Skip to content
PodSubs
ShowsPeopleGuestsJobsNewsEvents
More
BlogPodCred
Menu
ShowsPeopleGuestsJobsNewsEventsBlogPodCredNetworksSign in
Join nowSign in
  • Shows
  • People
  • Jobs
  • News
  • More
    • Guests
    • Events
    • Blog
    • PodCred
    • Networks
    Join nowSign in

Fire Apparatus & Emergency Equipment

Fire Apparatus & Emergency Equipment artwork

Debunking Relay Pumping Myths

Sep 11, 202641 minAudio
ShareXLinkedInFacebookWhatsAppEmail

The latest episode of the Moving Water podcast tackles persistent misconceptions surrounding relay pumping. Hosts Chris McLoone, Andy Soccodato, and Bill Adkins challenge the common myth that relay operations are strictly meant for rural departments or extreme long-distance lays. Instead, they reframe relay pumping as an adaptable solution for overcoming friction loss and elevation changes, even during short-distance lays or urban booster-backup operations. The hosts analyze common operational challenges, such as communication gaps, over-pressurizing attack engines, and using relay valves versus direct engine hookups. They also address how water supply officers streamline command and optimize fire flows. Packed with practical field insights and real-world anecdotes, this discussion offers actionable advice for pump operators working in any fire service environment.

Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.

Transcript

From the show.

