Give Use A Shout HOST A: Dave, a homeowner in Piedmont added a 400 square foot sunroom and called you for a mini-split quote. He had two other quotes already. One was 18,000 BTU, one was 12,000 BTU, you came out and quoted 9,000 BTU. He thought you were sizing too small. HOST B: He was thinking the way you would think about a window unit. More tons, more cooling. Mini-splits do not work that way. They are variable speed. I'm Dave Hartzell at Hartzell's Heat & Air in Kingfisher, Oklahoma. 45 years in the trade, Master HVAC license. On Cool Talk I cover the stuff central Oklahoma homeowners actually need to know about heat, air, and indoor air quality. More episodes: https://hartzellsheatair.com/podcast/ Thanks for tuning in to Hartzell’s Heat & Air - your trusted HVAC experts in Oklahoma and beyond. From Kingfisher to coast-to-coast consulting, we design, install, and maintain smart, efficient systems that deliver year-round comfort. We’re employee-owned, family-run, and powered by 48+ years of experience. Whether it’s AI-powered thermostats, geothermal systems, or classic tune-ups, we deliver upfront pricing, expert care, and warranties that back it all up. 🛠️ Book Online: https://book.housecallpro.com/book/Hartzells-Heat--Air/4a569038b3dc460daf2d5f6497b18351?v2=true 🌐 www.hartzellsheatair.com 📞 (405) 375-4822 🚛 Trane Comfort Specialist • Mitsubishi Diamond Dealer • ClimateMaster Elite 🛡️ VIP Comfort Club • Remote Monitoring • Extended Warranties 📲 Follow us for tips, updates, and real-world installs: YouTube: @hartzellsheatair6003 X: https://x.com/HartzellsHVAC Facebook: facebook.com/hartzellsheatair LinkedIn: Dave Hartzell Built on trust. Backed by warranty. Designed for comfort.
Audio and video play straight from the show's own hosting. PodSubs stores and serves no media.
Chapters
The Big AC Trap
Window Unit Math Explained
Inverter Mini-Splits Run Differently
Short Cycling Kills Comfort
Manual J Finds The Real Load
Heating Math And Heat Pump Physics
Cold Climate Upgrades Worth Paying For
Picking Brands And Vetting Installers
Precision Beats Brute Force
Transcript
From the show. Tap a time to play from there.
SPEAKER_00What if I told you that um spending extra money to buy the absolute most powerful air conditioner on the market is actually the fastest way to make your home totally miserable?
SPEAKER_01Yeah. Sticky, loud, just just awful.
SPEAKER_00Right. Which sounds completely counterintuitive. I mean, we all want a cool house, but to understand why, uh, picture the scenario from our sources today.
SPEAKER_01Okay, let's hear it.
SPEAKER_00So you live in Piedmont and you've just finished putting the touches on this brand new, beautiful, 400 square foot sunroom edition. Sounds nice. It is. Except, you know, the afternoon sun is just beating right through that glass and it's getting incredibly hot.
SPEAKER_01Oh, yeah. The sunrooms can turn into greenhouses real quick.
SPEAKER_00Exactly. So you do the responsible thing, right? You call around, get three different quotes for a mini split air conditioner. Smart. Right. Contractor number one comes in, looks around, says you need an 18,000 BTU unit.
SPEAKER_01Big unit.
SPEAKER_00Yeah. Contractor two says, uh 12,000 BTUs is plenty. And then the third guy walks in, does some math, and quotes you for a tiny 9,000 BTU unit.
SPEAKER_01Aaron Powell And naturally you're looking at that third quote thinking.
SPEAKER_00This guy is crazy. Like why wouldn't I just go with the biggest unit to make absolutely sure the room stays cold?
SPEAKER_01Aaron Powell I mean, it feels like such a natural assumption to make.
SPEAKER_00It really does.
SPEAKER_01Because in almost every other aspect of our lives, we just naturally equate more power with better performance. You know, if you want a faster car, you buy a bigger engine.
SPEAKER_00Aaron Powell Right. Or if you want a brighter room, you get higher wattage bulb.
SPEAKER_01Exactly. We are just so conditioned to think brute force solves everything.
SPEAKER_00Aaron Powell It's so true. But look, our mission for this deep dive is to completely dismantle that instinct when it comes to modern climate control.
SPEAKER_01Yeah. It's a total myth now.
SPEAKER_00We are pulling from a massive stack of sources today. We've got the official ACCA manual J Load Calculation Methodology.
