS into 150 meters by simply copy-paste, because it will not work. So each and every time we have to think reasonably and we have to behave in a in the in the let's say smart way to pre to use and to to to design and to use the smart PDS.
SPEAKER_00And the PDS will never be smarter than us, so it is our responsibility.
SPEAKER_01A PDS cannot compensate for the stupidity of its creators. Exactly. That's a brutal final remark. But yeah, we we are engineers, let's engineer. Um, thank you, Gzegos, for this talk. And let's stay in touch. And I I hope to work with you on many, many PDS projects around the world. Uh thank you very much.
SPEAKER_00Thank you very much, Voittek, and uh for invitation for your time. And I hope it's gonna be useful for you guys. And in case you have any questions on the PDS related issues, do not hesitate to contact me. I'll I'll I'm for you.
SPEAKER_01All the contact details in the show notes. Thank you guys. See you around. Thanks, Josh. Great.
SPEAKER_00Yeah, bye-bye, take care.
SPEAKER_01And that you believe a little more in that they can work actually and provide safety in uh the applications that are used for. If uh you have any questions related to the systems, the implementations, or just the standards, you are very free to email Gzegosheloadmi to give his contact details. So they're all in the episode show notes. And if you wonder about how to test your own system, how to make sure that the system you design uh will work in the application you need, or maybe you need help in modeling that, we're very happy to help you at the ATB so you can also contact me.
SPEAKER_01I hope this episode was uh useful to you, and well, more useful stuff coming your way next Wednesday. So I hope to see you there. Cheers, bye. This was the Fire Science Show. Thank you for listening and see you soon.
Glass towers, deep basements, five-star hotels, airports, and mixed-use megaprojects are rising across the Balkans, and the fire risk is no different there than in London or New York. The difference is the system around...
When your smoke control CFD run fails by one meter of visibility and the knee-jerk reaction is predictable: add capacity, add fans, add cost. Here I would propose to stop for a minute and take a bit different path - to...
Fire safety engineering based on our codes and legislations often stops at life safety and code compliance. However, in the world of insurers, there is much more beyond that - a critical question is “what happens to the...
Modeling the consequences of a fire is what most of us do day to day. Modeling how a fire actually grows across real materials, under changing heat flux and ventilation, is the part we tend to avoid, hiding behind a...
ASET/RSET is the fire safety engineering idea that sounds almost too clean to argue with: the building must give you more time to escape than you need to get out. But once you try to prove it in a real project, the...