Nat Kapustin: Hi, Chris McLuhan here with fire apparatus and emergency equipment. Welcome to this episode of our Moving Water Podcast. As always, Andy Sakadado is here with me, as well as Bill Adkins. And today we're going to talk about relay pumping myths. ⁓ you know, we've we've we've touched on this a few times during this. We're gonna give a quick, just a quick review of what we're talking about when we talk about relay pumping, and then we're gonna get into some of those myths. There are gonna be some myths. For there are going to be some myths against. ⁓ and then we're gonna talk a little bit about ⁓ you know, like what's wrong, what you know, what's wrong and and why. you know, ⁓ you know, and then there's also ⁓ there is also sometimes, not all the time, but sometimes ⁓ a feeling that maybe this is just a rural thing. Now I can say it's not because I've been part of drills and part of ⁓ large diameter hose relays, but you know, we wanna we wanna touch on that too. So Bill, I'm gonna start with you. And then Andy, you can you can add add on to this. ⁓ but before we get before we jump into it, you know, just go through relay pumping for me real quick. When we're talking about relay pumping, what are we talking about? Yeah, mostly ⁓ when the first apparatus ⁓ arrives, ⁓ they may not hit the may not be able to hit the water supply right away. in the royal setting, we may be a lone driveway. So they we don't want tankers to back up driveways. So we will drop a tail at the end of the driveway and allow the next due apparatus to relay pump to us so that we could set the tanker operation. But in the urban setting, it could be a long driveway itself, or maybe they can't find the hydrant right away. So they they position where they would normally position the crew gets out and starts doing their work, and the next apparatus will bring in the water. And what that apparatus will do is hook up to either a hydrant or be ready for the the water shuttle ⁓ operation. And they will push their water. They start we usually will start with our tank water if we can and then ⁓ establish the water supply and then push it forward to the first due apparatus. I think, you know, what what I see is ⁓ in my experience, a lot of people think that ⁓ you know, when we talk about relay pumping. They get in their head that relay pumping is only a tactic when we have to go a long distance. So we need to have, you know, three, four, five, six pumpers in a line to overcome a distance problem. And and while that is a way that ⁓ we can employ a relay pumping operation, ⁓ the way I like to think about it is a relay is really anytime one rig is pumping to another rig. That that's a relay. It could be a thousand foot, it could be a hundred foot, right? If we have a pump that's pumping to another rig, that's a relay. ⁓ now the complexity of the relay is going to depend on a lot of other variables, and I'm sure we're going to talk about them here, but ⁓ you know, things as simple as a lot of us in in the fire service today are using the tactic known as the booster backup, right? Where the the first engine doesn't lay in, the second engine comes and lays that supply line and then pumps their tank water directly to that first engine. That's technically a relay. It's a very short relay. We're just giving our tank water to the next rig. So ⁓ you know, while most of us have a very specific ⁓ operation in our mind when that term relay pumping comes into into ⁓ the the forefront, right, it's important to understand that it really is a broad topic. Anytime a rig is pumping to another rig, that's relay. So when we when we talk about myths ⁓ regarding relay pumping, it can go either way. There could be misinformation about why not to do it, and there could be misinformation about why it is something that we should do. Andy, what are some of the myths, ⁓ if any, that that you have heard against relay pumping? Like you're getting into an argument with somebody and I mean you just kind of me mentioned one of them that a relay the the only time you use it is for you know to to ⁓ compensate for long distances. Are there other ones that that you have heard of arguing against a ⁓ relay ⁓ a relay operation? So so one of the major disadvantages of any relay operation ⁓ is the more rigs we get in into the operation, the more complex the operation becomes. And therefore we all have to, you know, make sure that we're on the same sheet of music. So ⁓ it can become complex with more and more rigs, but ⁓ depending on the scenario, right? You may need that. The way I like to think of it is, you know, the relay pumping is a solution to a friction problem, right? We are trying to overcome friction. That's really what it boils down to. So depending on the flow that I have and the flow requirements I have at the other end is going to dictate whether or not I need ⁓ to relay pump. Now, with the the advent of ⁓ large diameter supply line. Which isn't new in today's fire service. ⁓ but this was a big deal back in the seventies and eighties when it was introduced because it dramatically impacted the need whether or not to relay ⁓ for our more bread and butter fires, right? ⁓ with large diameter supply line, you might find that you don't necessarily need to ⁓ perform a relay pumping operation because the fire flows aren't Creating enough friction within the supply layout to necessitate that particular operation. But ⁓ conversely, if we're using smaller diameter hose, or more importantly, in today's modern fire environment, if we have higher fire flows, that is going to necessitate the need for a relay or some sort of pumping operation that utilizes multiple apparatus in a line. ⁓ again, the simplest, the simplest ⁓ way to think about this is What is your friction problem? What is the problem with regards to friction? If I have a lot of friction ⁓ that I need to overcome to get my flow, I need to consider a relay. How about elevation? How much of a role does that play going up like a very, very long hill or something like that? It has a huge, huge impact. ⁓ in fact, one of the one of the projects that I was involved with before I left the city of Charlottesville was ⁓ We had an area in the city called Observatory Hill. And it was a observatory on the top of a mountain that was ⁓ about three thousand foot from the closest fire hydrant. And ⁓ we we kind of got knocked ⁓ from an ISO perspective ⁓ for our ability to deliver water up the hill. So I was tasked with coming up with a plan on how we could ⁓ you know