SPEAKER_01Which is heavy reading, but so important.
SPEAKER_00Very heavy. Plus, we have deep in the weeds engineering data from manufacturers like uh Mitsubishi and ACQ, and some brilliant field-tested notes from a 45-year master HVAC technician out in central Oklahoma.
SPEAKER_01The guy has seen it all.
SPEAKER_00He really has. So we're going to decode why our common sense logic about, you know, bigger being better is totally backward here. And how you can actually size an HVAC system without getting ripped off.
SPEAKER_01Aaron Powell What's fascinating here is at the root of this homeowner's confusion, and honestly, the reason those contractors are quoting massive 18,000 BTU units, it stems from this historical legacy. Trevor Burrus, Jr.
SPEAKER_00The old way of doing things.
SPEAKER_01Right. We call it the window unit math. For decades, the crude rule of thumb for just, you know, a standard rattling AC unit in your window was roughly 20 BTUs of cooling power for every square foot of space.
SPEAKER_00Aaron Powell Okay, let's unpack this a bit for anyone who needs a quick refresher. Because a BTU, a British thermal unit, is roughly the amount of heat generated by lighting a single wooden kitchen match.
SPEAKER_01That's a great way to visualize it.
SPEAKER_00Yeah. So when we're talking about a 9,000 BTU unit, we are quite literally talking about grabbing 9,000 matches worth of heat and shoving it out of your room every single hour.
SPEAKER_01Aaron Powell Exactly. And under that old window unit math, a 400 square foot room, you multiply that by 20 and you get 8,000 BTUs.
SPEAKER_00Aaron Powell Right. And since they don't really make an 8,000 BTU mini-split.
SPEAKER_01They don't. Contractors naturally just round up to 12,000. Or like that first guy, they just throw an 18,000 BTU unit on the quote, so they never ever get a callback about the room being too warm.
SPEAKER_00Cover their bases, basically.
SPEAKER_01Exactly. But the critical flaw there is that old school window units and modern mini-splits operate on entirely different mechanical principles. Trevor Burrus, Jr.
SPEAKER_00Right. They aren't the same machine at all.
SPEAKER_01Not even close. Window units and honestly, most traditional central air conditioners are single stage. They're essentially binary.
SPEAKER_00On or off?
SPEAKER_01Exactly. They're either turned on, drawing 100% power, just blasting freezing air, or they are completely shut off. But mini splits utilize variable speed inverter technology. Trevor Burrus, Jr.
SPEAKER_00Okay. Let's unpack how that actually works mechanically, because this is a huge shift. A traditional single-stage compressor is basically like a light switch, right?
SPEAKER_01Yep. Flick it up, flick it down.
SPEAKER_00So driving a car with that technology would mean you either have the gas pedal mash all the way to the floorboard or you turn the engine completely off.
SPEAKER_01Aaron Powell Which would be a terrifying way to drive.
SPEAKER_00Right. You speed up, you coast, you stump the gas again, it's incredibly jerky. But an inverter compressor is more like um like a dimmer switch or cruise control.
SPEAKER_01Aaron Powell That analogy gets right to the physics of it, actually. Instead of just cycling the power on and off, an inverter system physically alters the frequency of the electrical current going to the compressor motor.
SPEAKER_00So it's actively changing speed.
SPEAKER_01Exactly. It spins the compressor faster or slower. The data from our sources shows a standard 9,000 BTU variable speed unit doesn't just sit rigidly at 9,000.
SPEAKER_00Oh wow, okay.
SPEAKER_01Yeah. So on a mild, say 75 degree morning, it can actually modulate its motor way down to run at just 2,500 BTUs.
SPEAKER_00Barely doing anything.
SPEAKER_01Right, just quietly humming, sipping electricity. But then when you hit peak load on a blazing hot afternoon, that same 9,000 BTU unit can actually overclock itself up to 10,500 BTUs to meet the demand.
SPEAKER_00Okay. I'm totally tracking the efficiency argument there, but I want to push back on the comfort side of this for a second.
SPEAKER_01Sure.
SPEAKER_00If the unit is variable speed and it acts like a dimmer switch, what is the actual harm in just buying the 18,000 BTU unit for my small room?
SPEAKER_01I hear this all the time.
SPEAKER_00Because I mean, if it has a dimmer, can't it just run on a super low, quiet setting all day and then cool the room instantly if I throw a party?