get water to the top of the hill and everything like that. And ⁓ you know. When you map it out and do the math and do everything on flat ground, right? We said to ourselves, okay, well, three thousand foot lay, each of our engines carries a thousand foot. We have four engines staffed, so we have plenty of engines available to lay the hose. What the problem ended up becoming was not necessarily the distance, it was the elevation change. From the closest hydrant to the top of the hill, ⁓ in the most severe point, because it came up from two sides of the mountain. we had over 200 feet of elevation change, and that had a huge impact on the pump discharge pressure, and it required ⁓ either a lower flow rate at the high at the top of the mountain because of the pump pressures that we could achieve, or if we wanted a higher flow, we were going to need more pumpers spaced closer together in order to get that volume up the hill. So To your point, yes, elevation has a huge, huge impact on the design of any relay pumping scenario. And I'm guessing knowing where to get your water, ⁓ whether it is in the rural setting ⁓ or on the, you know, on a more municipal setting where, you know, you you need to know where the big hydrants are, and they're not always going to be close, but they're going to, you know, but you need to know where that water is for the for again, for the flows that you're going to have at the top. Not necessarily the elevation, but just, you know, where wherever it is you're gonna go. ⁓ I've been on them where where we've been on a hill. I've also the ⁓ the industrial fire we had in ⁓ a ⁓ gosh, was it last year? I guess it was. Yeah, it was la ⁓ February twenty twenty five. ⁓ we laid from ⁓ a hydra that was a long way away. ⁓ we had a task force that that handled it. ⁓ and I guess that actually gets into some complexities as well, which I don't know that we'll have time for today. Just setting, you know, having that task force specifically for that purpose to support, you know, the overall operation. But but Bill, ⁓ before we get into any of that kind of stuff, and that that'll that'll be for like if we have time at the end. ⁓ but Bill, what are some of the ⁓ what are some of the myths you've heard against relay pumping? Yeah, mostly ⁓ they they believe it's complicated. There there's more hose you have to put down. There's two operators ⁓ in the rule setting we may not have enough manpower on the scene ⁓ to do a lot of relay pumping, which just so they like to ⁓ take their apparatus set to the side so that their crew can go along with their operator. ⁓ but the ⁓ just like anything else, as long as you practice it, it's not complicated at all. ⁓ and you know sometimes, you know, in ex extreme situations, if the two pumpers are close enough, once they get set, one operator can s can kind of look at watch both of ⁓ I wouldn't advocate for that for every time, but in extreme situations you sure can. And then the communication part of it, they're like, you know, so most people that ⁓ that are against it, they they they don't have means for communicating with each other. Cause the two operators, if you have two of ⁓ you need to have communication between each other. And ⁓ I I've run into a lot of departments that don't have ever not everybody has a radio. So I you know, I teach ⁓ the thumbs up, thumbs down. If they need more pressure, you know, you know, long as they can see each other, they can kind of communicate with hand signals. ⁓ so a lot of the big myths against it is the complication to it and then the communications is the other part. How much is having a ⁓ not necessarily qualified, but ⁓ I think there's a difference between qualified and good. You you know what I'm saying? So like How important is it to have a very good water supply officer in in this instance to overcome just the things you just talked about? Yeah, I always recommend a water supply officer, especially in the role setting, because you know there's there's a lot of information that needs to be put out to all these different departments that are coming in on where to get the water from, what pressures to set things at, and at least you have that one person that you can go to and can give you those answers without tying up a lot of radio traffic. ⁓ so water officers alwa I always recommend it. And and the urban and rural set or urban seg setting, it's not as important because usually it's ⁓ there's a hydrant there and you you know the operators can kind of go with what their intake and discharge pressures are. But when you have, you know, when you're we're dealing with the royal setting, I like to have a water supply officer every time. Yeah, if I can add one thing, right? If if we're being honest, right, and and this might stir the pot a little bit, but You know, you know me, I don't have a problem with that. ⁓ when we talk about reasons against relay pumping, the the obvious one and the big one is a lot of firemen are lazy. They don't want to lay the hose, right? They they I have I have dealt with ⁓ folks, whether it be in training or or reviews of incidents or on actual incidents, where we come up with a million excuses as to why we're not gonna relay pump. When it really boils down to we just don't want to pick up the hose at the end. And at the end of the day, that to me, that's an unacceptable ⁓ reason, right? We carry hose, part of our recruit training is loading hose. That is one of the most basic fundamental jobs of our profession is putting hose back on a rig. It's really not that difficult. ⁓ so you know, to have this aversion to put it on the ground, to me is frankly unacceptable in our profession. But Unfortunately, it exists. So ⁓ I think that's one of the reasons why some organizations stray away from the the relay operation. Nanny, what about those who who are pro relay pumping? Where where where are they ⁓ What are what are the myths there where, you know, like they're they're pro-relay pumping, but they're almost pro for the for the wrong reasons? Well, so, you know, what I have noticed ⁓ in my experience in the fire service, we're we're very ⁓ all or nothing, right? We we like to take an all or nothing approach. And and I've been guilty of it ⁓ in in my ⁓ career as a firefighter. But ⁓ what I what I see is a lot of times fire departments that are We're always going to relay pump or or put p engines in positions to boost pressure and potentially, you know, we're setting up very complex ⁓ systems for ⁓ one or two hand line fire. ⁓ the the