SPEAKER_01That is the exact trap consumers fall into. Here's the problem: an inverter system can typically only modulate down to about 25 or maybe 30% of its maximum rated capacity.
SPEAKER_00Oh, so it has a floor.
SPEAKER_01It has a hard floor. If you put an 18,000 BTU unit in a small room, its absolute minimum setting, its lowest possible dimmer level, is still roughly 5,000 BTUs.
SPEAKER_00Oh wow. So on a mild day, even on its lowest setting, it's just way too powerful.
SPEAKER_01Vastly too powerful.
SPEAKER_00Oh, I see the domino effect here. Because the room is small and the unit's minimum blast is so huge, it just satisfies the thermostat instantly.
SPEAKER_01Right. It floods the room with cold air, hits the set temperature in like three minutes, and because it can't modulate down any further, the computer forces it to shut completely off.
SPEAKER_00Otherwise, it would turn the room into a meat locker.
SPEAKER_01Exactly. So it shuts off. Then 10 minutes later, the room warms up a degree, and this massive oversized unit just slams back on again.
SPEAKER_00Just constantly starting and stopping.
SPEAKER_01Yeah, it's called short cycling. And by oversizing the equipment, you've completely defeated the expensive variable speed tech you just paid for. You are forcing a smart system to act like a dumb single-stage window unit.
SPEAKER_00Wow. And beyond just, you know, wearing out the compressor faster with all that stopping and starting, the notes from our HVAC veteran point out a devastating side effect on comfort.
SPEAKER_01Oh, the humidity.
SPEAKER_00Yeah, it completely ruins the system's ability to pull humidity out of the air.
SPEAKER_01And the physics of human comfort relies so heavily on this. Because air conditioning handles two totally different types of cooling.
SPEAKER_00Right.
SPEAKER_01You have sensible cooling, which is just dropping the actual temperature on the thermometer. But then there is latent cooling.
SPEAKER_00Latent cooling, that's the moisture removal.
SPEAKER_01Exactly. Removing the humidity from the air.
SPEAKER_00The stickiness, the part that makes a summer day feel so heavy and gross.
SPEAKER_01Yes. And to remove that humidity, the indoor coil inside the unit has to get incredibly cold. And the air needs to flow over it for a sustained period of time.
SPEAKER_00The sources compare it to setting a glass of ice water on your kitchen counter in July, right?
SPEAKER_01That's a perfect example. It takes time for the ambient moisture in the air to physically condense on the outside of that cold glass.
SPEAKER_00Right. It doesn't happen in two seconds.
SPEAKER_01No. So if your big 18,000 BTU unit is short cycling, dropping the room to 72 degrees in just five minutes and shutting off, the coil gets cold, sure. But the fan stops before that slow condensation process can actually pull water out of the air.
SPEAKER_00Oh man. So the coil never runs long enough to wring the moisture out.
SPEAKER_01Never. So you end up sitting in a room where the thermostat proudly says it's 72 degrees, but the relative humidity is hovering at a swampy 60%.
SPEAKER_00You're sweating, feeling clammy.
SPEAKER_01It's awful. And the tragic part is the homeowner will call the installer furious, complaining that the expensive AC they bought is total garbage.
SPEAKER_00But it's not the brand's fault.
SPEAKER_01Not at all. The unit is operating exactly within the laws of thermodynamics for its size. The real issue is just that a brute force machine cannot handle the nuance of latent cooling in a small space.
SPEAKER_00Okay, so I am officially terrified of accidentally building a sticky humid swamp in my house.
SPEAKER_01It happens more than you'd think.
SPEAKER_00I bet. So if the common sense math of 20 BTUs per square foot is so wildly wrong, what are the professionals actually using to get this right?
SPEAKER_01They turn to a standardized engineering protocol called an ACCA manual J Load Calculation.
SPEAKER_00Manual J.
SPEAKER_01Right. It was fundamentally different from just guessing based on floor space. A manual J is a highly comprehensive thermodynamic model of your specific structure.
SPEAKER_00Here's where it gets really interesting because the sources provide a fantastic real-world example of this calculation.
SPEAKER_01Yeah, that sunroom in Kingfisher, Oklahoma.
SPEAKER_00Right. Let's walk through that because it's incredible how granular this software gets. It isn't just looking at the 400 square feet.
SPEAKER_01Not at all.
SPEAKER_00The HVAC engineer actually has to input the exact R30 value of the ceiling insulation, the R19 fiberglass in the walls.
SPEAKER_01They literally map out the windows. In this case, noting there's 80 square feet of south-facing glass taking a direct hit from the sun.
SPEAKER_00And they even specify if the glass is double pane or single pane.
SPEAKER_01Yep. They calculate the air infiltration through the window seals. They're even required to calculate the latent and sensible heat radiating from two human bodies just sitting on the couch.
SPEAKER_00Wait, really? Body heat.
SPEAKER_01Yes. Just to squeeze every last BTU out of the equation. Every single variable that introduces or removes thermal energy is accounted for.
SPEAKER_00That is wild.
SPEAKER_01And then all those structural details are anchored to local climate data using the 1% extreme design temperature.
SPEAKER_00Okay, what does that mean for Kingfisher?
SPEAKER_01For Kingfisher, Oklahoma, the statistical data requires designing the system to hold its own against a 101 degree afternoon outside.
SPEAKER_00Okay, so after running the insulation, the solar heat gain, the air leakage, the body heat, and that 101 degree ambient temperature through the software.
SPEAKER_01A grand total.
SPEAKER_00Yeah, the actual calculated cooling load for that room comes out to just 7,200 BTUs.
SPEAKER_01It is a stunningly low number. Especially when you realize the first contractor wanted to sell them an 18,000 BTU unit.
SPEAKER_00Over double the requirement.
SPEAKER_01Yeah. The room mathematically only needs 7,200 BTUs of sheet removal on the hottest afternoon of the entire year.
SPEAKER_00It really highlights how absurdly oversized so many residential setups are. The industry rule of thumb for variable speed systems is actually to size the equipment to roughly 1.00 to 1.2 times the peak load, right?
SPEAKER_01Exactly. You want the system running at around 80 or 90 percent of its maximum capacity during that 101 degree stress test. Because the ultimate goal is sustained runtime.
SPEAKER_00So a 7,200 BTU load fits a standard 9,000 BTU unit perfectly.
SPEAKER_01Beautifully. On that blistering summer day, it ramps up to handle the extreme heat. But more importantly, on all the mild days, it can modulate down and run continuously.
SPEAKER_00Stripping that moisture out without short cycling.
SPEAKER_01Exactly. The room stays dry, cool, and comfortable.
SPEAKER_00Okay, so the cooling puzzle makes total sense. The 9,000 BTU unit is the hero for summer. But a sunroom has a completely different personality in January.
SPEAKER_01Oh, absolutely.
SPEAKER_00So if we run a second manual J calculation for the winter heat load in that same Kingfisher room using a design temp of 14 degrees outside, the sources say the heat loss is 9,800 BTUs.
SPEAKER_01This raises an important question, doesn't it?
SPEAKER_00Yeah. If our cooling unit is rated for 9,000 BTUs, but the room needs 9,800 BTUs of heat, the math feels broken. How does a perfectly sized cooling unit handle a winter freeze without leaving you shivering?
SPEAKER_01It totally looks like a mathematical deficit on paper. But it comes down to understanding how a heat pump actually works.
SPEAKER_00Okay, break that down for us.
SPEAKER_01A mini-split is a heat pump. It doesn't create heat by burning fuel or, you know, running electricity over a glowing toaster coil like a space heater.
SPEAKER_00Right.
SPEAKER_01It literally just moves existing thermal energy from one place to another. And the mechanics of the refrigeration cycle heavily favor the heating process.
SPEAKER_00Okay, but wait, the physics of that, if it is 14 degrees outside, where is the heat pump finding any thermal energy out there to move into my house? It feels like trying to squeeze water from a stone.
SPEAKER_01It really does. But it all comes down to the boiling point of the chemical refrigerant moving through the copper pipes.
SPEAKER_00Okay.
SPEAKER_01The refrigerant inside a modern mini split boils at extremely low temperatures, often around negative 50 degrees Fahrenheit.
SPEAKER_00Wait, Maggie or 50.
SPEAKER_01Negative 50.
SPEAKER_00Yeah.
SPEAKER_01So because its boiling point is so incredibly low, 14 degree winter air is actually relatively hot to the refrigerant.
SPEAKER_00Oh my gosh, of course.
SPEAKER_01Yeah. The outdoor fan blows that 14 degree air over the coils, causing that sub-zero liquid refrigerant to instantly boil into a vapor. That phase change absorbs ambient thermal energy from the freezing air outside.
SPEAKER_00That is mind-blowing.