issue becomes when I have a bunch of rigs that are engaged in a system and in line. For a small fire, I could potentially create very large pressure spikes at the attack engine that aren't necessary. Right? If the flow is low and there's not a lot of friction, there's no need to boost pressure at the end of the day, whether you know it doesn't matter any other thing, anything else, right? If the flow is low and there's not a lot of friction, I don't need to boost that pressure. So if I am ⁓ just always putting pumpers on hydrants and putting engines in the middle and always doing this. Right, on a one or two hand line fire, my attack engine operator might be sitting here trying to gate things back and idle back and have intake relief valves pop off and this, that, and the other. So I say all that to say, ⁓ it very much is a balance, right? Everything with pump operations is a balance, right? And this is where operators and water supply officers and incident commanders, company officers, everybody, we need to be able to use our brains and say, This is a scenario where it does dictate that I have relay pumping apparatus in the middle to get this volume down to the other end. And you know what? This one line shed fire, right? This this is something that I can deal with hydrant pressure alone. Maybe I don't need to pump the hydrant if if I if if we're not flowing a lot of water. Right. So we we need to be able to use what's between our ears ⁓ to make to make the right decisions. Yeah, I I do remember it was an earlier time. I was a newer pump operator and I we had done just that. You know, the we the ⁓ the the ⁓ the attack engine was ⁓ we've talked about before. ⁓ the attack engine was in front of me. I laid a line up to it. I took the line into my truck and then gave him ⁓ pony length of five inch and supported him with my tank initially, but then once they did ⁓ charge the line, you know, and I I called him, I you know, water supply's been established and but I remember the ⁓ I think it was the chief engineer, not the one who was driving the truck, but the chief engineer of the other company came down and was like, Would you please take your truck out of drive? You know, would you please put it back in neutral? You're killing us, you know, with all the pressure. And you know, and I I mean again, I mean that you know that that makes me sound a little spoiled because, you know, we had decent hydrant pressure that we really didn't need to do, you know, and even though it was a ways away. ⁓ but it's just one, you know, one of those things like, you know, looking between your ears. You know, I would have if I now I was still pretty new, so maybe I didn't want to be necessarily making those decisions yet, you know, but I mean if I was looking at the thing I was like, Holy crap, I'm giving them way too much, you know. And it was, it was exactly that. It was a two line fire. I forget if it was a bedroom fire or what it was. It was probably room and contents with a little extension out, but ⁓ Anyway, sorry, that's my that's my anecdote for the day. Well, no, I'm glad you bring that up, Chris, because right to that point, you know, and I don't want the viewers to to to take what I said the wrong way. I'm not saying that we shouldn't be prepared and set ourselves up for what could happen, right? But to your point, right, you were set up, you were in the in the middle, you were ready to give more water if they needed it. The simple solution in your example is, hey, put the transmission in neutral. Now I have just at a minimum cut out fifty pounds of pressure because the pump is not turning anymore. Right. So so I think that's where we as pump operators, we as instructors, ⁓ we as a fire service on the pump operation side need to need to have these discussions where it's we're not telling you not to be in a position to ⁓ be able to relay pump or to be able to deliver the water. We're just saying, hey, you don't necessarily have to have that pump engaged and building the pressures that aren't needed, right? That's that's really where ⁓ it's important to evaluate all this, right? That that's that's really the primary point. Unless you've hit that hydrant ⁓ multiple times, we use it we don't know what that hydrant flows and what the pressure is that's coming off of it. So it's better be prepared in case it is a low flow hydrant compared to the high flow hydrant. You were in a position to where if they didn't have enough, you could bump it up. And it was a two-stage pump in the ⁓ pressure setting. So Yeah, so there you go, right? But I mean that's that's the one thing when we're talking if if we're going back to like the negatives of relay pumping, like that's the biggest thing. I can't tell you how often I have people approach me and like, hey, I was pumping this fire, I was the attack engine, and I had all this incoming intake pressure. And I radioed to the engine before and said, Hey, what's going on? And they said, Well, we're only pumping at this. And then I'm still have relief valves popping and this, that, and the other. What can I do? What can I do? What can I do to fix that? And and at a certain point, as the attack engine, you can only gate back so far. You can only idle down so much. You can only set your relief valve so low on the intake side, right? So at a certain point, right, we need to be able to tell the guy before us that's feeding us, hey. Take your pump out of gear or or whatever whatever you need to do to stop blasting me to the moon and killing the guys on the hand line, right? ⁓ so so it's important to recognize. So Bill, what about you? ⁓ any any any myths you've heard on on the pro side of this that are just like that that that you know, you hear it and you're like, That's really not the way it works. Well, the biggest one I get is brilliant pump every time. You know, and that's not always the case. Like I Andy had mentioned before, there are times that you don't necessarily need to do the relay pumping. And two is ⁓ you know, we have two pieces of apparatus mate, you know, so maybe you you ⁓ you laid in and was pushing to the first due apparatus. And so that puts both apparatus kind of close to each other or close to the fire scene. And every fireman wants to pull a line off the truck. So They'll have five lines off the first new apparatus and then they come to your truck and they well, let's pull some more, you know, and and you can only flow so much based off of what water source you have. So the big big piece there as far as ⁓ a myth that people think that they can just pull more lines, pull more lines, pull more lines, and that's not always the case. You can only pump as much as your water supply will give you. And two, ⁓ another ⁓ thing is they believe that the more trucks that you have in a system, the more you can flow. And that's not the case either. ⁓ you can only flow as much as the the smallest pump that you have in system. So you can have a 2,000-gallon pumper at the at the fire, but if you're only relay pumping with a thousand GPM pump, guess what you're gonna get? You're only gonna get a thousand gallons. Have either of you ever been told that relay pumping is just for rural departments. Have you guys ever heard of that? I I I forget where I saw it and I threw the question in there because I saw it somewhere, but I mean it it didn't make sense to me because like I said, I mean I I I've I've been in relay pump evolutions like at at, you know, working jobs. ⁓ has has that ever come up with you guys? Have you ever heard that in any of the classes you teach or anything like that? No, I have not. ⁓ Where I work, you know, we're a suburban urban style department and we we've been doing royal relay pumping for a long time. ⁓ there are a lot of people that just don't think to do it. I've never heard anybody say it's only for royal, I guess to answer your question. But ⁓ we relay pump a lot in the suburban area. ⁓ it gives us two pumps and two engines. If s if one goes down, the other one can still supply the crews inside with some water. So that's One of the big reasons we like the relay pump, even in a suburban area. I think it goes back to what we said before on like what are we really calling a relay pump, right? Like what are we calling a relay pumping operation? most of us think of relay pumping operations as, hey, I have twenty five hundred foot on the ground and I need to get water from this pond to that barn that's on fire. ⁓ and and in that case, yeah, you're Probably going to do a scenario like that more frequently in the rural setting. But I mean, if we're actually looking at it from a definition standpoint, right, a lot of urban fire departments are relaying every day, whether it's you know a hundred feet or a thousand foot, right? If you are pumping water from your pump to the intake of another pump, you're doing a relay pumping operation, right? ⁓ so So yeah, I've I personally have never been told like you're only going to do it in the rural setting. I can see where people would take the stance of it's more likely to do the more common traditional definition of a relay where I have six engines ⁓ in a real ⁓ in a relay operation, maybe in the rural setting, but I would not ⁓ I would not take the stance that it's strictly a rural ⁓ operation or even a strictly an urban operation. It's a Fire department pumping operation. I wanted to talk about relay valves and using pumping through a relay valve versus pumping through a truck. As I understand it, you know, ⁓ and this again, this is a little history, I guess, ⁓ for my area. As I understand it, when we first started using the relay valves, it was at a time when there weren't a whole lot of diesel engines being used on the fire grounds. Trucks were overheating, having all kinds of trouble. So it was easy to remove a truck from the relay and put another one in if you were going through the valve. Versus I guess I guess you could still do it the other way, but that that gets a little rough with ⁓ with with ⁓ with heavy hose lines and and things like that. ⁓ so you know, so and as when I first started training on large diameter hose evolutions, that was back when we still had our LaFrance's that did not have large diameter discharges. So it was just it was a it was a convoluted thing. We had this funky valve that had two two and a half inch ⁓ going into a going into a ⁓ a five inch stores and ⁓ so they were we were taking two lines off off the truck. It was a it was a weird thing. But you know I and I remember it was it was clunky to do it with with the valve in the street versus just taking a five inch line off and and going through. In recent years, my understanding is we're we've now switched more toward relaying through the through the truck, using the truck as the valve. To you both, I I don't think this is necessarily an it depends kind of answer, but may maybe it is. But ⁓ but Andy I'll start with you. And do you have do you have like an opinion on this which is which is better going through straight through the truck and using it as a valve versus pumping through the through the humat or not not necessarily the humat. ⁓ valve. Right. Yeah. So ⁓ that's a great question, right? So it it It does depend, right? But ⁓ the simple answer to your question is the the best option is always to go through the rig because you minimize ⁓ your appliance loss and your complication, right? We all know how to get water into our intake. We all know how to get water out of our discharge. So from a simplicity standpoint, yes, it's it it is very easy to tie a rig in the middle and put it in the ⁓ relay and then send water out. To your point, though, if I have to switch the rig out for any reason or anything, that makes it very difficult because I have to shut down the whole flow of water to disconnect the rig, then reconnect, or put another engine in there, right? That can be convoluted. But from an efficiency standpoint and flow standpoint, putting a rig in line is always the best going through the rig. However, the the reason I say it depends is it depends on how your order of arrival comes in, right? If you're in an area where You know that you need a 2,000 foot relay, and ⁓ I only have two engines that are coming initially. Well, I know one's gonna be the attack, I know one's gonna be the supply, and if I wanna put one in the middle, that third new engine might be coming after we already ⁓ establish our water supply. So if we put him in the middle, now we have to shut down to break to tie in. So that's an example where A relay valve is fantastic. If there's going to be a staggering of resources and we know we have a long lay, that's where a relay valve is clutch because hey, put the relay valve there, we can start and then add the third or the fourth or the fifth due engine, whatever it is, into the operation. So like the way I have my pumper set up, ⁓ I actually have a split bed of ⁓ five inch hose in in the hose bed. I carry a thousand foot in one bed and a thousand foot in the other. So I'm carrying two