SPEAKER_01Then the compressor takes that vapor and squeezes it incredibly hard. And physics dictates that when you compress a gas, it heats up.
SPEAKER_00Right.
SPEAKER_01So it superheats that vapor, pumps it into the indoor wall unit, and releases that captured heat into your room.
SPEAKER_00That is brilliant. And the notes say that because the compressor motor itself gets hot while it's squeezing the gas, that mechanical waste heat is actually captured and added to the room too.
SPEAKER_01Exactly. Nothing goes to waste. The engineering data shows that a mini split rated to move 9,000 BTUs of heat out of your house in the summer can typically move between 10,500 and 12,000 BTUs of heat into your house in the winter. Wow. So our 9,000 BTU unit, producing up to 12,000 BTUs of heating capacity, effortlessly covers that 9,800 BTU winter load.
SPEAKER_00It'll keep that sunroom perfectly warm down to about 20 degrees inside.
SPEAKER_01Right, down to about 20.
SPEAKER_00But then there's the dreaded 20 degree drop-off. As it gets closer to zero outside, there is eventually just less thermal energy in the air, right?
SPEAKER_01Yeah, a standard compressor simply can't move the fluid fast enough to maintain the heat output when it gets that cold.
SPEAKER_00Which brings us to the cold climate upgrades the industry pushes. Like Mitsubishi's hyperheat technology. What makes those mechanically different from a standard unit?
SPEAKER_01These really advanced flash injection technology. Essentially, when a standard compressor starts struggling in subfreezing temps, a cold climate unit uses a specialized bypass circuit. It injects a mixture of liquid and vapor refrigerant directly back into the compressor mid-cycle. This keeps the compressor cooler and allows it to spin at much, much higher speeds.
SPEAKER_00So it forces it to extract heat even in deep freezes.
SPEAKER_01Exactly. Even when it drops down to negative 13 degrees Fahrenheit.
SPEAKER_00The capability is amazing. But our source notes are very clear that this tech isn't free. Opting for a hyperheat model adds, what, an additional$400 to$800 to the equipment cost?
SPEAKER_01Easily, yeah. And the advice from our HVAC master is purely pragmatic here.
SPEAKER_00Tell us.
SPEAKER_01If the space you are conditioning is your primary living room or a detached office where you work every single day and there is no backup heat, pay the extra$800. You need that guaranteed reliability when a blizzard hits.
SPEAKER_00Totally makes sense.
SPEAKER_01But if this is just a seasonal sunroom that you only wander into occasionally in January, a standard unit that drops off slightly on the three coldest nights of the year is perfectly fine. Keep your money.
SPEAKER_00Great advice. Okay, so knowing the thermodynamics and the variable speed tech gets you halfway there. But the hardware only performs if the physical installation is done right.
SPEAKER_01If we connect this to the bigger picture, the installation is everything. How do you navigate quotes without getting taken advantage of?
SPEAKER_00Right. And the first hurdle is deciding if a mini split is even the right tool. A lot of general contractors will just default to the cheapest option and say, hey, we'll just punch a hole in your central ductwork and run a vent into the new edition.
SPEAKER_01Our Oklahoma source is adamant that this is usually a terrible idea for a sunroom.
SPEAKER_00Because extending central ductwork only works if your existing AC actually has spare capacity, right?
SPEAKER_01Which is incredibly rare. They're usually sized very tightly to the original floor plan. Plus, the edition needs to share the same solar exposure as the rest of the house.
SPEAKER_00And a sunroom doesn't. It has massive glass walls. Its temperature swings wildly independent of the main house.
SPEAKER_01Exactly. Trying to cool it with the main thermostat in a dark hallway is a recipe for disaster. Isolated spaces with wild solar swings are the textbook application for a mini split.
SPEAKER_00Okay, so assuming the mini-split is the correct path, let's navigate the hardware tiers. The market breakdown from the sources is really revealing.
SPEAKER_01It is.
SPEAKER_00At the top, you have the premium tier, brands like Mitsubishi.
SPEAKER_01Where you're paying for top-tier engineering, exceptional cold weather performance, and a robust 12-year warranty.
SPEAKER_00Backed by a huge dealer network. For our 9,000 BTU sunroom, a premium installation runs roughly$4,800.
SPEAKER_01Right. Then you have the mid-tier options, heavily favored by places like Costco, brands like ACQ.
SPEAKER_00The underlying equipment is generally solid, often using compressors licensed from the bigger brands, but you get a shorter warranty and a smaller network of techs if something breaks.