thousand foot. They're not connected in the ⁓ in the middle like a true traditional split bed. So the reason I do it that way is if I were to lay a thousand foot, when I see the last coupling drop, that's my cue as the driver, stop, grab the relay valve, put the relay valve in, and then continue the next leg of the lay. So that way everything is connected. There's a relay valve in the middle. I can get water initially from either the hydrant or the second pumper or whatever. And then if somebody needs to boost me later on, they I've already given them a marker at the thousand foot mark. Yeah, I I agree with Andy. ⁓ anytime you can have the two apparatus in play, ⁓ I would go with that. ⁓ if you are a department that you may be waiting ⁓ for quite a few minutes. ⁓ before that next due apparatus shows up. ⁓ and I would recommend you have a four-way valve and that way when you do hit that hydrant, ⁓ if you have a low flow hydrant, ⁓ it's already set up for that next apparatus to just go ahead and connect into it when they do get there. ⁓ so I'm not against the four way valves at ⁓ by any means, but there are times that you need it and most of the times we're not, you know. ⁓ just depends on your what type water supply system that you have at your your ⁓ area. ⁓ but that's and ⁓ Andy has mentioned multiple times in the past podcast the Columbus changeover. You know if you don't have that four-way valve if you guys go online and watch Andy's videos on the Columbus changeover, you know, that's another way of doing that relay later on in the in the system. If your second do apparatus isn't showing up until late, they can still get the same result without having that four way valve. Speaking of the valves, I've only used I I know that there are neighboring departments that have different four-way valves. I have never had the opportunity outside of like pump school a gajillion years ago, so I've forgotten about it now, I've really only used a Humat. I mean that's that's that's the four way valve that that we've that we've always had. As far as pumping through a valve, what valves have you guys used over the years? ⁓ You know, Bill, I'll start with you on that one. has it always been one type of valve? I mean, you've got Humet, you've got I can think of Hydracyst. That's the other one that that's ⁓ that's pretty popular from what I have heard. ⁓ Bill, what what have you used over the years? I could tell you in this area here, there's not a whole lot of population of ⁓ four-way valves. ⁓ the only ones I have used has been the OASIS through ⁓ TFT. ⁓ I do like the the way it So when I look at most four-way valves, you have to try and figure it out. You know, it's like which way do you hook where where hooks the what, you know? ⁓ where with that particular four-way valve, you know, you can kind of look at it and it's kind of self-explanatory on where those pieces go. ⁓ unfortunately for me, my answer to you is I don't have a whole lot of experience with them, but that is the one that I have used and I like. My my experience is has been ⁓ primarily with the Oasis valve, ⁓ and for the same reasons that that Bill ⁓ highlighted. But I've gone places and used the Humat valve in in ⁓ the middle as an inline relay valve. That is an option. I've also used the AWG valve and and the the Akron style valve. And and what's important for the viewers to understand is that if you have a four-way valve, They all will do the same things. It just is going to look different and your connections might go to different places. But the principles of operation are all the same. ⁓ it just looks different. So you have to familiarize yourself with your particular valve to see how you're going to use it, whether you're using it on the hydrant for traditional four-way valve, boosting the hydrant ⁓ scenarios, or in the middle of a relay as an inline relay valve. And I know there are some fire departments talking on the more rural side. like Mechanicsville, Maryland, they're they're very big. That whole area in Maryland, ⁓ they are really big on using their Humat valves, four-way valves, ⁓ for the rural hitch as their Siamese ⁓ appliance. So that way they just carry one appliance for a multitude of different operations. So ⁓ yeah, it's really just all about getting out and using your equipment, seeing how it works. Two questions here and ⁓ I'm I was looking at ⁓ and looking at ⁓ and I was rethinking them and because they're they're almost the same but but not. ⁓ and you know, the one is what are you what is your advice for departments regarding relay pumping? And then what are your rules of thumb for relay pumping? I think they they sound very much the same, but they are they are different. So for for the for the for the advice, what what you know, I mean for any department, what what what advice do you have for them regarding relay pumping? Andy, I'll start with you for that. I think my biggest piece is ⁓ you know, I my biggest pet peeve is know why you are pumping the pressures you're pumping in a relay operation. ⁓ I know I go to a lot of fire departments and and I get it, firefighters is want pump operations to be pretty streamlined and simple and you know, easy to remember. And I'm all about simplicity, but Not at the sacrifice of knowing the why behind what you're doing. So I go to a lot of fire departments that will say, when we relay pump, we pump at a flat number. We just pump at this number, right? Sometimes it's 50, sometimes it's 75, sometimes it's a hundred. And my question is always, that's not wrong, but why are you doing that? And the answer is usually, well, because I was told to, right? You should ask yourself and ask the department why are we? Pumping at these flat numbers because sometimes that that number may be right on the money, it might be perfect for what you need, but do you know how to compensate for that scenario where it's out of the norm? Meaning that it's a fire that's requiring a higher volume and you have a lot of hose on the ground and 75 pounds isn't going to cut it to get the volume at the other end. So I'm a firm believer in if you have those policies that You know, say that we start at a specific pressure for relay pumping, understand why we're starting at that pressure. Because at 500 gallons a minute under a normal relay, that is ⁓ taking into account the friction loss for 500 gallons a minute at the other end and providing residual intake pressure. And to back that up, know how to determine what the friction loss is or what your pump pressure is going to need to be. if the flow changes, right? ⁓ so that's that's really ⁓ a pet peeve of mine knowing how to calculate that and how to determine the pump pressures at on the fly. What about rules of thumb? My rule of thumb, so ⁓ for most of us, ⁓ if you're using with regards to the the pump pressures, right? ⁓ if you're using four-inch hose, I calculate the friction loss using the condensed Q method for those that remember it. If you don't remember it, Q squared divided by five, right? The easier way to remember that is there are two flows to remember with regards to any relay operation. I always start my flow rate whenever I hook up and start a f ⁓ a flow operation in a relay, I always start at 500 gallons a minute. And the reason being is regardless of what is going on at the fire scene, I start at 500 because I know originally if I'm the first engine showing up and getting the supply line. ⁓ to the attack engine, I know that they are initially operating off of their tank at that attack engine. And unless the rig has specifically spec'd something different, or let's the department spec something different on their attack engine, I know that the tank to pump valve on that ⁓ rig and the tank to pump plumbing is not going to flow more than 500 gallons a minute. So right off the bat, I know that attack engine isn't flowing more than 500 gallons a minute unless it's something special. So if they're flowing a hand line, I'm going to be able to support it. If they're flowing a deck gun, I'm going to be able to support it, right? Off their tank water. But more than likely, they're using their ⁓ they're they're using their tank water for an initial attack, and it's going to be about 150 gallons a minute to start. Well, I know that when I give them water, He is gonna continue to flow that hand line at 150 GPM. He is probably gonna go ahead and put a second line in service, put the backup line in service, because now he has a water supply. And he's gonna wanna refill his tank. All of that combined is gonna be about 500 gallons a minute. So if I just do my math for 500 right off the rip, I'm good to go. So that's where I start. The second number, right, if they call, because normally the fires that I've been on. the the the next radio transmission is not, hey, go ahead and give me seven fifty or a thousand. It's give me more water. Well how much water? I don't know. I just need water. Okay. So I'm a dumb fireman. I just double it. So if we were if I was doing my math for five hundred, now I'm gonna do my math for a thousand, right? Boom. So I just double it. So for for four inch hose, the rules of thumb numbers that I remember is Five pounds per hundred foot for 500 gallons a minute, 20 pounds per hundred foot at a thousand, because when I double flow, friction quadruples, right? So that's pretty easy. For five inch, I do it a little different. Five inch, and and this is a rule of thumb fire ground method. I wrote about it in my book. So if you need that, it's in there. Okay. But for five inch, I use a method called the double drop zero method. I just take my flow rate. I drop the last two zeros, and that's my friction loss per 100 foot. So for 500 gallons a minute, it'd be five pounds per 100 foot. If you do the coefficient method, it comes out to two pounds per 100 foot. Who cares? Right? Doesn't matter. If you do it for a thousand gallons a minute, right, 10 per 100. If you do the coefficient method, it would be 8 per 100. Who cares about that two pounds? So those are the two numbers I remember for relay pumping, right? 500 is start. Thousands where I go to next. If I need to go beyond a thousand, I really need to be thinking about more advanced water supply tactics like parallel supply lines and all kinds of wild stuff. ⁓ that I won't take time up here for. Advice is mainly to watch your intakes constantly. They will change throughout the scene. depending on what they're doing at the fire scene itself, with their attack lines flowing less, flowing more, your intake pressures will change. So Just because you're you're getting ⁓ 50 or 100 pounds in now doesn't mean you're gonna be in five minutes. So, and my with that being said, my rule of thumb is to normally whenever you're pumping a truck, you can kind of set it and kind of forget it. You know, it runs itself. When you're relay pumping, things change. You need to constantly be checking your truck over and over. That is my that's my rule of thumb. And communications is a big piece as well. You gotta be able talk to each other. ⁓ and every department's a little bit different on how they can do that, but that's that is definitely a piece. And then ⁓ the other one was ⁓ establish water supply early. Yeah, when you once you start your relay pump and you've got it started, if you haven't got a water supply, be looking, you know, be getting it ready to set up ASAP. You know, that's be one of your first steps. funny as as you were starting to answer, I was I was actually thinking about a ⁓ pump operator who this is before I even started driving. ⁓ I must have been asking him some questions. And he said exactly that. Once you set it up, it pumps itself. That's what he used to that that's what he used to tell me. He didn't mention the relay part of it. He just said once you set it up, don't worry about it, it pumps itself. So ⁓ important distinction there. You know, you can kind of rely on that a little bit if you're just pumping at a pumping at a job and on a relay you definitely want to be watching constantly. Well guys, we we hit a lot today and I don't wanna I don't want to keep you here too much. We could probably do a part two on this at some point just about relay pumping in general, not necessarily myths. But if there are things that topics you'd like us to hit on please let me know. I'm at Chris dot mccloon at claranne events dot com. We would also like to compile your questions for a future episode, maybe toward the end of the year, where we can where we can have a whole list of your questions that that we can get into. So it's not always us, you know, dictating ⁓ dictating what we're going to be talking about. We would like to hear from you too. So again, that's Chris.mcLoon at clarion events.com. If you would like to ⁓ see previous episodes of ⁓ moving water, they are all up ⁓ archived at www.fireapparatus.com slash podcast. So again, this has been Chris McClun along with Andy Sakadato and Bill Atkins. Have a good one, everyone, and stay safe. Thanks again, guys. Thank you.