SPEAKER_01And that$9,000 BTU job sits at about$3,200 installed.
SPEAKER_00Finally, the budget. DIY friendly market. Pioneer, Mr. Cool. You can get the installed price down to$2,400 or$2,800, but the sources wave a massive red flag regarding warranty support.
SPEAKER_01It can be incredibly difficult to find a licensed technician willing to work on a budget unit they didn't personally supply.
SPEAKER_00Right. So the strategy is to match the tier to your usage. A daily living space warrants the$4,800 reliability. A garage you tinker in once a month, better fit for the$3,200 unit.
SPEAKER_01Absolutely. But regardless of the price tag, the physical execution by the installer dictates the efficiency.
SPEAKER_00Like placement.
SPEAKER_01Yes. The indoor wall unit must be mounted high up and crucially placed opposite the largest heat source in the room.
SPEAKER_00So in our sunroom, it needs to be blowing cold air directly toward the south facing windows to mix the air effectively.
SPEAKER_01Exactly. And outside, the condenser must be level, clear of obstructions, and shaded if possible. But perhaps the most critical failure point is the copper refrigerant piping.
SPEAKER_00The line sets. The engineering specs are so strict about this. The optimal length is 15 to 25 feet, right?
SPEAKER_01Yes. If an installer gets lazy and runs a line set over 50 feet wrapping around your house, the unit suffers a massive pressure drop.
SPEAKER_00The compressor has to work much harder to push the fluid.
SPEAKER_01And you lose thermal energy along the way. Overly long lines or a sloppy, unlevel mounting job instantly robs you of 10 to 15% of the system's efficiency.
SPEAKER_00And makes it noticeably louder, which no one wants.
SPEAKER_01No. So to shield yourself, our HVAC master source provided this brilliant, straightforward, five-question quote test.
SPEAKER_00The gauntlet.
SPEAKER_01Yes, the gauntlet you put any contractor through. Number one, demand the actual manual J load calculation numbers. Not a guess. The real model.
SPEAKER_00Love it. Number two, ask for the specific heating capacity of the quoted unit at 20 degrees outside.
SPEAKER_01Number three, require them to confirm the planned line, set length will stay under 25 feet.
SPEAKER_00Number four, get the exact warranty details in writing, separating the manufacturer's parts warranty from the installer's labor warranty.
SPEAKER_01And number five, force them to explicitly state whether they are quoting a standard unit or a cold climate model.
SPEAKER_00Because if a contractor just scribbles 12K Mitsubishi,$4,000 on a notepad.
SPEAKER_01That is not a quote. Reputable outfits provide the load calculations, performance data, and installation parameters in writing up front.
SPEAKER_00The shift in perspective here is just profound. We started with a homeowner utterly confused by three wildly different quotes.
SPEAKER_01But by digging into the laden cooling physics.
SPEAKER_00Right, the variable frequency drives and the rigorous math of Emanuel J, the core lesson becomes undeniable.
SPEAKER_01When dealing with modern climate control, bigger is absolutely not better.
SPEAKER_00Precision is better. So what does this all mean? The goal isn't overwhelming brute force. The goal is maximum balance matching the precise capability of the tech to the exact thermodynamic reality of your room.
SPEAKER_01Exactly.
SPEAKER_00And looking at all this data leaves you with a pretty fascinating thought to chew on. Yeah. If our deeply ingrained intuition about more power equals better performance is completely backward when it comes to keeping our homes comfortable, what other areas of our homes or our lives really are we actively sabotaging just by stubbornly applying brute force 20th century logic to nuanced 21st century technology?
Give Use A Shout You know what I notice every single October around here? Folks shut their windows, crank the furnace on for the first time since March, and within a week somebody in the house has a scratchy throat or...
Give Use A Shout I was drinking coffee this morning scrolling through some trade news, and there's a headline about one big company buying another big company that cools data centers. Billions of dollars changing hands....
Give Use A Shout Had a fella out past Dover call me last week asking if his whole street could share one big geothermal loop like he read about somewhere, splitting the cost with his neighbors. I told him that's...
Give Use A Shout I had a fella out on Highway 33 call me last week and ask if he should wait a year to buy a new furnace because he heard some big manufacturer was building a new plant somewhere. I'm Dave Hartzell at...
Give Use A Shout I was reading trade news the other morning, something about a big parts distributor rolling out a fancy new website for commercial buildings and data centers. And I thought, huh, that's a long way from...