Open the transcript file

Hosts and Guests

Nobody is credited on this episode yet.

Credit the people on this episode

Be the first to rate this episode

More episodes

All episodes
  1. Moving Water: Standardization and Rural Firefighting

    Nov 16, 202638 minAudio

    How can rural fire departments improve water supply operations and work more effectively with neighboring agencies? This episode explores the role of apparatus and equipment standardization in rural firefighting,...

    Credit the people on this episode

  2. Managing Fire Apparatus Maintenance and Fleet Downtime

    Nov 9, 202638 minAudio

    Keeping fire apparatus ready for service means navigating parts shortages, complex repairs, long lead times, and tight budgets. This episode explores the challenges facing fire apparatus mechanics and fleet managers,...

    Credit the people on this episode

  3. Don’t Bring the Call Home | The Hidden Biological Contamination Risks Facing First Responders

    Nov 2, 202637 minAudio

    First responders routinely encounter hazards they can see - but some of the most persistent threats are the ones they cannot. Blood and body fluids, infectious materials, contaminated PPE and equipment, and hitchhiking...

    Credit the people on this episode

  4. Beyond the Transaction: Building True Partnerships in Apparatus Purchasing

    Oct 19, 202639 minAudio

    Buying a fire apparatus is rarely a simple transaction. When you drop $1 million on a new pumper, treating the process as an adversarial negotiation or a cold corporate exchange stalls progress and damages outcomes....

    Credit the people on this episode

  5. Be a Partner, Not a Customer: Fire Service Funding and Industry Relationships

    Oct 14, 202620 minAudio

    Fire departments need strong relationships with both elected officials and equipment manufacturers to protect funding, make informed purchasing decisions, and meet operational needs. Chris Mc Loone shares key takeaways...

    Credit the people on this episode